Weidmueller ACT20P-BRIDGE-P

Request a price

ACT20P-BRIDGE-P

SKU: 2456820000.0 Category: Brand:

Measuring bridge converter, Input : Resistance measuring bridge, Output : 0(4)-20 mA, 0-10 V

Technical Specifications:

Depth 113.6 mm
Depth (inches) 4.472 inch
Height 127.1 mm
Height (inches) 5.004 inch
Width 22.5 mm
Width (inches) 0.886 inch
Net weight 205 g
Storage temperature -40 °C…85 °C
Operating temperature -20 °C…60 °C
Humidity at operating temperature 0…95 % (no condensation)
Humidity 10…90 %, no condensation
SIL in compliance with IEC 61508 None
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 7a, 7cI
REACH SVHC Lead 7439-92-1
SCIP 2f6dd957-421a-46db-a0c2-cf1609156924
Bridge sensitivity 1.0 mV / V to 5.0 mV / V
Bridge supply voltage 5 V or 10 V
Input signal ±10 mV / ±20 mV / ±30 mV / ±50 mV
Number of inputs 1
Sensor Strain gauge resistance Resistance measurement Total resistance of all parallel resistance measuring bridges: min. 87 Ω
Sensor supply 120 mA @ 10 V (= 4 x 350 Ω bridge resistors)
Load impedance current ≤ 600 Ω
load impedance voltage 600 Ω
Output current 0…22 mA (adjustable)
Output voltage, note 0…11 V (adjustable)
Type active connected control must be passive
Max. switching voltage, AC 0 V
Rated switching current 0.1 A
Accuracy <0.05 % of measuring range
Configuration DIP switch and button
Linearity Typically ± 0.05 % of signal range
Long-term drift 0.1 % / 10.000 h
Nominal power consumption 2 VA
Operating altitude ≤ 2000 m
Power consumption 3 W @ 24 V DC
Protection degree IP20
Rail TS 35
Step response time <400 ms (10…90 %)
Temperature coefficient typ. 0.005 % / °C
Voltage supply 10…60 V DC
EMC standards EN 61326
Insulation voltage 5.7 kV (input / output, input / supply)
Pollution severity 2
Rated voltage 300 V
Surge voltage category III
Type of connection PUSH IN
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.6 Nm
Clamping range, rated connection 2.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²
Wire connection cross section AWG, min. AWG 26
Wire connection cross section AWG, max. AWG 14
Wire cross-section, solid, min. 0.2 mm²
Wire cross-section, solid, max. 2.5 mm²
Wire connection cross section, finely stranded, min. 0.2 mm²
Wire connection cross section, finely stranded, max. 2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 2.5 mm²
Product information The ACT20P-BRIDGE-P bridge measuring transducer converts measuring bridge voltages into standard signals. Buttons are used for adjustment to the measuring bridge connected. The bridge measuring transducer can supply up to 4 parallel-connected measuring bridges each with 350 Ω. The device supports simple compensation of the tare weight with a separate input for an external button or an external PLC signal. The power supply is galvanically isolated from input and output (3-way isolation).T Features 4-wire and 6-wire measurement Supply of up to 4 parallel-connected measuring bridges each with 350 Ω Input and output ranges can be adjusted via DIP switches Tare compensation via external button or PLC signal Front LED indicates operation status 3-way galvanic isolation between input, output and power supply