Passive isolator, Input : 4-20 mA, Output : 2 x 4-20 mA, (loop powered), Signal distributor, Output current loop powered
Technical Specifications:
| Depth | 114 mm |
| Depth (inches) | 4.488 inch |
| Height | 127.1 mm |
| Height (inches) | 5.004 inch |
| Width | 12.5 mm |
| Width (inches) | 0.492 inch |
| Net weight | 140 g |
| Storage temperature | -40 °C…85 °C |
| Operating temperature | -20 °C…60 °C |
| Humidity at operating temperature | 0…95 % (no condensation) |
| Humidity | 5…95 %, no condensation |
| SIL in compliance with IEC 61508 | None |
| RoHS Compliance Status | Compliant with exemption |
| RoHS Exemption (if applicable/known) | 7a, 7cI |
| REACH SVHC | Lead 7439-92-1 |
| SCIP | 2f6dd957-421a-46db-a0c2-cf1609156924 |
| Input current | 4…20mA |
| Number of inputs | 1 |
| Sensor | 4- wire sensor (with own power supply) Current source |
| Voltage drop, current input | <3 V |
| Load impedance current | RL = (UB-12 V) / 20 ± 20mA, e.g. 600 Ω at 24 V |
| Output current | 4…20 mA, loop-powered |
| Type | passive connected control must be active |
| Max. switching voltage, AC | 0 V |
| Max. switching voltage, DC | 0 V |
| Rated switching current | 0.1 A |
| Accuracy | <0.1 % of end value |
| Configuration | none |
| Nominal power consumption | 2 VA |
| Operating altitude | ≤ 2000 m |
| Protection degree | IP20 |
| Rail | TS 35 |
| Step response time | ≤ 2 ms |
| Type of signal forwarding according to HART® | unchanged |
| Voltage supply | via output current loop min. 12 V DC/ max. 30 V DC |
| EMC standards | EN 61326-1 EN 61000-6-2 EN 61000-6-4 |
| Impulse withstand voltage | 4 kV (1.2/50 µs) |
| Insulation voltage | 2 kV (Input /Output), 1 min, 50 Hz |
| Rated voltage | 300 V |
| Surge voltage category | III |
| Marking | II 3 G Ex ec IIC T6 Gc |
| Type of connection | PUSH IN |
| Tightening torque, min. | 0.4 Nm |
| Tightening torque, max. | 0.6 Nm |
| Clamping range, rated connection | 2.5 mm² |
| Clamping range, min. | 0.5 mm² |
| Clamping range, max. | 2.5 mm² |
| Wire connection cross section AWG, min. | AWG 26 |
| Wire connection cross section AWG, max. | AWG 14 |
| Wire cross-section, solid, min. | 0.5 mm² |
| Wire cross-section, solid, max. | 2.5 mm² |
| Wire connection cross section, finely stranded, min. | 0.5 mm² |
| Wire connection cross section, finely stranded, max. | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. | 0.2 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. | 2.5 mm² |
| Product information | The ACT20P-CI-2CO-OLP-S fixed passive isolator isolates analogue standard current source signals. An analogue input current signal is converted linearly and doubled to provide two galvanically separated output current signals. The device is powered via the output current loop. Features 3-way galvanic isolation between input, output 1 and output 2. |