Weidmueller ACT20P-UI-AO-DO-LP

Request a price

ACT20P-UI-AO-DO-LP

SKU: 1453210000.0 Category: Brand:

Limit value monitoring, Input : universal U, I, R,ϑ, Output : 4-20 mA, (loop powered), Transistor (Alarm)

Technical Specifications:

Depth 113.6 mm
Depth (inches) 4.472 inch
Height 119.2 mm
Height (inches) 4.693 inch
Width 12.5 mm
Width (inches) 0.492 inch
Net weight 150.632 g
Storage temperature -20 °C…70 °C
Operating temperature -20 °C…60 °C
Humidity at operating temperature 0…95 % (no condensation)
Humidity 10…90 %, no condensation
SIL in compliance with IEC 61508 None
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 7a, 7cI
REACH SVHC Lead 7439-92-1
SCIP 2f6dd957-421a-46db-a0c2-cf1609156924
Cable-length compensation <±0.002 Ω per cable resistance Ω
Influence of the sensor cable resistance 5 Ω @ RTD- Kabel
Input current configurable ± 5 A DC (min. measurement range 0.5 A)
Input resistance, current 40 Ω
Input resistance, voltage > 10 MΩ @ 600 mV 2 MΩ
Input voltage configurable ± 150 mV DC (min. measurement range 15 mV) ± 600 mV DC (min. measurement range 50 mV) ± 12 V DC (min. measurement range 1 V) ± 28 V DC (min. measurement range 2 V) ± 300 V DC (min. measurement range 100 V) 0…300 V AC
Number of inputs 1
Potentiometer 1.2…500 kΩ
Resistance 0…750 Ω 0…1.5 kΩ 0…12 kΩ
Sensor PT100 (2-/3- wire) PT1000 (2-/3- wire) PT200 N120 Cu 10 Thermocouples: B, E, J, K, L, N, R, S, T, U
Sensor supply 0.1 mA / 0.05 mA (depending on measuring range) @ RTD cable
Temperature input range CU10: -100…+260 °C Ni120: -80 °C…+320 °C S: -50…+1768 °C T: -270…+400 °C U: -200…+600 °C PT100 / 200 / 1000: -200 °C…+850 °C B: +100…+1820 °C E: -270…+1000 °C J: -270…+1200 °C K: -270…+1372 °C L: +100…+900 °C N: -180…+1300 °C R: -50…+1768 °C
Type Universal signal isolator / signal amplifier, thermocouple, RTD
Load impedance current ≤ 600 Ω
Type passive connected control must be active
Alarm function configurable Top and bottom limit values, window range Alarm delay: 0…99 s
Hysteresis ≥ 0.1 % of FS
Max. switching voltage, AC 30 V
Number of digital outputs 1
Rated switching current 20 mA
Rated switching voltage ≤ 30 V DC
Type Transistor, open collector
Load resistance current typ. 700 Ω @ 24 V DC
Number of analogue outputs 1
Output current 4…20 mA (current loop)
Signal output direct or inverted
Accuracy <0.1 % of measuring range
Cold-junction compensation error ±1.0°C @ -20° C – 65°C
Configuration With FDT/DTM software Requires configuration adapter 8978580000 CBX200 USB
Nominal power consumption 2 VA
Operating altitude ≤ 2000 m
Protection degree IP20
Rail TS 35
Step response time 450 ms
Temperature coefficient <0.02 °C of measuring range / °C
Voltage supply Output loop powered (10…45 V)
EMC standards EN 61326-1
Galvanic isolation 2-way isolator between input/output
Impulse withstand voltage 4 kV (1.2/50 µs)
Insulation voltage 3.51 kV between input and output
Pollution severity 2
Rated voltage 300 Veff
Surge voltage category III
Type of connection Screw connection
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.6 Nm
Clamping range, rated connection 2.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²
Wire connection cross section AWG, min. AWG 26
Wire connection cross section AWG, max. AWG 12
Product information The ACT20P-UI-AO-DO-LP-X converts and isolates current, voltage, potentiometer and temperature sensor signals (mA, A, mV, V, potentiometer, RTD and TC). The transmit function between the input and output can be set via the configuration program either to predefined functions (x0.5, x, x2) or via a freely definable function table. The device is powered via the output current loop. Features Configuration and monitoring are performed via FDT/DTM-Software „WI-Manager“. The active or passive signal inputs for RTD, TC, potentiometer, mV, V, mA and A are completely electrically isolated. The TC signal input has internal cold-junction compensation. Alarm output (for example, for limit monitoring, sensor error detection and more) 3-way galvanic isolation between input, output/supply and alarm output.

Reviews

There are no reviews yet.

Be the first to review “Weidmueller ACT20P-UI-AO-DO-LP”

Your email address will not be published. Required fields are marked *