Measuring bridge converter, Input : Resistance measuring bridge, Output : 0(4)-20 mA, 0-10 V
Technical Specifications:
| Depth | 113.6 mm |
| Depth (inches) | 4.472 inch |
| Height | 119.2 mm |
| Height (inches) | 4.693 inch |
| Width | 22.5 mm |
| Width (inches) | 0.886 inch |
| Net weight | 129.16 g |
| Storage temperature | -40 °C…85 °C |
| Operating temperature | -40 °C…70 °C |
| Humidity | 10…90 %, no condensation |
| SIL in compliance with IEC 61508 | None |
| MTTF | 543 a |
| RoHS Compliance Status | Compliant with exemption |
| RoHS Exemption (if applicable/known) | 7a, 7cI |
| REACH SVHC | Lead 7439-92-1 |
| SCIP | 2f6dd957-421a-46db-a0c2-cf1609156924 |
| Bridge sensitivity | 1.0 mV / V to 5.0 mV / V |
| Bridge supply voltage | 5 V or 10 V |
| Input signal | ±10 mV / ±20 mV / ±30 mV / ±50 mV |
| Number of inputs | 1 |
| Sensor | Strain gauge resistance Resistance measurement Total resistance of all parallel resistance measuring bridges: min. 87 Ω |
| Sensor supply | 120 mA @ 10 V (= 4 x 350 Ω bridge resistors) |
| Load impedance current | ≤ 600 Ω |
| load impedance voltage | 600 Ω |
| Output current | 0…22 mA (adjustable) |
| Output voltage, note | 0…11 V (adjustable) |
| Type | active connected control must be passive |
| Max. switching voltage, AC | 0 V |
| Rated switching current | 0.1 A |
| Accuracy | <0.05 % of measuring range |
| Configuration | DIP switch and button |
| Linearity | Typically ± 0.05 % of signal range |
| Long-term drift | 0.1 % / 10.000 h |
| Nominal power consumption | 4 VA |
| Operating altitude | ≤ 2000 m |
| Power consumption | 3 W @ 24 V DC |
| Protection degree | IP20 |
| Rail | TS 35 |
| Step response time | <400 ms (10…90 %) |
| Temperature coefficient | typ. 0.005 % / °C |
| Voltage supply | 10…60 V DC |
| EMC standards | EN 61326 |
| Insulation voltage | 5.7 kV (input / output, input / supply) |
| Pollution severity | 2 |
| Rated voltage | 300 V |
| Surge voltage category | III |
| Type of connection | Screw connection |
| Tightening torque, min. | 0.4 Nm |
| Tightening torque, max. | 0.6 Nm |
| Clamping range, rated connection | 2.5 mm² |
| Clamping range, min. | 0.5 mm² |
| Clamping range, max. | 2.5 mm² |
| Wire connection cross section AWG, min. | AWG 26 |
| Wire connection cross section AWG, max. | AWG 12 |
| Product information | The ACT20P-BRIDGE-S bridge measuring transducer converts measuring bridge voltages into standard signals. Buttons are used for adjustment to the measuring bridge connected. The bridge measuring transducer can supply up to 4 parallel-connected measuring bridges each with 350 Ω. The device supports simple compensation of the tare weight with a separate input for an external button or an external PLC signal. The power supply is electrogalvanised and isolated from the input and output (3-way isolation). Properties 4-wire and 6-wire measurement Supply of up to 4 parallel-connected measuring bridges each with 350 Ω Input and output ranges can be adjusted via DIP switches Tara compensation via external button or PLC signal Operating status display on a front panel LED Galvanic 3-way isolation between input, output and supply. |
| Long specification | Bridge measuring transformer with electrical 3-way isolation, configurablemeasurement isolating transformer in 22.5 mm width with external power supply, for recording,transforming and isolating of measurements from industrial strain gauges.Standard DC current/voltage signals are available on the output side. Measuring bridges of up to3 x 350 Ohm can be supplied via the input circuit. Automatic tare calibrationvia external switch signal, or manually with a press of a button.6-wire connection compensates for differences in wire resistance. Bridge excitation voltagecan be switched between 5 v and 10 V. Load cells can be calibrated using a button on the front side.I/O signals can be configured via DIP switches.Add-on housing for TS35 rail mountingDimensions: L/W/H 119.2/ 22.5/ 113.6 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20 Input Resistance measuring bridge / 1 mV / V… 5 mV / VBridge sensitivity +/- 10 mV / +/- 20 mV / +/- 30 mV / +/- 50 mV (adjustable)Input resistance > 1 MOhmBridge supply 5 V or 10 V Output 0…11 V / 0…22 mA configurable Load resistance 1 kOhm/ voltageTemperature coefficient typ. 50 ppm / KTransmission error typ. 0.05 % of inputStep response time < 400 ms (10…90 %)Auxiliary power 10…60 VDC Ambient temperature range -40°C…+70 °CIsolation EN 50178, 3-way isolation up to 5.7 kV of all circuits against each otherTest voltage 4 kV input against output against auxiliary powerRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULusType ACT20P-BRIDGE-S |
| Short specification | Bridge measuring transformer with electrical 3-way isolation, configurablemeasurement isolating transformer in 22.5 mm width with external power supply, for recording, transforming and isolating of measurements from industrial strain gauges. Standard DC current/voltages signals are available on the output side. Measuring bridges of up to 3 x 350 Ohm can be supplied via the input circuit. Automatic tare calibration via external switch signal, or manually with a press of a button. 6-wire connection compensates for differences in wire resistance. Bridge excitation voltage can be switched between 5 v and 10 V. Load cells can be calibrated using a button on the front side. I/O signals can be configured via DIP switches. |