Modular distribution terminals, PUSH IN, 2.5 mm², 800 V, 24 A, green
Technical Specifications:
| Depth | 53.5 mm |
| Depth (inches) | 2.106 inch |
| Depth including DIN rail | 54 mm |
| Height | 89 mm |
| Height (inches) | 3.504 inch |
| Width | 5.1 mm |
| Width (inches) | 0.201 inch |
| Net weight | 12.674 g |
| Storage temperature | -25 °C…55 °C |
| Ambient temperature | -5 °C…40 °C |
| Continuous operating temp., min. | -60 °C |
| Continuous operating temp., max. | 130 °C |
| RoHS Compliance Status | Compliant without exemption |
| REACH SVHC | No SVHC above 0.1 wt% |
| Material | Wemid |
| Colour | green |
| UL 94 flammability rating | V-0 |
| Certificate No. (ATEX) | TUEV17ATEX8030U |
| Certificate No. (IECEX) | IECEXTUR17.0015U |
| Max. voltage (ATEX) | 690 V |
| Current (ATEX) | 20 A |
| Wire cross section max. (ATEX) | 2.5 mm² |
| Max. voltage (IECEX) | 690 V |
| Current (IECEX) | 20 A |
| Wire cross section max. (IECEX) | 2.5 mm² |
| Marking EN 60079-7 | Ex ec II C Gc |
| Ex 2014/34/EU label | II 2 G D |
| End cover plate required | Yes |
| Number of potentials | 1 |
| Number of levels | 1 |
| Number of clamping points per level | 5 |
| Levels cross-connected internally | No |
| Rail | TS 35 |
| Explosion-tested version | Yes |
| Installation advice | Rail |
| Connection type, additional connection | PUSH IN |
| Clamping range, max. | 2.5 mm² |
| Clamping range, min. | 0.14 mm² |
| Connection cross-section, stranded, max. | 2.5 mm² |
| Connection cross-section, stranded, min. | 0.5 mm² |
| Number of connections | 5 |
| Stripping length | 10 mm |
| Tube length for twin wire-end ferrule | Tube length: min.: 8 mm max.: 12 mm Cross-section for conductor connection: min.: 0.5 mm² max.: 0.75 mm² |
| Tube length for wire-end ferrule with plastic collar DIN 46228/4 | Tube length: min.: 8 mm max.: 6 mm Cross-section for conductor connection: min.: 0.34 mm² max.: 0.14 mm² Tube length: min.: 12 mm max.: 6 mm Cross-section for conductor connection: min.: 1 mm² max.: 0.5 mm² Tube length: min.: 12 mm max.: 8 mm Cross-section for conductor connection: min.: 2.5 mm² max.: 1.5 mm² |
| Tube length for wire-end ferrule without plastic collar DIN 46228/1 | Tube length: nominal: 5 mm Cross-section for conductor connection: nominal: 0.25 mm² Tube length: min.: 6 mm max.: 10 mm Cross-section for conductor connection: min.: 0.5 mm² max.: 1 mm² Tube length: min.: 7 mm max.: 12 mm Cross-section for conductor connection: min.: 1.5 mm² max.: 2.5 mm² |
| Twin wire-end ferrules, max. | 0.75 mm² |
| Twin wire-end ferrules, min. | 0.5 mm² |
| Type of connection | PUSH IN |
| Wire connection cross section AWG, max. | AWG 12 |
| Wire connection cross section AWG, min. | AWG 28 |
| Wire connection cross section, finely stranded, max. | 2.5 mm² |
| Wire connection cross section, finely stranded, min. | 0.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max. | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min. | 0.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. | 0.5 mm² |
| Wire connection cross-section, solid core, max. | 2.5 mm² |
| Wire connection cross-section, solid core, min. | 0.5 mm² |
| Installation advice | Rail |
| Rail | TS 35 |
| Standards | IEC 60947-7-1 |
| Wire connection cross section AWG, max. | AWG 12 |
| Wire connection cross section AWG, min. | AWG 28 |
| Rated cross-section | 2.5 mm² |
| Rated voltage | 800 V |
| Rated voltage to adjoining terminal | 800 V |
| Rated DC voltage | 800 V |
| Rated current | 24 A |
| Current at maximum wires | 24 A |
| Standards | IEC 60947-7-1 |
| Volume resistance according to IEC 60947-7-x | 1.33 mΩ |
| Power loss in accordance with IEC 60947-7-x | 0.77 W |





Reviews
There are no reviews yet.