Potential distributor terminal, Screw connection, Light Grey, 50 mm², 150 A, 1000 V, Number of connections: 4, Number of levels: 1
Technical Specifications:
| Depth | 45 mm |
| Depth (inches) | 1.772 inch |
| Height | 70 mm |
| Height (inches) | 2.756 inch |
| Width | 35.6 mm |
| Width (inches) | 1.402 inch |
| Net weight | 66 g |
| Storage temperature | -25 °C…55 °C |
| Ambient temperature | -5 °C…40 °C |
| Continuous operating temp., min. | -50 °C |
| Continuous operating temp., max. | 120 °C |
| RoHS Compliance Status | Compliant without exemption |
| REACH SVHC | No SVHC above 0.1 wt% |
| Material | Wemid |
| Colour | Light Grey |
| UL 94 flammability rating | V-0 |
| Certificate No. (ATEX) | CNEX18ATEX0016U |
| Certificate No. (IECEX) | IECEXNEX18.0010U |
| Max. voltage (ATEX) | 880 V |
| Current (ATEX) | 150 A |
| Wire cross section max. (ATEX) | 50 mm² |
| Max. voltage (IECEX) | 880 V |
| Current (IECEX) | 150 A |
| Version | Screw connection |
| End cover plate required | No |
| Number of potentials | 1 |
| Number of levels | 1 |
| Number of clamping points per level | 4 |
| Levels cross-connected internally | No |
| PE connection | No |
| Rail | TS 35 |
| PE function | No |
| Explosion-tested version | Yes |
| Installation advice | Terminal rail / mounting plate |
| Type of mounting | Snap-on |
| Connection type, additional connection | Screw connection |
| Clamping range, max. | 50 mm² |
| Clamping range, min. | 4 mm² |
| Connection cross-section, stranded, max. | 50 mm² |
| Connection direction | on side |
| Number of connections | 4 |
| Type of connection | Screw connection |
| Type of connection 2 | Screw connection |
| Wire connection cross section AWG, max. | AWG 1/0 |
| Wire connection cross section AWG, min. | AWG 10 |
| Wire connection cross section, finely stranded, max. | 0 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max. | 35 mm² |
| Wire connection cross-section, solid core, max. | 50 mm² |
| Installation advice | Terminal rail / mounting plate |
| Number of poles | 1 |
| Rail | TS 35 |
| Standards | IEC 60947-7-1 UL 1059 CSA |
| Wire connection cross section AWG, max. | AWG 1/0 |
| Wire connection cross section AWG, min. | AWG 10 |
| Rated cross-section | 50 mm² |
| Rated voltage | 1,000 V |
| Rated AC voltage | 1,000 V |
| Rated DC voltage | 1,000 V |
| Rated current | 150 A |
| Current at maximum wires | 150 A |
| Standards | IEC 60947-7-1 UL 1059 CSA |
| Volume resistance according to IEC 60947-7-x | 0.21 mΩ |
| Rated impulse withstand voltage | 8 kV |
| Power loss in accordance with IEC 60947-7-x | 4.8 W |
| Pollution severity | 3 |
| Surge voltage category | III |
| Certificate No. (cURus) | E60693 |
| Product information | You will find additional information in the downloadsection of the onlinecatalogue |





Reviews
There are no reviews yet.