Weidmueller SAKG 46 II/GW

Request a price

SAKG 46 II/GW

SKU: 185320000.0 Category: Brand:

Feed-through terminal block, Threaded stud connection, medium yellow, 150 mm², 309 A, 1000 V, Number of connections: 2

Technical Specifications:

Depth 57 mm
Depth (inches) 2.244 inch
Height 106 mm
Height (inches) 4.173 inch
Width 46 mm
Width (inches) 1.811 inch
Net weight 326 g
Storage temperature -25 °C…55 °C
Ambient temperature -5 °C…40 °C
Continuous operating temp., min. -60 °C
Continuous operating temp., max. 130 °C
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 6c
REACH SVHC Lead 7439-92-1
SCIP 999cd67e-471e-4085-8dba-1342fcea86de
Material KrG
Colour medium yellow
UL 94 flammability rating V-0 5VA
Version Stud terminal
End cover plate required Yes
Number of potentials 1
Number of levels 1
Number of clamping points per level 2
Number of potentials per tier 1
Levels cross-connected internally No
PE connection No
Rail TS 32
N-function No
PE function No
PEN function No
Explosion-tested version No
Installation advice Direct mounting
Number of similar terminals 1
Open sides Open
Type of mounting Snap-on
Connection type, additional connection Threaded stud connection
Cable lug to DIN 46234 10…185 mm²
Cable lug to DIN 46235 25 – 150 mm²
Clamping range, max. 185 mm²
Clamping range, min. 10 mm²
Clamping screw M 12
Connection cross-section, stranded, max. 185 mm²
Connection cross-section, stranded, min. 10 mm²
Connection direction on side
Number of connections 2
Stripping length 28 mm
Tightening torque, max. 31 Nm
Tightening torque, min. 14 Nm
Type of connection Threaded stud connection
Wire connection cross section AWG, max. AWG 350 MCM
Wire connection cross section AWG, min. AWG 8
Wire connection cross section, finely stranded, max. 185 mm²
Wire connection cross section, finely stranded, min. 10 mm²
Wire connection cross-section, solid core, max. 185 mm²
Wire connection cross-section, solid core, min. 10 mm²
Certificate No. (CSA) 12400-199
Current size C (CSA) 365 A
Voltage size C (CSA) 600 V
Wire cross section max. (CSA) 300 kcmil
Installation advice Direct mounting
Rail TS 32
Standards IEC 60947-7-1
Wire connection cross section AWG, max. AWG 350 MCM
Wire connection cross section AWG, min. AWG 8
Rated cross-section 150 mm²
Rated voltage 1,000 V
Rated DC voltage 1,000 V
Rated current 309 A
Current at maximum wires 353 A
Standards IEC 60947-7-1
Volume resistance according to IEC 60947-7-x 0.1 mΩ
Rated impulse withstand voltage 8 kV
Power loss in accordance with IEC 60947-7-x 9.89 W
Pollution severity 3

Reviews

There are no reviews yet.

Be the first to review “Weidmueller SAKG 46 II/GW”

Your email address will not be published. Required fields are marked *