Weidmueller BUF 10.16IT/03/180 AG BK BX

Request a price

BUF 10.16IT/03/180 AG BK BX

SKU: 2493400000.0 Category: Brand:

PCB plug-in connector, female plug, 10.16 mm, Number of poles: 3, 180°, PUSH IN with actuator, Clamping range, max. : 16 mm², Box

Technical Specifications:

Depth 39.5 mm
Depth (inches) 1.555 inch
Height 28.9 mm
Height (inches) 1.138 inch
Width 30.48 mm
Width (inches) 1.2 inch
Net weight 34.64 g
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Product family OMNIMATE Power – series BU/SU 10.16
Type of connection Field connection
Wire connection method PUSH IN with actuator
Pitch in mm (P) 10.16 mm
Pitch in inches (P) 0.4 “
Conductor outlet direction 180°
Number of poles 3
L1 in mm 20.32 mm
L1 in inches 0.8 “
Number of rows 1
Pin series quantity 1
Rated cross-section 16 mm²
Touch-safe protection acc. to DIN VDE 57 106 Safe from finger touch
Touch-safe protection acc. to DIN VDE 0470 IP 20
Protection degree IP20
Can be coded Yes
Stripping length 18 mm
Screwdriver blade 0.8 x 4.0
Screwdriver blade standard DIN 5264
Plugging cycles 25
Plugging force/pole, max. 15 N
Pulling force/pole, max. 15 N
Insulating material PA GF
Colour black
Colour chart (similar) RAL 9011
Insulating material group II
Comparative Tracking Index (CTI) ≥ 400
Insulation strength ≥ 10⁸ Ω
UL 94 flammability rating V-0
Contact material Cu-alloy
Contact surface silver-plated
Layer structure of plug contact ≥ 3 µm Ag
Storage temperature, min. -40 °C
Storage temperature, max. 70 °C
Operating temperature, min. -50 °C
Operating temperature, max. 120 °C
Clamping range, min. 2.5 mm²
Clamping range, max. 16 mm²
Wire connection cross section AWG, min. AWG 12
Wire connection cross section AWG, max. AWG 4
Solid, min. H05(07) V-U 2.5 mm²
Solid, max. H05(07) V-U 10 mm²
Stranded, min. H07V-R 10 mm²
Stranded, max. H07V-R 16 mm²
Flexible, min. H05(07) V-K 2.5 mm²
Flexible, max. H05(07) V-K 16 mm²
w. plastic collar ferrule, DIN 46228 pt 4, min. 2.5 mm²
w. plastic collar ferrule, DIN 46228 pt 4, max. 16 mm²
w. wire end ferrule, DIN 46228 pt 1, min. 2.5 mm²
w. wire end ferrule, DIN 46228 pt 1, max. 16 mm²
Clampable conductor Cross-section for conductor connection: Type: fine-wired nominal: 2.5 mm² wire end ferrule: Stripping length: nominal: 20 mm Recommended wire-end ferrule: 9019180000 Stripping length: nominal: 18 mm Recommended wire-end ferrule: 9004090000 Cross-section for conductor connection: Type: fine-wired nominal: 4 mm² wire end ferrule: Stripping length: nominal: 20 mm Recommended wire-end ferrule: 9019210000 Stripping length: nominal: 18 mm Recommended wire-end ferrule: 9004110000 Cross-section for conductor connection: Type: fine-wired nominal: 6 mm² wire end ferrule: Stripping length: nominal: 20 mm Recommended wire-end ferrule: 0565700000 Stripping length: nominal: 18 mm Recommended wire-end ferrule: 9004130000 Cross-section for conductor connection: Type: fine-wired nominal: 10 mm² wire end ferrule: Stripping length: nominal: 21 mm Recommended wire-end ferrule: 0565800000 Stripping length: nominal: 18 mm Recommended wire-end ferrule: 0379300000 Cross-section for conductor connection: Type: fine-wired nominal: 16 mm² wire end ferrule: Stripping length: nominal: 21 mm Recommended wire-end ferrule: 0566000000 Stripping length: nominal: 18 mm Recommended wire-end ferrule: 0375200000
Reference text Length of ferrules is to be chosen depending on the product and the rated voltage.
Rated current, min. number of poles (Tu=20°C) 76 A
Rated current, max. number of poles (Tu=20°C) 71 A
Rated current, min. number of poles (Tu=40°C) 70 A
Rated current, max. number of poles (Tu=40°C) 62 A
Rated voltage for surge voltage class / pollution degree II/2 1,000 V
