Weidmueller ACT20M-CI-CO-ILP-S

Request a price

ACT20M-CI-CO-ILP-S

SKU: 1176070000.0 Category: Brand:

Passive isolator, Input current loop feed, 1-channel, Input : 0(4)-20 mA, Output : 0(4)-20 mA

Technical Specifications:

Depth 114.3 mm
Depth (inches) 4.5 inch
Height 112.5 mm
Height (inches) 4.429 inch
Width 6.1 mm
Width (inches) 0.24 inch
Net weight 80 g
Storage temperature -40 °C…85 °C
Operating temperature -25 °C…70 °C
Humidity at operating temperature 0…95 % (no condensation)
Humidity 40 °C / 93 % rel. humidity, no condensation
SIL in compliance with IEC 61508 None
MTBF 699 a
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 7a, 7cI
REACH SVHC Lead 7439-92-1
SCIP 2f6dd957-421a-46db-a0c2-cf1609156924
Input current 0…20 mA 4…20mA
Input voltage > 3 V @ 20 mA
Number of inputs 1
Sensor Current source
Voltage drop, current input 1.25 V + 0.015 Vout @25°C
Cut-off frequency (-3 dB) 100 Hz
Load impedance current ≤ 600 Ω @ max 23mA
Number of outputs 1
Output current 0…20 mA 4…20 mA
Type active connected control must be passive
Accuracy <0.1 % of measuring range
Configuration none
Nominal power consumption 1.2 VA
Operating altitude ≤ 2000 m
Power consumption 30 mW
Protection degree IP20
Rail TS 35
Step response time ≤ 5 ms
Temperature coefficient ≤ 0.01 % / °C
Voltage supply Loop powered, via 4…20 mA input
EMC standards EN 61326-1
Galvanic isolation 2-way isolator
Insulation voltage 2.5 kVeff /1 min.
Pollution severity 2
Rated voltage 300 Veff
Surge voltage category II
Installation location Device installed in safe area, zone 2
Marking II 3 G Ex nA IIC T4 Gc
Type of connection Screw connection
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.6 Nm
Clamping range, rated connection 2.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²
Wire connection cross section AWG, min. AWG 30
Wire connection cross section AWG, max. AWG 14
EMC standards EN 61326-1
Standards IEC 61010-1
Product information The ACT20M-CI-CO-ILP-S passive isolator isolates standard analogue current signals.An analogue input current signal is linearly converted to an analogue output current signal and is galvanically isolated. Power is supplied through the input measuring circuit (input loop-powered).
Long specification Standard signal passive isolator1-channel passive isolator in 6.1 mm width input-loop powered,for transmitting and isolating analogue DC current signals 0/4…20 mA.Add-on housing for TS35 rail mountingDimensions: L/W/H 114.3/ 6.1/ 112.5 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20 Input 0/4…20 mAOutput 0/4…20 mALoad resistance < 600 OhmTransmission error < 0,1 % v. E. Limit frequency 100 HzAuxiliary power 0/4…20 mA input current loopPower loss approx. 0.9 WAmbient temperature range -25 °C…+70 °C Isolation EN 61010-1, 2-way isolation up to 2.5 kV AC/DCTest voltage 2.5 kV input against output against auxiliary powerRated voltage 300 V AC/DC at overvoltage category II and pollution degree 2Approvals cULus, FM Div2, ATEX Zone2, DNV, GLType ACT20M-CI-CO-ILP-S
Short specification Standard signal passive isolator1-channel signal passive isolator in 6.1 mm width with input current loop feed,for transmitting and isolating analogue DC current signals from 0/4 to 20 mA