Weidmueller ACT20P-AI-AO-AC-P

Request a price

ACT20P-AI-AO-AC-P

SKU: 2495700000.0 Category: Brand:

Analogue isolating amplifier, Input : I/U universal, Output : I/U universal, Signal converter/isolator, 90…264 V AC power supply

Technical Specifications:

Depth 113.7 mm
Depth (inches) 4.476 inch
Height 127.1 mm
Height (inches) 5.004 inch
Width 12.5 mm
Width (inches) 0.492 inch
Net weight 271.516 g
Storage temperature -25 °C…70 °C
Operating temperature -20 °C…60 °C
Humidity at operating temperature 0…95 % (no condensation)
Humidity 10…90 %, no condensation
SIL in compliance with IEC 61508 None
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 7a, 7cI
REACH SVHC Lead 7439-92-1
SCIP 2f6dd957-421a-46db-a0c2-cf1609156924
Input current configurable 0-22 mA (min. measurement range 4 mA)
Input resistance, current 100 Ω
Input resistance, voltage ≥ 1 MΩ
Input voltage configurable 0-11 V (min. measurement range 2 V)
Number of inputs 1
Resolution 3.5 µA / 1.76 mV per bit
Sensor supply 24 V DC
Load impedance current 1 kΩ @ 20 mA
load impedance voltage > 600 Ω @ 10 V
Number of outputs 1
Offset voltage ≤ 20 mV
Output current Adjustable 0…22 mA Output range, min, 4 mA
Output voltage, note Adjustable 0…11 V Output range, min, 2 V
Type active connected control must be passive
Configuration DIP switch Front push-button with reference voltage/current sources
Linearity <± 0.1 % of signal range Typ. ± 0.05 % of signal range
Nominal power consumption 2 VA
Operating altitude ≤ 2000 m
Power consumption, typ. 3 W
Protection degree IP20
Rail TS 35
Step response time 350 ms
Temperature coefficient <0.05 % / °C
Voltage supply 90…264 V AC 47 to 63 Hz
EMC standards EN 61326-1
Galvanic isolation 3-way isolator between input ⁄ output ⁄ supply
Impulse withstand voltage 4 kV (1.2/50 µs)
Insulation voltage 2 kV inputs / outputs
Pollution severity 2
Surge voltage category III
Type of connection PUSH IN
Wire connection cross section AWG, min. AWG 26
Wire connection cross section AWG, max. AWG 14
Wire cross-section, solid, min. 0.2 mm²
Wire cross-section, solid, max. 2.5 mm²
Wire connection cross section, finely stranded, min. 0.2 mm²
Wire connection cross section, finely stranded, max. 2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 2.5 mm²
Product information The universally configurable DC isolating amplifier ACT20P-AI-AO-DC/AC-x isolates and converts analogue signals. An analogue input signal (current or voltage) is linearly converted into an analogue output signal (current or voltage) and galvanically isolated. The power supply is galvanically isolated from input and output (3-way isolation). Features Universally configurable via DIP switches and operating buttonsActive or passive signal inputFront LED indicates operation status3-way galvanic isolation between input, output and power supply