Feed-through terminal, PUSH IN, 50 mm², 1000 V, 150 A, dark beige
Technical Specifications:
| Depth | 80.5 mm |
| Depth (inches) | 3.169 inch |
| Height | 101.5 mm |
| Height (inches) | 3.996 inch |
| Width | 80 mm |
| Width (inches) | 3.15 inch |
| Net weight | 466 g |
| Storage temperature | -25 °C…55 °C |
| Ambient temperature | -5 °C…40 °C |
| Continuous operating temp., min. | -60 °C |
| Continuous operating temp., max. | 130 °C |
| RoHS Compliance Status | Compliant without exemption |
| REACH SVHC | No SVHC above 0.1 wt% |
| Material | Wemid |
| Colour | dark beige |
| Colour of operational elements | orange |
| UL 94 flammability rating | V-0 |
| End cover plate required | No |
| Number of potentials | 4 |
| Number of levels | 1 |
| Number of clamping points per level | 8 |
| Number of potentials per tier | 4 |
| Levels cross-connected internally | No |
| Rail | TS 35 |
| N-function | No |
| PE function | No |
| PEN function | No |
| Explosion-tested version | Yes |
| Open sides | closed |
| Snap-on | Yes |
| Type of fixing | TS 35 |
| Type of mounting | TS 35 |
| Connection type, additional connection | PUSH IN |
| Blade size | 1.0 x 5.5 mm |
| Clamping range, max. | 70 mm² |
| Clamping range, min. | 10 mm² |
| Connection cross-section, stranded, max. | 70 mm² |
| Connection cross-section, stranded, min. | 10 mm² |
| Connection direction | on side |
| Number of connections | 8 |
| Stripping length | 30 mm |
| Twin wire-end ferrules, max. | 10 mm² |
| Twin wire-end ferrules, min. | 4 mm² |
| Type of connection | PUSH IN |
| Wire connection cross section AWG, max. | AWG 2/0 |
| Wire connection cross section AWG, min. | AWG 8 |
| Wire connection cross section, finely stranded, max. | 70 mm² |
| Wire connection cross section, finely stranded, min. | 10 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max. | 50 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min. | 10 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. | 50 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. | 10 mm² |
| Wire connection cross-section, solid core, max. | 16 mm² |
| Wire connection cross-section, solid core, min. | 10 mm² |
| Certificate No. (CSA) | 200039-80069332 |
| Current size B (CSA) | 175 A |
| Current size C (CSA) | 175 A |
| Current size D (CSA) | 5 A |
| Voltage size B (CSA) | 1000 V |
| Voltage size C (CSA) | 1000 V |
| Voltage size D (CSA) | 600 V |
| Wire cross section min. (CSA) | 8 AWG |
| Rail | TS 35 |
| Standards | IEC 60947-7-1 |
| Wire connection cross section AWG, max. | AWG 2/0 |
| Wire connection cross section AWG, min. | AWG 8 |
| Rated cross-section | 50 mm² |
| Rated voltage | 1,000 V |
| Rated DC voltage | 1,500 V |
| Rated current | 150 A |
| Current at maximum wires | 150 A |
| Standards | IEC 60947-7-1 |
| Volume resistance according to IEC 60947-7-x | 0.21 mΩ |
| Rated impulse withstand voltage | 8 kV |
| Power loss in accordance with IEC 60947-7-x | 4.8 W |
| Pollution severity | 3 |
| Surge voltage category | III |
| Certificate No. (cURus) | E60693 |
| Conductor size Factory wiring max. (cURus) | 00 AWG |
| Conductor size Factory wiring min. (cURus) | 8 AWG |
| Conductor size Field wiring max. (cURus) | 00 AWG |
| Conductor size Field wiring min. (cURus) | 8 AWG |
| Current size B (cURus) | 175 A |
| Current size C (cURus) | 175 A |
| Current size D (cURus) | 5 A |
| Voltage size B (cURus) | 1000 V |
| Voltage size C (cURus) | 1000 V |
| Voltage size D (cURus) | 600 V |
| Product information | The max. connectable wire reduces by one wire size if a cross connector is used that has to be mounted in the wire entry. |