Weidmueller ACT20M-2CI-2CO-OLP-S

Request a price

ACT20M-2CI-2CO-OLP-S

SKU: 1176050000.0 Category: Brand:

Passive isolator, Output current loop powered, 2-channel, Input : 2 x 4-20 mA, Output : 2 x 4-20 mA

Technical Specifications:

Depth 114.3 mm
Depth (inches) 4.5 inch
Height 112.5 mm
Height (inches) 4.429 inch
Width 6.1 mm
Width (inches) 0.24 inch
Net weight 96 g
Storage temperature -40 °C…85 °C
Operating temperature -25 °C…70 °C
Humidity at operating temperature 0…95 % (no condensation)
Humidity 40 °C / 93 % rel. humidity, no condensation
SIL in compliance with IEC 61508 None
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 7a, 7cI
REACH SVHC Lead 7439-92-1
SCIP 2f6dd957-421a-46db-a0c2-cf1609156924
Input current 4…20 mA
Number of inputs 2
Sensor 2-wire transmitter (without own power supply)
Sensor supply 6…35 V (@ 20 mA)
Voltage drop, current input Typical 2.5 V
Cut-off frequency (-3 dB) 100 Hz
Load impedance current ≤600 Ω (channel 1 + 2) @ max 23mA
Number of outputs 2
Output current 4…20 mA
Supply voltage (output) 6…35 V
Type passive connected control must be active
Accuracy <0.05 % of measuring range
Configuration none
Nominal power consumption 1.2 VA
Operating altitude ≤ 2000 m
Power consumption, max. 50 mW
Power consumption, typ. 50 mW
Protection degree IP20
Rail TS 35
Step response time ≤ 5 ms
Temperature coefficient ≤± 0.07 µA x (Δ °C x V supply) @ Tamb 25 °C
Voltage supply Output loop powered
EMC standards EN 61326-1
Galvanic isolation 2-way isolator
Insulation voltage 2.5 kVeff /1 min.
Pollution severity 2
Rated voltage 300 Veff
Surge voltage category II
Installation location Device installed in safe area, zone 2
Marking II 3 G Ex nA IIC T4 Gc
Type of connection Screw connection
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.6 Nm
Clamping range, rated connection 2.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²
Wire connection cross section AWG, min. AWG 30
Wire connection cross section AWG, max. AWG 14
EMC standards EN 61326-1
Standards IEC 61010-1
Product information The passive isolator ACT20M-CI-CO-OLP-S isolates standard analogue current signals. An analogue input current signal is linearly converted into an analogue output current signal and galvanically isolated. Power is supplied through the output measurement circuit (output loop-powered). The passive isolator ACT20M-2CI-2CO-OLP-S offers the same functionality, but has two galvanically isolated channels..
Long specification Standard signal isolating amplifier2-channel signal isolating amplifier in 6.1 mm width output-loop powered,for transmitting and isolating analogue DC current signals 0/4…20 mA.Add-on housing for TS35 rail mountingDimensions: L/W/H 114.3/ 6.1/ 112.5 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20 Input 0/4…20 mAOutput 0/4…20 mALoad resistance < 600 OhmTransmission error < 0,1 % v. E. Limit frequency 100 HzAuxiliary power 0/4…20 mA output current loop Power loss approx. 1.2 W Ambient temperature range -25 °C…+70 °C Isolation EN 61010-1, 2-way isolation up to 2.5 kV AC/DCTest voltage 2.5 kV input against output against auxiliary powerRated voltage 300 V AC/DC at overvoltage category II and pollution degree 2Approvals cULus, FM Div2, ATEX Zone2, DNV, GLType ACT20M-2CI-2CO-OLP-S
Short specification Standard signal isolating amplifier2-channel signal isolating amplifier in 6.1 mm width with output current loop feed,for transmitting and isolating analogue DC current signals from 0/4 to 20 mA