Weidmueller ACT20P-2CI-2CO-ILP-S

Request a price

ACT20P-2CI-2CO-ILP-S

SKU: 7760054124.0 Category: Brand:

Passive isolator, Input : 2 x 0(4) – 20 mA, (loop powered), Output : 2 x 0(4) – 20 mA, Input current loop feed

Technical Specifications:

Depth 114 mm
Depth (inches) 4.488 inch
Height 117.2 mm
Height (inches) 4.614 inch
Width 12.5 mm
Width (inches) 0.492 inch
Net weight 110 g
Operating temperature -20 °C…60 °C
Humidity at operating temperature 0…95 % (no condensation)
Humidity 5…95 %, no condensation
SIL in compliance with IEC 61508 None
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 7a, 7cI
REACH SVHC Lead 7439-92-1
SCIP 2f6dd957-421a-46db-a0c2-cf1609156924
Input current 0(4)…20 mA current loop
Number of inputs 2
Sensor 4- wire sensor (with own power supply) Current source
Voltage drop, current input ≤ 3.5 V @ I input = 20 mA
Load impedance current ≤ 600 Ω
Number of outputs 2
Output current 0…20 mA (if input: 0…20 mA) 4…20 mA (if input: 4…20 mA)
Type active connected control must be passive
Max. switching voltage, AC 0 V
Max. switching voltage, DC 0 V
Rated switching current 0.1 A
Accuracy <0.1 % of end value
Configuration none
Nominal power consumption 2 VA
Operating altitude ≤ 2000 m
Protection degree IP20
Rail TS 35
Step response time ≤ 1 ms
Temperature coefficient ≤ 100 ppm/K
Voltage supply Loop powered, via 4…20 mA input
EMC standards EN 61326-1 EN 61000-6-2 EN 61000-6-4
Galvanic isolation 2-way isolator
Impulse withstand voltage 4 kV (1.2/50 µs)
Insulation voltage 2 kV inputs / outputs
Pollution severity 2
Rated voltage 300 V
Surge voltage category III
Marking II 3 G Ex ec IIC T6 Gc
Type of connection Screw connection
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.6 Nm
Clamping range, rated connection 2.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²
Wire connection cross section AWG, min. AWG 26
Wire connection cross section AWG, max. AWG 12
Product information The ACT20P-2CI-2CO-ILP-S (dual channel) fixed passive isolators isolate analogue standard current source signals. An analogue input current signal is converted linear and galvanic isolated into an analogue output current signal. The device is powered via the input current loop. Features Galvanic 4-way isolation (dual-channel device) between all inputs and outputs.

Reviews

There are no reviews yet.

Be the first to review “Weidmueller ACT20P-2CI-2CO-ILP-S”