Weidmueller AAP11 6 LO DL BL

Request a price

AAP11 6 LO DL BL

SKU: 2675320000.0 Category: Brand:

Supply terminal, PUSH IN, 6 mm², 500 V, 41 A, dark beige

Technical Specifications:

Depth 48 mm
Depth (inches) 1.89 inch
Depth including DIN rail 48 mm
Height 85.5 mm
Height (inches) 3.366 inch
Width 8.1 mm
Width (inches) 0.319 inch
Net weight 17 g
Storage temperature -25 °C…55 °C
Ambient temperature -5 °C…40 °C
Continuous operating temp., min. -60 °C
Continuous operating temp., max. 130 °C
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Material Wemid
Colour dark beige
Colour of operational elements blue
UL 94 flammability rating V-0
Certificate No. (ATEX) TUEV17ATEX8030U
Certificate No. (IECEX) IECEXTUR17.0015U
Max. voltage (ATEX) 550 V
Current (ATEX) 33 A
Wire cross section max. (ATEX) 6 mm²
Max. voltage (IECEX) 550 V
Current (IECEX) 33 A
Wire cross section max. (IECEX) 6 mm²
Marking EN 60079-7 Ex ec II C Gc
Ex 2014/34/EU label II 2 G D
End cover plate required Yes
Number of potentials 1
Number of levels 1
Number of clamping points per level 1
Number of potentials per tier 1
Levels cross-connected internally No
PE connection No
Rail TS 35
PE function No
Explosion-tested version Yes
Open sides right
Snap-on Yes
Type of mounting TS 35
Connection type, additional connection PUSH IN
Blade size 1.0 x 5.5 mm
Clamping range, max. 6 mm²
Clamping range, min. 0.34 mm²
Connection cross-section, stranded, max. 6 mm²
Connection cross-section, stranded, min. 0.5 mm²
Connection direction top
Gauge to IEC 60947-1 A5
Number of connections 1
Stripping length 12 mm
Tube length for twin wire-end ferrule Tube length: min.: 10 mm max.: 12 mm Cross-section for conductor connection: nominal: 0.5 mm² Tube length: min.: 10 mm max.: 18 mm Cross-section for conductor connection: nominal: 0.75 mm² Tube length: min.: 12 mm max.: 18 mm Cross-section for conductor connection: min.: 1 mm² max.: 1.5 mm²
Tube length for wire-end ferrule with plastic collar DIN 46228/4 Tube length: min.: 10 mm max.: 12 mm Cross-section for conductor connection: min.: 0.5 mm² max.: 1 mm² Tube length: min.: 10 mm max.: 18 mm Cross-section for conductor connection: nominal: 1.5 mm² Tube length: min.: 12 mm max.: 18 mm Cross-section for conductor connection: nominal: 2.5 mm² Tube length: min.: 10 mm max.: 18 mm Cross-section for conductor connection: min.: 4 mm² max.: 6 mm²
Tube length for wire-end ferrule without plastic collar DIN 46228/1 Tube length: nominal: 10 mm Cross-section for conductor connection: min.: 0.5 mm² max.: 1 mm² Tube length: min.: 10 mm Cross-section for conductor connection: min.: 1.5 mm² max.: 2.5 mm² Tube length: min.: 12 mm max.: 18 mm Cross-section for conductor connection: nominal: 4 mm² Tube length: min.: 10 mm max.: 18 mm Cross-section for conductor connection: min.: 6 mm² max.: 10 mm²
Twin wire-end ferrules, max. 1.5 mm²
Twin wire-end ferrules, min. 0.5 mm²
Type of connection PUSH IN
Type of connection 2 PUSH IN
Wire connection cross section AWG, max. AWG 8
Wire connection cross section AWG, min. AWG 22
Wire connection cross section, finely stranded, max. 6 mm²
Wire connection cross section, finely stranded, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max. 6 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 6 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 0.5 mm²
Wire connection cross-section, solid core, max. 6 mm²
Wire connection cross-section, solid core, min. 0.5 mm²
Number of poles 1
Rail TS 35
Standards In accordance with IEC 60947-7-1
Wire connection cross section AWG, max. AWG 8
Wire connection cross section AWG, min. AWG 22
Rated cross-section 6 mm²
Rated voltage 500 V
Rated AC voltage 500 V
Rated DC voltage 500 V
Rated current 41 A
Current at maximum wires 41 A
Standards In accordance with IEC 60947-7-1
Volume resistance according to IEC 60947-7-x 0.78 mΩ
Rated impulse withstand voltage 6 kV
Power loss in accordance with IEC 60947-7-x 1.31 W
Pollution severity 3
Surge voltage category III

Reviews

There are no reviews yet.

Be the first to review “Weidmueller AAP11 6 LO DL BL”