Weidmueller AAP12 10/4X2.5 LO-LI OR

Request a price

AAP12 10/4X2.5 LO-LI OR

SKU: 2503890000.0 Category: Brand:

Modular distribution terminals, PUSH IN, 10 mm², 800 V, 57 A, dark beige

Technical Specifications:

Depth 53.5 mm
Depth (inches) 2.106 inch
Depth including DIN rail 54 mm
Height 89 mm
Height (inches) 3.504 inch
Width 10 mm
Width (inches) 0.394 inch
Net weight 31.093 g
Storage temperature -25 °C…55 °C
Ambient temperature -5 °C…40 °C
Continuous operating temp., min. -60 °C
Continuous operating temp., max. 130 °C
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Material Wemid
Colour dark beige
Colour of operational elements orange
UL 94 flammability rating V-0
Marking EN 60079-7 Ex ec II C Gc
Ex 2014/34/EU label II 2 G D
End cover plate required Yes
Number of potentials 1
Number of levels 1
Number of clamping points per level 5
Number of potentials per tier 1
Levels cross-connected internally No
PE connection No
Rail TS 35
N-function No
PE function No
PEN function No
Explosion-tested version Yes
Installation advice Rail
Open sides right
Type of fixing Snap-on
Type of mounting TS 35
Blade size, additional connection 0.6 x 3.5 mm
Clamping range, further connection, max. 2.5 mm²
Clamping range, further connection, min. 0.14 mm²
Conductor cross-section, flexible plus plastic collar DIN 46228/1, further connection, max. 2.5 mm²
Conductor cross-section, flexible plus plastic collar DIN 46228/1, further connection, min. 0.5 mm²
Conductor cross-section, flexible, further connection, min. 0.5 mm²
Connection direction top
Connection type, additional connection PUSH IN
Cross-section for connected wire, flexible, further connection, max. 2.5 mm²
Cross-section for connected wire, multi-core, further connection, max. 2.5 mm²
Cross-section for connected wire, multi-core, further connection, min. 0.5 mm²
Cross-section for connected wire, solid-core, further connection, max. 2.5 mm²
Cross-section for connected wire, solid-core, further connection, min. 0.5 mm²
Number of connections, additional connection 4
Rated cross-section, further connection 2.5 mm²
Rated current, additional connection 24 A
Stripping length , additional connection 10 mm
Blade size 1.0 x 5.5 mm
Clamping range, max. 16 mm²
Clamping range, min. 0.5 mm²
Connection cross-section, finely stranded, max. 16 mm²
Connection cross-section, stranded, max. 16 mm²
Connection cross-section, stranded, min. 0.5 mm²
Connection direction top
Gauge to IEC 60947-1 A6
Number of connections 1
Stripping length 18 mm
Tube length for twin wire-end ferrule Tube length: nominal: 18 mm Cross-section for conductor connection: min.: 0.75 mm² max.: 1 mm² Tube length: min.: 12 mm max.: 18 mm Cross-section for conductor connection: min.: 1.5 mm² max.: 4 mm²
Tube length for wire-end ferrule with plastic collar DIN 46228/4 Tube length: min.: 18 mm Cross-section for conductor connection: min.: 1.5 mm² max.: 4 mm² Tube length: min.: 12 mm max.: 18 mm Cross-section for conductor connection: min.: 6 mm² max.: 10 mm²
Tube length for wire-end ferrule without plastic collar DIN 46228/1 Tube length: nominal: 18 mm Cross-section for conductor connection: min.: 1.5 mm² max.: 10 mm²
Twin wire-end ferrules, max. 4 mm²
Twin wire-end ferrules, min. 0.5 mm²
Type of connection PUSH IN
Wire connection cross section AWG, max. AWG 6
Wire connection cross section AWG, min. AWG 20
Wire connection cross section, finely stranded, max. 10 mm²
Wire connection cross section, finely stranded, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max. 10 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 10 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 0.5 mm²
Wire connection cross-section, solid core, max. 10 mm²
Wire connection cross-section, solid core, min. 0.5 mm²
Certificate No. (CSA) 200039-70089609
Current size B (CSA) 55 A
Current size C (CSA) 55 A
Current size D (CSA) 5 A
Voltage size B (CSA) 600 V
Voltage size C (CSA) 600 V
Voltage size D (CSA) 600 V
Wire cross section max. (CSA) 6 AWG
Wire cross section min. (CSA) 28 AWG
Installation advice Rail
Rail TS 35
Standards IEC 60947-7-1
Wire connection cross section AWG, max. AWG 6
Wire connection cross section AWG, min. AWG 20
Rated cross-section 10 mm²
Rated voltage 800 V
Rated DC voltage 800 V
Rated current 57 A
Current at maximum wires 57 A
Standards IEC 60947-7-1
Volume resistance according to IEC 60947-7-x 0.56 mΩ
Rated impulse withstand voltage 8 kV
Power loss in accordance with IEC 60947-7-x 1.82 W
Pollution severity 3
Certificate No. (cURus) E60693
Conductor size Factory wiring max. (cURus) 6 AWG
Conductor size Factory wiring min. (cURus) 28 AWG
Conductor size Field wiring max. (cURus) 6 AWG
Conductor size Field wiring min. (cURus) 28 AWG
Current size B (cURus) 55 A
Current size C (cURus) 55 A
Current size D (cURus) 5 A
Voltage size B (cURus) 600 V
Voltage size C (cURus) 600 V
Voltage size D (cURus) 600 V
Product information The applicable safety regulations for the overload and short-circuit of the connected conductors must be followed. The total current of all connected conductors must not exceed the max. load current.

Reviews