Rated voltage for surge voltage class / pollution degree III/2 1,000 V
Rated voltage for surge voltage class / pollution degree III/3 1,000 V
Rated impulse voltage for surge voltage class/ pollution degree II/2 8 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2 8 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3 8 kV
Short-time withstand current resistance 3 x 1s with 800A
Institute (cURus) CURUS
Certificate No. (cURus) E60693
Rated voltage (Use group B / UL 1059) 600 V
Rated voltage (Use group C / UL 1059) 600 V
Rated current (Use group B / UL 1059) 51 A
Rated current (Use group C / UL 1059) 51 A
Wire cross-section, AWG, min. AWG 12
Wire cross-section, AWG, max. AWG 6
Reference to approval values Specifications are maximum values, details – see approval certificate.
Packaging Box
VPE length 356 mm
VPE width 185 mm
VPE height 74 mm
Test Durability of markings Standard: IEC 60068-2-70 / 12.95 Test: mark of origin, type identification, pitch, durability, stripping length Evaluation: available
Test Clampable cross section Standard: IEC 60999-1:1999-11 section 9.1, IEC 60947-1:2011-03 section 8.2.4.5.1 Conductor type: Type of conductor and conductor cross-section: stranded 2.5 mm² Type of conductor and conductor cross-section: solid 2.5 mm² Type of conductor and conductor cross-section: stranded 16 mm² Type of conductor and conductor cross-section: solid 10 mm² Type of conductor and conductor cross-section: AWG 12/1 Type of conductor and conductor cross-section: AWG 12/19 Type of conductor and conductor cross-section: AWG 4/1 Type of conductor and conductor cross-section: AWG 4/19 Evaluation: passed
Test for damage to and accidental loosening of conductors Standard: IEC 60999-1:1999-11 section 9.4 bzw. section 8.10 Requirement: 0.7 kg Conductor type: Type of conductor and conductor cross-section: H07V-K2.5 Type of conductor and conductor cross-section: H07V-U2.5 Type of conductor and conductor cross-section: AWG 14/1 Type of conductor and conductor cross-section: AWG 14/19 Evaluation: passed Requirement: 2.9 kg Conductor type: Type of conductor and conductor cross-section: H07V-K16 Type of conductor and conductor cross-section: H07V-U16 Evaluation: passed Requirement: 4,5 kg Conductor type: Type of conductor and conductor cross-section: AWG 4/7 Type of conductor and conductor cross-section: AWG 4/19
Pull-out test Standard: IEC 60999-1:1999-11 section 9.5 Requirement: ≥50 N Conductor type: Type of conductor and conductor cross-section: AWG 14/1 Type of conductor and conductor cross-section: AWG 14/19 Type of conductor and conductor cross-section: H07V-K2.5 Type of conductor and conductor cross-section: H07V-U2.5 Evaluation: passed Requirement: ≥100 N Conductor type: Type of conductor and conductor cross-section: H07V-K16 Type of conductor and conductor cross-section: H07V-U16 Evaluation: passed Requirement: ≥ 135 N Conductor type: Type of conductor and conductor cross-section: AWG 4/7 Type of conductor and conductor cross-section: AWG4/19 Evaluation: passed
IPC conformity Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 “Class 2”. Further claims on the products can be evaluated on request.
Notes Additional variants on request Rated current related to rated cross-section & min. No. of poles. Wire end ferrule with plastic collar to DIN 46228/4 Wire end ferrule without plastic collar to DIN 46228/1 P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. In accordance with IEC 61984, OMNIMATE-connectors are connectors without breaking capacity (COC). During designated use, connectors are not allowed to be engaged or disengaged when live or under load Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months