Analogue isolating amplifier, Input : AC/DC voltage, 0…600 V DC, 0…440 V AC, Output : 0-10 V, 0(4)-20 mA, Signal converter/isolator
Technical Specifications:
| Depth | 114.3 mm |
| Depth (inches) | 4.5 inch |
| Height | 119.2 mm |
| Height (inches) | 4.693 inch |
| Width | 22.5 mm |
| Width (inches) | 0.886 inch |
| Net weight | 140 g |
| Storage temperature | -40 °C…85 °C |
| Operating temperature | -20 °C…60 °C |
| Humidity at operating temperature | 0…95 % (no condensation) |
| Humidity | 5…95 %, no condensation |
| SIL in compliance with IEC 61508 | None |
| MTTF | 140 a |
| RoHS Compliance Status | Compliant with exemption |
| RoHS Exemption (if applicable/known) | 7a, 7cI |
| REACH SVHC | Lead 7439-92-1 |
| SCIP | 2f6dd957-421a-46db-a0c2-cf1609156924 |
| Input resistance | 1 MΩ±5% |
| Input voltage | 0…30 V DC 0…60 V DC 0…300 V DC 0…440 V DC 0…660 V DC 0…60 V AC 0…144 V AC 0…300 V AC 0…440 V AC |
| Number of inputs | 1 |
| Load impedance current | ≤ 500 Ω |
| load impedance voltage | ≥ 10 kΩ |
| Number of outputs | 1 |
| Output current | 0…20 mA 4…20 mA |
| Output voltage, note | 0…10 V |
| Type | active connected control must be passive |
| Accuracy | 0.5 % FSR |
| Configuration | With FDT/DTM software Requires configuration adapter 8978580000 CBX200 USB |
| Nominal power consumption | 2 VA |
| Operating altitude | ≤ 2000 m |
| Power consumption | ≤ 100 mA @ 24 VDC ≤ 120mA @ 24V AC |
| Protection degree | IP20 |
| Rail | TS 35 |
| Step response time | <300 ms |
| Temperature coefficient | ≤ 200 ppm/K |
| Voltage supply | 24…240 VUC (±10%) |
| EMC standards | EN 61326-1 EN 61000-6-2 EN 61000-6-4 |
| Galvanic isolation | between input ⁄ output ⁄ supply |
| Impulse withstand voltage | 4 kV (1.2/50 μs) input – output 4 kV (1.2/50 μs) input / supply 2.5 kV (1.2/50 μs) output / supply |
| Insulation voltage | 1.5 kV AC output / supply 2 kV AC input / output 2 kV AC input / supply |
| Pollution severity | 2 |
| Rated voltage | 600 V input / output 600 V input / supply 300 V output / supply |
| Surge voltage category | III |
| Type of connection | PUSH IN |
| Tightening torque, min. | 0.4 Nm |
| Tightening torque, max. | 0.6 Nm |
| Clamping range, rated connection | 2.5 mm² |
| Clamping range, min. | 0.5 mm² |
| Clamping range, max. | 2.5 mm² |
| Wire connection cross section AWG, min. | AWG 26 |
| Wire connection cross section AWG, max. | AWG 14 |
| Product information | The analogue voltage converter ACT20P-VM-AO-S measures DC or AC voltages. The analogue input signal is linearly converted into an analogue output signal (current or voltage) and galvanically isolated. Features Configuration and monitoring are performed via FDT/DTM-Software „WI-Manager“. Signal and alarm triggering upon exceeding limit values or reverse polarity DC input voltage Front LED indicates operation status 3-way galvanic isolation between input, output and power supply. |