Weidmueller MTS 5/12 V T4 B T

Request a price

MTS 5/12 V T4 B T

SKU: 2913810000.0 Category: Brand:

Printed circuit board terminals, PCB terminal, THT solder connection, Pitch in mm (P): 5.00 mm, Number of poles: 12, Tube

Technical Specifications:

Depth 13.2 mm
Depth (inches) 0.52 inch
Height 22.35 mm
Height (inches) 0.88 inch
Height of lowest version 18.85 mm
Width 62.3 mm
Width (inches) 2.453 inch
Net weight 30.578 g
Ambient temperature -50 °C…80 °C
Installation temperature -50 °C to +70 °C
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Product family OMNIMATE 4.0
Wire connection method SNAP IN with push button
Property, clamping point WireReady
Mounting onto the PCB THT solder connection
Conductor outlet direction 180°
Pitch in mm (P) 5 mm
Pitch in inches (P) 0.197 “
Number of poles 12
Pin series quantity 1
Number of rows 1
Solder pin length (l) 3.5 mm
Solder pin dimensions 0.6 x 0.8 mm
Solder eyelet hole diameter (D) 1.3 mm
Solder eyelet hole diameter tolerance (D) + 0,1 mm
Number of solder pins per pole 2
Stripping length 9 mm
Stripping length tolerance min.: 8 mm max.: 10 mm
L1 in mm 55 mm
L1 in inches 2.165 “
Touch-safe protection acc. to DIN VDE 0470 IP 20
Touch-safe protection acc. to DIN VDE 57 106 Safe from finger touch
Protection degree IP20
Insulating material PA 9T
Colour black
Colour chart (similar) RAL 9011
Insulating material group I
Comparative Tracking Index (CTI) ≥ 600
Moisture Level (MSL) 1
UL 94 flammability rating V-0
Contact material Cu-alloy
Contact surface tinned
Tinning type matt
Storage temperature, min. -25 °C
Storage temperature, max. 55 °C
Operating temperature, min. -50 °C
Operating temperature, max. 80 °C
Clamping range, min. 0.34 mm²
Clamping range, max. 4 mm²
Wire connection cross section AWG, min. AWG 12
Wire connection cross section AWG, max. AWG 20
Solid, min. H05(07) V-U 0.5 mm²
Solid, max. H05(07) V-U 2.5 mm²
Flexible, min. H05(07) V-K 0.5 mm²
Flexible, max. H05(07) V-K 4 mm²
w. plastic collar ferrule, DIN 46228 pt 4, min. 0.34 mm²
w. plastic collar ferrule, DIN 46228 pt 4, max. 2.5 mm²
w. wire end ferrule, DIN 46228 pt 1, min. 0.5 mm²
w. wire end ferrule, DIN 46228 pt 1, max. 2.5 mm²
Outer diameter of insulation, max. 4 mm
Clampable conductor Cross-section for conductor connection: nominal: 0.34 mm wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9025770000 Cross-section for conductor connection: nominal: 0.5 mm² wire end ferrule: Stripping length: nominal: 12 mm Recommended wire-end ferrule: 9025870000 Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9004050000 Cross-section for conductor connection: nominal: 0.75 mm² wire end ferrule: Stripping length: nominal: 12 mm Recommended wire-end ferrule: 9025860000 Stripping length: nominal: 10 mm Recommended wire-end ferrule: 0542500000 Cross-section for conductor connection: nominal: 1 mm² wire end ferrule: Stripping length: nominal: 12 mm Recommended wire-end ferrule: 9025950000 Stripping length: nominal: 10 mm Recommended wire-end ferrule: 0282800000 Cross-section for conductor connection: nominal: 1.5 mm² wire end ferrule: Stripping length: nominal: 12 mm Recommended wire-end ferrule: 0635100000 Stripping length: nominal: 10 mm Recommended wire-end ferrule: 0186500000 Cross-section for conductor connection: nominal: 2.5 mm² wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9019160000 Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9004080000
tested acc. to standard IEC 60664-1 IEC 61984
Rated current, min. number of poles (Tu=20°C) 32 A
Rated current, max. number of poles (Tu=20°C) 32 A
Rated current, min. number of poles (Tu=40°C) 32 A
Rated current, max. number of poles (Tu=40°C) 32 A
Rated voltage for surge voltage class / pollution degree II/2 400 V
Rated voltage for surge voltage class / pollution degree III/2 400 V
Rated voltage for surge voltage class / pollution degree III/3 250 V
Rated impulse voltage for surge voltage class/ pollution degree II/2 4 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2 4 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3 4 kV
Wire cross-section, AWG, min. AWG 20
Wire cross-section, AWG, max. AWG 12
Institute (cURus) CURUS
Certificate No. (cURus) E60693
Rated voltage (Use group B / UL 1059) 300 V
Rated voltage (Use group D / UL 1059) 300 V
Rated voltage (Use group F / UL 1059) 420 V
Rated current (Use group B / UL 1059) 18.5 A
Rated current (Use group D / UL 1059) 10 A
Wire cross-section, AWG, min. AWG 20
Wire cross-section, AWG, max. AWG 12
Clearance distance, min. 4 mm
Creepage distance, min. 5.6 mm
Reference to approval values Specifications are maximum values, details – see approval certificate.
IPC conformity Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 “Class 2”. Further claims on the products can be evaluated on request.
Notes Rated current related to rated cross-section & min. No. of poles. P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months

Reviews

There are no reviews yet.

Be the first to review “Weidmueller MTS 5/12 V T4 B T”

Your email address will not be published. Required fields are marked *