Limit value monitoring, Input : 3 phase, Input: 3-phase voltage, Relay output
Technical Specifications:
| Depth | 114.3 mm |
| Depth (inches) | 4.5 inch |
| Height | 117 mm |
| Height (inches) | 4.606 inch |
| Width | 22.5 mm |
| Width (inches) | 0.886 inch |
| Net weight | 140 g |
| Storage temperature | -40 °C…85 °C |
| Operating temperature | -20 °C…60 °C |
| Humidity at operating temperature | 0…95 % (no condensation) |
| Humidity | 5…85 % rel. humidity, no condensation |
| SIL in compliance with IEC 61508 | None |
| RoHS Compliance Status | Compliant with exemption |
| RoHS Exemption (if applicable/known) | 7a, 7cI |
| REACH SVHC | Lead 7439-92-1 |
| SCIP | 2f6dd957-421a-46db-a0c2-cf1609156924 |
| Input resistance, voltage | ≥1,8MΩ |
| Input voltage | 180…500 VAC |
| Number of inputs | 1 |
| Type | 3-phase or 3-phase plus zero conductor AC voltage |
| Number of outputs | 2 |
| Alarm function | Top and bottom limit values, window range Holding function can be activated Phase error Phase sequence Asymmetry Alarm delay: 0…10 s |
| Hysteresis | 5 % @ Phase asymmetry |
| Max. switching voltage, AC | 250 V |
| Max. switching voltage, DC | 30 V |
| Number of digital outputs | 2 |
| Rated switching current | 5 A |
| Switch-on delay | 0…10 s configurable |
| Switching thresholds | Adjustable MIN = 50…100 % x URated input voltage (undervoltage alarm) MAX = 70…120 % x URated input voltage (overvoltage alarm) |
| Type | 2 x 1 – or 1 x 2 changeover contact relay Relay polarity can be inverted |
| Accuracy | 3 % *Urated voltage |
| Configuration | DIP switch and potentiometer |
| Long-term drift | 0.1 % / 10.000 h |
| Nominal power consumption | 1.5 VA |
| Operating altitude | ≤ 2000 m |
| Power consumption | ≤ 3VA <2 W |
| Protection degree | IP20 |
| Rail | TS 35 |
| Repeat accuracy | 2 % *Urated voltage |
| Step response time | ≤ 100 ms |
| Temperature coefficient | 350 ppm/K |
| Voltage supply | supplied from voltage measurement inputs |
| EMC standards | EN 61326-1 |
| Galvanic isolation | between input ⁄ output ⁄ supply ⁄ relay |
| Impulse withstand voltage | 6 kV (input – output) 4 kV (output 1- output 2) 1.2/50 µs |
| Insulation voltage | 2.5 kV (input / output) |
| Pollution severity | 2 |
| Rated voltage | 600 VAC (input – output) 300 VAC (output 1 – output 2) |
| Surge voltage category | III |
| Test voltage | 0.5 kV |
| Type of connection | PUSH IN |
| Tightening torque, min. | 0.4 Nm |
| Tightening torque, max. | 0.6 Nm |
| Clamping range, rated connection | 2.5 mm² |
| Clamping range, min. | 0.5 mm² |
| Clamping range, max. | 2.5 mm² |
| Wire connection cross section AWG, min. | AWG 26 |
| Wire connection cross section AWG, max. | AWG 14 |