Gateway for ACT20C station, Configurable, Modbus TCP/IP, Distributes supply voltage to rail bus
Technical Specifications:
| Depth | 113.6 mm |
| Depth (inches) | 4.472 inch |
| Height | 117.2 mm |
| Height (inches) | 4.614 inch |
| Width | 22.5 mm |
| Width (inches) | 0.886 inch |
| Net weight | 150 g |
| Storage temperature | -40 °C…85 °C |
| Operating temperature | -25 °C…60 °C |
| Humidity | 5…95 %, no condensation |
| SIL in compliance with IEC 61508 | None |
| MTTF | 160 a |
| RoHS Compliance Status | Compliant with exemption |
| RoHS Exemption (if applicable/known) | 7a, 7cI |
| REACH SVHC | Lead 7439-92-1 |
| SCIP | 2f6dd957-421a-46db-a0c2-cf1609156924 |
| Addressing | DHCP or manual adjustment |
| Interface | Communication via CH20M rail bus with all current measuring transducers (ACT20C-CMT-x) |
| Number of devices on the bus, max. | 16 |
| Protocol | Modbus/TCP DHCP Server/Client |
| Configuration | With FDT/DTM software DHCP |
| Nominal power consumption | 3 VA |
| Power consumption, max. | 1.5 W |
| Protection degree | IP20 |
| Rail | TS 35 |
| Voltage supply | 18.0 … 31.2 V DC |
| EMC standards | IEC 61326-1 |
| Impulse withstand voltage | 0,5 kV (1.2/50 μs) |
| Pollution severity | 2 |
| Rated voltage ⁄ test voltage Ethernet interface to supply ⁄ functional earth to supply ⁄ Ethernet interface | 30 V AC RMS |
| Surge voltage category | II |
| Test voltage | 1.1 kV |
| Type of connection | Screw connection |
| Tightening torque, min. | 0.5 Nm |
| Tightening torque, max. | 3.5 Nm |
| Clamping range, rated connection | 1.5 mm² |
| Clamping range, min. | 0.5 mm² |
| Clamping range, max. | 2.5 mm² |
| Wire connection cross section AWG, min. | AWG 30 |
| Wire connection cross section AWG, max. | AWG 14 |
| Wire cross-section, solid, min. | 0.5 mm² |
| Wire cross-section, solid, max. | 2.5 mm² |
| Wire connection cross section, finely stranded, min. | 0.5 mm² |
| Wire connection cross section, finely stranded, max. | 2.5 mm² |
| Product information | The ACT20C-GTW-100-MTCP-S gateway is a modbus TCP slave in accordance with IEC 61158. It connects ACT20C devices to an Ethernet network for diagnostic, configuration and status monitoring purposes. Properties RJ45 port with Ethernet TCP/IP Jack socket for direct point-to-point communication via a CBX200 USB adapter Configuration using the standard FDT/DTM Station management with “Plug & Produce” and “Hot Swapping” Operational status and error display on a front panel LED according to NE44, NE107 |