Weidmueller ACT20M-UI-AO-S

Request a price

ACT20M-UI-AO-S

SKU: 1176030000.0 Category: Brand:

Temperature converter, Analogue isolating amplifier, Input : universal U, I, R,ϑ, Output : I / U

Technical Specifications:

Depth 114.3 mm
Depth (inches) 4.5 inch
Height 112.5 mm
Height (inches) 4.429 inch
Width 6.1 mm
Width (inches) 0.24 inch
Net weight 80 g
Storage temperature -40 °C…85 °C
Operating temperature -25 °C…70 °C
Humidity at operating temperature 0…95 % (no condensation)
Humidity 40 °C / 93 % rel. humidity, no condensation
SIL in compliance with IEC 61508 None
MTBF 176 a
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 7a, 7cI
REACH SVHC Lead 7439-92-1
SCIP 2f6dd957-421a-46db-a0c2-cf1609156924
Input current configurable 0…20 mA 4…20mA
Input resistance, voltage > 10 MΩ
Input voltage configurable 0(2)…10 V 0(1)…5 V 0…1 V DC 0,2…1 V DC
Number of inputs 1
Potentiometer 10…100 kΩ
Resistance 0…10 kΩ
Sensor Thermocouples: B / C / E / J / K / L / N / R / S / T / W3 / W5- 200…+ 2300 °C depending on thermocouple RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000 2-/3-/4-wire
Sensor supply > 15 V DC at 20 mA
Temperature input range Configurable min. measurement range 10°C (RTD) N: (-180…+1300 °C) R: (-50…+1760 °C) S: (-50…+1760 °C) T: (-200…+400 °C) U: (-200…+600 °C) W3: (0…+2300 °C) W5: (0…+2300 °C) LR: (-200…+800 °C) Details under Downloads “Measuring range Table ACT20M-UI-AO” min. measurement range 50°C (TC) PT100: -200°C…850 °C NI100: -60°C…+250 °C TC type: B (0…+1820 °C) E: (-100…+1000 °C) J: (-100…+1200 °C) K: (-180…+1372 °C) L: (-200…+900 °C)
Voltage drop, current input <3 V
Cut-off frequency (-3 dB) 100 Hz
Load impedance current ≤ 600 Ω @ max 28mA
load impedance voltage ≥ 10 kΩ
Number of outputs 1
Output current configurable 0…20 mA 4…20 mA 20…0 mA 20…4 mA downscale (3,5 mA) upscale (23 mA) in case of sensor error
Output voltage, note configurable 0(2)…10 V 0(1)…5 V 0(0,2)…1 V 1…(0,2)0 V 5…(1)0 V 10…(2)0 V downscale (0 V) upscale (11 V) in case of sensor error
Type active connected control must be passive
Wire break detection Yes, if using RTD / POT / TC
Accuracy <0.1 % of measuring range
Configuration With FDT/DTM software Requires configuration adapter 8978580000 CBX200 USB
Nominal power consumption 1.2 VA
Operating altitude ≤ 2000 m
Power consumption, max. 1.2 W
Power consumption, typ. 0.84 W
Protection degree IP20
Rail TS 35
Step response time 400 ms (10…90%) @ U/I 1 s @ temp
Temperature coefficient ≤ 0.01 % / °C
Voltage supply 24 V DC ±30 % at terminal or via CH20M rail bus
EMC standards IEC 61326-1
Galvanic isolation 3-way isolator
Insulation voltage 2.5 kVeff /1 min.
Pollution severity 2
Rated voltage 300 Veff
Surge voltage category II
Installation location Device installed in safe area, zone 2
Marking II 3 G Ex nA IIC T4 Gc
Type of connection Screw connection
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.6 Nm
Clamping range, rated connection 2.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²
Wire connection cross section AWG, min. AWG 30
Wire connection cross section AWG, max. AWG 14
EMC standards IEC 61326-1
Standards IEC 61010-1
Long specification Universal measurement isolating transformeruniversal measurement isolating transformer in 6.1 mm width with external power and sensor power supplyto transmit and isolate analogue DC currents 0/4 to 20 mA / voltages 0/2 to 10 V, 2-/3-/-4- wire RTD, resistances, potentiometers and thermocouples according toIEC584. The module can be programmed via software using standard FDT/DTM tools.Add-on housing for TS35 DIN rail installationDimensions: L/W/H 114.3/ 6.1/ 112.5 mmScrew connection / nominal cross-section 2.5 mm2Protection degree: IP20 Input0/4…20 mA 0/2…10 V PT100, PT1000, Ni100, Ni1000 Resistance/ potentiometer 10 Ohm…10 kOhm Thermocouples type B, E, J, K, L, LR, N, R, S, T, U, W3, W5Sensor supply > 15 VDC at 20 mAOutput 0/4…20 mA 0/2…10 VLoad resistance 10 kOhm/ voltageTransmission errorStep response time10…90 % Auxiliary power 24 VDC +/- 30 %Power loss approx. 1.2 WAmbient< 0,1 % v. E. (DC, RTD)temperature range -25 °C…+70 °C Isolation EN 61010-1, 3-way isolation up to 2.5 kV AC/DC of all circuits against each otherTest voltage 2.5 kV input against output against auxiliary powerRated voltage 300 V AC/DC at overvoltage category II and pollution degree 2Approvals cULus, FM Div2, ATEX Zone2, DNV, GLType ACT20M-UI-AO-S
Short specification Universal measurement isolating transformeruniversal measurement isolating transformer in 6.1 mm width with external power and sensor power supply for transmitting and isolating analogue DC currents 0/4 to 20 mA / voltages 0/2 to 10 V, 2-/3-/-4- wire RTD, resistances, potentiometers and thermocouples according to IEC584. The component can be programmed via software using standard FDT/DTM tools.

Reviews

There are no reviews yet.

Be the first to review “Weidmueller ACT20M-UI-AO-S”

Your email address will not be published. Required fields are marked *