Weidmueller LX 15.00/07/90 4.5SN BK BX

Request a price

LX 15.00/07/90 4.5SN BK BX

SKU: 1226510000.0 Category: Brand:

Printed circuit board terminals, 15.00 mm, Number of poles: 7, 90°, Solder pin length (l): 4.5 mm, tinned, black, Clamping yoke connection, Clamping range, max. : 25 mm², Box

Technical Specifications:

Depth 29.1 mm
Depth (inches) 1.146 inch
Height 41.5 mm
Height (inches) 1.634 inch
Height of lowest version 37 mm
Width 103 mm
Width (inches) 4.055 inch
Net weight 120.5 g
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Product family OMNIMATE Power – series LX
Wire connection method Clamping yoke connection
Mounting onto the PCB THT solder connection
Conductor outlet direction 90°
Pitch in mm (P) 15 mm
Pitch in inches (P) 0.591 “
Number of poles 7
Pin series quantity 1
Fitted by customer No
Number of rows 1
Max. adjacent poles per row 10
Solder pin length (l) 4.5 mm
Solder pin dimensions 1.2 x 1.2 mm
Solder eyelet hole diameter (D) 1.6 mm
Solder eyelet hole diameter tolerance (D) + 0,1 mm
Number of solder pins per pole 4
Screwdriver blade 1.0 x 5.5
Screwdriver blade standard DIN 5264
Tightening torque, min. 2.4 Nm
Tightening torque, max. 4 Nm
Clamping screw M 5
Stripping length 16 mm
L1 in mm 90 mm
L1 in inches 3.543 “
Touch-safe protection acc. to DIN VDE 0470 IP 10
Touch-safe protection acc. to DIN VDE 57 106 Safe from finger touch
Protection degree IP20
Volume resistance 0.50 mΩ
Insulating material Wemid (PA)
Colour black
Colour chart (similar) RAL 9011
Insulating material group I
Comparative Tracking Index (CTI) ≥ 600
UL 94 flammability rating V-0
Contact material Cu-alloy
Contact surface tinned
Layer structure of solder connection 1.5…3 µm Ni / 4…6 µm Sn matt
Storage temperature, min. -40 °C
Storage temperature, max. 70 °C
Operating temperature, min. -50 °C
Operating temperature, max. 120 °C
Temperature range, installation, min. -25 °C
Temperature range, installation, max. 120 °C
Clamping range, min. 1.31 mm²
Clamping range, max. 25 mm²
Wire connection cross section AWG, min. AWG 16
Wire connection cross section AWG, max. AWG 4
Solid, min. H05(07) V-U 1.5 mm²
Solid, max. H05(07) V-U 16 mm²
Stranded, min. H07V-R 6 mm²
Stranded, max. H07V-R 25 mm²
Flexible, min. H05(07) V-K 1.5 mm²
Flexible, max. H05(07) V-K 25 mm²
w. plastic collar ferrule, DIN 46228 pt 4, min. 1.5 mm²
w. plastic collar ferrule, DIN 46228 pt 4, max. 16 mm²
w. wire end ferrule, DIN 46228 pt 1, min. 1.5 mm²
w. wire end ferrule, DIN 46228 pt 1, max. 16 mm²
Plug gauge in accordance with EN 60999 a x b; ø 6.9 mm x 6.9 mm
Clampable conductor Cross-section for conductor connection: Type: fine-wired nominal: 4 mm² wire end ferrule: Stripping length: nominal: 15 mm Recommended wire-end ferrule: 9004100000 Cross-section for conductor connection: Type: fine-wired nominal: 6 mm² wire end ferrule: Stripping length: nominal: 15 mm Recommended wire-end ferrule: 0124700000 Cross-section for conductor connection: Type: fine-wired nominal: 10 mm² wire end ferrule: Stripping length: nominal: 15 mm Recommended wire-end ferrule: 0124800000 Cross-section for conductor connection: Type: fine-wired nominal: 16 mm² wire end ferrule: Stripping length: nominal: 15 mm Recommended wire-end ferrule: 0124300000
Reference text Length of ferrules is to be chosen depending on the product and the rated voltage. The outside diameter of the plastic collar should not be larger than the pitch (P)
tested acc. to standard IEC 60664-1 IEC 61984
Rated current, min. number of poles (Tu=20°C) 101 A
Rated current, max. number of poles (Tu=20°C) 101 A
Rated current, min. number of poles (Tu=40°C) 101 A
Rated current, max. number of poles (Tu=40°C) 101 A
Rated voltage for surge voltage class / pollution degree II/2 1,000 V
Rated voltage for surge voltage class / pollution degree III/2 1,000 V
