Weidmueller FP BOX ON/OFF

Request a price

FP BOX ON/OFF

SKU: 1003260000.0 Category: Brand:

FieldPower® power distribution box, 3-phase AC, IP65, in closed state, glass-fibre reinforced polycarbonate, Insulation displacement connection (IDC), PUSH IN, Maintenance switch

Technical Specifications:

Depth 165 mm
Depth (inches) 6.496 inch
Height 181 mm
Height (inches) 7.126 inch
Width 104 mm
Width (inches) 4.094 inch
Net weight 1,096 g
Storage temperature -40 °C…55 °C
Operating temperature -40 °C…45 °C
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 6c
REACH SVHC Lead 7439-92-1 Potassium perfluorobutane sulfonate 29420-49-3
SCIP 7645f3b1-6db9-495d-9e21-ab1d894aff05
Connection data – contact element power bus Wire connection method: Insulation displacement connection (IDC) Blade size of operating tool: 0.6 x 3.5 mm Number of poles: 5 Conductor connection cross-section, solid, max.: 6 mm² Conductor connection cross-section, solid, min.: 1.5 mm² Conductor connection cross-section, stranded, max.: 6 mm² Conductor connection cross-section, stranded, min.: 2.5 mm² Conductor connection cross-section, finely stranded, max.: 6 mm² Conductor connection cross-section, finely stranded, min.: 2.5 mm² Conductor connection cross-section, finest stranded, max.: 6 mm² Conductor connection cross-section, finest stranded, min.: 2.5 mm²
Connection data – contact element Branch / Feed-in Wire connection method: PUSH IN Blade size of operating tool: 0.6 x 3.5 mm Stripping length: 14 mm Number of poles: 5 Conductor connection cross-section, solid, max.: 6 mm² Conductor connection cross-section, solid, min.: 0.5 mm² Conductor connection cross-section, stranded, max.: 6 mm² Conductor connection cross-section, stranded, min.: 0.5 mm² Conductor connection cross-section, finely stranded, max.: 10 mm² Conductor connection cross-section, finely stranded, min.: 0.5 mm² Conductor connection cross-section, finest stranded, max.: 6 mm² Conductor connection cross-section, finest stranded, min.: 0.5 mm² Conductor connection cross-section with wire end ferrule: Type of wire end ferrule: 12 mm with plastic collar Standard: DIN 46228/1 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: 12 mm with plastic collar Standard: DIN 46228/4 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: 8 mm with plastic collar Standard: DIN 46228/1 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: 8 mm with plastic collar Standard: DIN 46228/4 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: Twin wire-end ferrules Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm²
Insulating material Polycarbonate
Enclosure material glass-fibre reinforced polycarbonate
Silicone No
Colour black
Protection degree IP65 in closed state
UL 94 flammability rating 5VA
Torque for lid screws 2 Nm
Lid attachment TX20 screws
lockable Yes
Type of mounting Screw mounting Fixing lugs
Installation advice Lid screws included
Function Maintenance switch
Can be coded Yes Coded on PE
Voltage type 3-phase AC
Number of poles 5
Number of connections / pole 1
Wire connection method Insulation displacement connection (IDC) PUSH IN
Type of connection, signal M12, A-coded
Rated data acc. to IEC for contact element Voltage type: AC Number of phases: 3 Standard: IEC 60947-7-1, IEC 60947-7-2 Rated voltage: 800 V Rated impulse withstand voltage: 8 kV Rated current (3 loaded poles): 41 A Rated current (4 loaded poles): 25 A
Rated data acc. to IEC for plug-in connector Voltage type: AC Number of phases: 3 Standard: IEC 60947-7-1, IEC 60947-7-2, IEC 61984 Rated voltage: 690 V Rated impulse withstand voltage: 8 kV Rated current (3 loaded poles): 32 A Rated current (4 loaded poles): 25 A
Rated data acc. to UL for contact element Standard: UL 1059 Note: for use with UL-listed TC-ER cables Conductor connection cross-section, AWG, max.: AWG 10 Conductor connection cross-section, AWG, min.: AWG 14 Rated voltage: 600 V Rated current: 30 A
Rated data acc. to UL for plug-in connector Standard: UL 1059 Note: for use with UL-listed TC-ER cables Conductor connection cross-section, AWG, max.: AWG 12 Conductor connection cross-section, AWG, min.: AWG 16 Rated voltage: 600 V Rated current: 20 A
Standards UL 508
auxiliary contact ABB OA1G10
Clamping range, plug, max. 10 mm²
Clamping range, plug, min. 0.75 mm²
Operating voltage 690 V
Pollution severity 3
Power rating AC-23A 7.5 kW
Rated current AC-23A 16 A
Rated short-term current resistance ICW 500 A rms for 1 Second
Switch according to standard IEC 60947-3
Switch type ABB OT16FT3
Terminals – torque 0.8 Nm
Wire connection cross section AWG, max. AWG 8
Wire connection cross section AWG, min. AWG 18