Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
Technical Specifications:
| Depth | 113.6 mm |
| Depth (inches) | 4.472 inch |
| Height | 117.2 mm |
| Height (inches) | 4.614 inch |
| Width | 17.5 mm |
| Width (inches) | 0.689 inch |
| Net weight | 134 g |
| Storage temperature | -40 °C…85 °C |
| Humidity | 5…95 %, no condensation |
| SIL in compliance with IEC 61508 | None |
| MTTF | 130 a |
| RoHS Compliance Status | Compliant with exemption |
| RoHS Exemption (if applicable/known) | 7a, 7cI |
| REACH SVHC | Lead 7439-92-1 |
| SCIP | 2f6dd957-421a-46db-a0c2-cf1609156924 |
| Input frequency | AC: 15…400 Hz (true root mean square) AC: 50 Hz (arithmetic average) |
| Input measurement range | configurable 0…1/5/10 A AC (RMS) or DC |
| Input signal | Power cable can be connected to the terminals |
| Load impedance current | ≤ 600 Ω |
| Max. switching voltage, AC | 250 V |
| Max. switching voltage, DC | 24 V |
| Rated switching current | 2 A |
| Type | Relay, 1 CO contact Process alarms (4x) with hysteresis with alarm delay (configurable) 0…180 s |
| Load resistance current | ≤ 600 Ω |
| Load resistance voltage | ≥ 10 kΩ |
| Output current | Adjustable 0…20 mA 4…20 mA -20…+20 mA |
| Output voltage | Adjustable 0…10 V 2…10 V 0…5 V 1…5 V -5…+5 V -10…+10 V |
| Type (analogue output) | Voltage and current output (configurable) |
| Switching current | 5 A |
| Accuracy | ≤ ±0.3 % @ 1 A / 5 A ≤ ±0.6 % @ 10 A |
| Configuration | for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis via gateway (ACT20C-GTW-100-MTCP-S) With FDT/DTM software DIP switch and potentiometer |
| Nominal power consumption | 3 VA |
| Power consumption, max. | 2.2 W |
| Protection degree | IP20 |
| Rail | TS 35 |
| Step response time | ≤ 300 ms (RMS) ≤ 60 ms (AA) |
| Temperature coefficient | ≤ ±100 ppm⁄K @ -25…+55 °C ≤ ±200 ppm/K @ +55…+70 °C |
| Voltage supply | 24 V DC ± 30 % |
| EMC standards | IEC 61326-1 |
| Galvanic isolation | 4-way isolator; between input ⁄ output ⁄ supply ⁄ relay |
| Impulse withstand voltage | 6 kV (1.2/50 µs) |
| Pollution severity | 2 |
| Rated voltage | 300 V ACrms |
| Surge voltage category | III |
| Test voltage | 4 kV |
| Type of connection | Screw connection |
| Tightening torque, min. | 0.5 Nm |
| Tightening torque, max. | 3.5 Nm |
| Clamping range, rated connection | 1.5 mm² |
| Clamping range, min. | 0.5 mm² |
| Clamping range, max. | 2.5 mm² |
| Wire connection cross section AWG, min. | AWG 30 |
| Wire connection cross section AWG, max. | AWG 14 |
| Wire cross-section, solid, min. | 0.5 mm² |
| Wire cross-section, solid, max. | 2.5 mm² |





Reviews