Rated voltage for surge voltage class / pollution degree III/3 1,000 V
Rated impulse voltage for surge voltage class/ pollution degree II/2 6 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2 8 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3 8 kV
Short-time withstand current resistance 3 x 1s mit 1000 A
Rated voltage (Use group B / CSA) 600 V
Rated voltage (Use group C / CSA) 600 V
Rated voltage (Use group D / CSA) 600 V
Rated current (Use group B / CSA) 85 A
Rated current (Use group C / CSA) 85 A
Rated current (Use group D / CSA) 5 A
Wire cross-section, AWG, min. AWG 16
Wire cross-section, AWG, max. AWG 4
Institute (UR) UR
Certificate No. (UR) E60693
Rated voltage (Use group B / UL 1059) 600 V
Rated voltage (Use group C / UL 1059) 600 V
Rated voltage (Use group D / UL 1059) 600 V
Rated current (Use group B / UL 1059) 85 A
Rated current (Use group C / UL 1059) 85 A
Rated current (Use group D / UL 1059) 5 A
Wire cross-section, AWG, min. AWG 16
Wire cross-section, AWG, max. AWG 4
Reference to approval values Specifications are maximum values, details – see approval certificate.
Packaging Box
VPE length 165 mm
VPE width 115 mm
VPE height 84 mm
Test Durability of markings Standard: DIN EN 61984 section 7.3.2 / 09.02 taking pattern from DIN EN 60068-2-70 / 07.96 Test: mark of origin, type identification, pitch, approval marking CSA, approval marking UL, type of material, durability Evaluation: available
Test Clampable cross section Standard: DIN EN 60999 section 6 and 8.1 / 04.94, DIN EN 60947-1 section 8.2.4.5.1 / 12.99 Conductor type: Type of conductor and conductor cross-section: solid 1.5 mm² Type of conductor and conductor cross-section: stranded 1.5 mm² Type of conductor and conductor cross-section: solid 16 mm² Type of conductor and conductor cross-section: stranded 25 mm² Type of conductor and conductor cross-section: AWG 16/1 Type of conductor and conductor cross-section: AWG 16/ stranded Type of conductor and conductor cross-section: AWG 4/1 Type of conductor and conductor cross-section: AWG 4/ stranded Evaluation: passed
Test for damage to and accidental loosening of conductors Standard: DIN EN 60999 section 8.4 / 04.94 Requirement: 0.4 kg Conductor type: Type of conductor and conductor cross-section: solid 1.5 mm² Type of conductor and conductor cross-section: stranded 1.5 mm² Type of conductor and conductor cross-section: AWG 16/7 Type of conductor and conductor cross-section: AWG 16/19 Evaluation: passed Requirement: 4,5 kg Conductor type: Type of conductor and conductor cross-section: AWG 4/ stranded Evaluation: passed
Pull-out test Standard: DIN EN 60999 section 8.5 / 04.94 Requirement: ≥40 N Conductor type: Type of conductor and conductor cross-section: H05V-U1.5 Type of conductor and conductor cross-section: H05V-K1.5 Type of conductor and conductor cross-section: AWG 16/7 Type of conductor and conductor cross-section: AWG 16/19 Evaluation: passed Requirement: ≥ 135 N Conductor type: Type of conductor and conductor cross-section: H05V-R25 Type of conductor and conductor cross-section: H05V-K25 Type of conductor and conductor cross-section: AWG 4/ stranded Evaluation: passed
IPC conformity Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 “Class 2”. Further claims on the products can be evaluated on request.
Notes Additional variants on request Rated current related to rated cross-section & min. No. of poles. Wire end ferrule without plastic collar to DIN 46228/1 Wire end ferrule with plastic collar to DIN 46228/4 P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. The test point can only be used as potential-pickup point. Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months

Reviews

There are no reviews yet.

Be the first to review “Weidmueller LX 15.00/07/90 4.5SN BK BX”

Your email address will not be published. Required fields are marked *