Weidmueller ACT20-FEED-IN-PRO-S

Request a price

ACT20-FEED-IN-PRO-S

SKU: 8965500000.0 Category: Brand:

Supply module, Distributes supply voltage to rail bus, Optional connection of backup supply

Technical Specifications:

Depth 113.6 mm
Depth (inches) 4.472 inch
Height 117.2 mm
Height (inches) 4.614 inch
Width 22.5 mm
Width (inches) 0.886 inch
Net weight 173 g
Storage temperature -20 °C…85 °C
Ambient temperature -20 °C…60 °C
Humidity 40 °C / 95 % rel. humidity, no condensation
SIL in compliance with IEC 61508 None
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 7a, 7cI
REACH SVHC Lead 7439-92-1
SCIP 2f6dd957-421a-46db-a0c2-cf1609156924
Backup power supply 21.6…26.4 V DC
Input current max. 4 A
Input voltage 21.6…26.4 V DC
Number of inputs 2
Supply voltage (input) 21.6…26.4 V DC
Trigger level for the power supply Fault <21 V DC
Number of outputs 1
Output current Equivalent to input current max. 4 A
Output power 96 W
Output voltage, note Input voltage -0.5 V DC / 4 A
Supply voltage (output) 24 V DC
AC power, max. 500 VA / 60 W
Alarm function Device error Failure of power supply backup power supply
Continuous current 2 A
Max. switching voltage, AC 250 V
Type Relay, 1 CO contact
Configuration none
Power consumption <2 W
Power consumption, max. 1 W
Protection degree IP20
Rail TS 35 CH20M Bus
Voltage supply 21.6…26.4 V DC
EMC standards EN 61326-1
Type of connection Screw connection
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.6 Nm
Clamping range, rated connection 2.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²
Wire connection cross section AWG, min. AWG 30
Wire connection cross section AWG, max. AWG 14
Product information The power-feed unit ACT20-FEED-IN-PRO-S distributes the supply voltage for the ACT20 range of devices to the Weidmüller CH20M DIN rail bus. The device also has a connection for a backup power supply. Installation is basically on the Weidmüller CH20M DIN rail bus. Properties The power-feed unit ACT20-FEED-IN-PRO-S detects errors on each of the devices mounted on the Weidmüller CH20M DIN rail and sends a collective message to an external controller via the internal status relay. Two power supplies for the primary and secondary supply (backup) can be optionally connected. A redundant power supply can be set up using two power-feed units and two separate power supplies. The status relay is activated when the following conditions are met: ◊ The supply voltage is on the connection terminals 51 and 52 ◊ The backup supply voltage is on the terminals 53 and 54. If the backup power supply is not required, the supplied jumper needs to be inserted between terminals 52 and 53. ◊ The devices mounted on the Weidmüller DIN rail do not report any errors The device can be used in safe (non-explosive risk) areas or in Zone 2 / Division 2. The operating status of the power supply and the backup power supply is indicated with two green LEDs. A malfunction is indicated with a red LED.

Reviews

There are no reviews yet.

Be the first to review “Weidmueller ACT20-FEED-IN-PRO-S”

Your email address will not be published. Required fields are marked *