Passive isolator, Input : 0-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Technical Specifications:
| Depth | 114 mm |
| Depth (inches) | 4.488 inch |
| Height | 117.2 mm |
| Height (inches) | 4.614 inch |
| Width | 12.5 mm |
| Width (inches) | 0.492 inch |
| Net weight | 100 g |
| Storage temperature | -40 °C…85 °C |
| Operating temperature | -20 °C…60 °C |
| Humidity at operating temperature | 0…95 % (no condensation) |
| Humidity | 5…95 %, no condensation |
| SIL in compliance with IEC 61508 | None |
| RoHS Compliance Status | Compliant with exemption |
| RoHS Exemption (if applicable/known) | 7a, 7cI |
| REACH SVHC | Lead 7439-92-1 |
| SCIP | 2f6dd957-421a-46db-a0c2-cf1609156924 |
| Input current | 0…20 mA |
| Number of inputs | 1 |
| Sensor | Current source 4- wire sensor (with own power supply) |
| Voltage drop, current input | <3 V |
| Load impedance current | ≤ 600 Ω |
| Number of outputs | 1 |
| Output current | 4…20 mA, loop-powered |
| Type | passive connected control must be active |
| Max. switching voltage, AC | 0 V |
| Max. switching voltage, DC | 0 V |
| Rated switching current | 0.1 A |
| Accuracy | <0.1 % of end value |
| Configuration | none |
| Nominal power consumption | 2 VA |
| Operating altitude | ≤ 2000 m |
| Protection degree | IP20 |
| Rail | TS 35 |
| Step response time | ≤ 1 ms |
| Temperature coefficient | ≤ 100 ppm/K |
| Voltage supply | via output current loop min. 12 V DC/ max. 30 V DC |
| EMC standards | EN 61326-1 EN 61000-6-2 EN 61000-6-4 |
| Galvanic isolation | 2-way isolator |
| Impulse withstand voltage | 4 kV (1.2/50 µs) |
| Insulation voltage | 2 kV inputs / outputs |
| Pollution severity | 2 |
| Rated voltage | 300 V |
| Surge voltage category | III |
| Marking | II 3 G Ex ec IIC T6 Gc |
| Type of connection | Screw connection |
| Tightening torque, min. | 0.4 Nm |
| Tightening torque, max. | 0.6 Nm |
| Clamping range, rated connection | 2.5 mm² |
| Clamping range, min. | 0.5 mm² |
| Clamping range, max. | 2.5 mm² |
| Wire connection cross section AWG, min. | AWG 26 |
| Wire connection cross section AWG, max. | AWG 12 |
| Product information | The ACT20P-CIX-CO-OLP-S single-channel fixed passive isolator isolates analogue standard current source signals. An analogue input current signal is converted linear and galvanic isolated into an analogue output current signal. The device is powered via the output current loop. Features 2-way galvanic isolation between input and output. |