Analogue isolating amplifier, 24 V DC power supply, Input : I/U universal, Output : I/U universal
Technical Specifications:
| Depth | 113.7 mm |
| Depth (inches) | 4.476 inch |
| Height | 119.2 mm |
| Height (inches) | 4.693 inch |
| Width | 12.5 mm |
| Width (inches) | 0.492 inch |
| Net weight | 130 g |
| Operating temperature | -20 °C…60 °C |
| Humidity at operating temperature | 0…95 % (no condensation) |
| SIL in compliance with IEC 61508 | None |
| MTBF | 76 a |
| RoHS Compliance Status | Compliant with exemption |
| RoHS Exemption (if applicable/known) | 7a, 7cI |
| REACH SVHC | Lead 7439-92-1 |
| SCIP | 2f6dd957-421a-46db-a0c2-cf1609156924 |
| Input current | configurable ± 0.1mA…± 100 mA Measuring range min. 200 µA |
| Input resistance, current | 5 mA: approx. 5 Ω |
| Input resistance, voltage | ≥ 1 MΩ |
| Input signal | Current or voltage input is selectable |
| Input voltage | configurable ±40 mV…±300 V Measuring range. min 40 mV (Example: 0…+40 mV or -40…0 mV or -20….+20 mV or….) Measuring range, max: 300 V |
| Number of inputs | 1 |
| Sensor | 4- wire sensor (with own power supply) |
| Cut-off frequency (-3 dB) | > 10 kHz/ <10 Hz |
| Load impedance current | ≤ 600 Ω |
| load impedance voltage | ≥ 1 kΩ |
| Offset current | 20 µA |
| Offset voltage | <10 mV |
| Output current | configurable 0…±20 mA |
| Output voltage, note | configurable 0…±10 V |
| Type | active (as current source) or passive (as current sink) connected control can be active / passive |
| Display value | current measured value Configuration data |
| Type | Dot-matrix display with ticker text, green |
| Accuracy | <0.05 % of measuring range |
| Configuration | DIP switch or via display and push-buttons |
| Nominal power consumption | 2 VA |
| Operating altitude | ≤ 2000 m |
| Power consumption | ≤2.3 W |
| Protection degree | IP20 |
| Rail | TS 35 |
| Step response time | ≤50 µs |
| Temperature coefficient | ≤0,01% des Messbereichs⁄°C |
| Voltage supply | 24 V DC (-20% / +30%) |
| EMC standards | EN 61326-1 |
| Galvanic isolation | 3-way isolator between input ⁄ output ⁄ supply |
| Impulse withstand voltage | 5 kV (1.2/50 µs) |
| Insulation voltage | 4 kVeff input / output / power supply |
| Pollution severity | 2 |
| Rated voltage | 600 V |
| Surge voltage category | II |
| Marking | II 3 G Ex nA IIC T4 Gc |
| Type of connection | Screw connection |
| Tightening torque, min. | 0.4 Nm |
| Tightening torque, max. | 0.6 Nm |
| Clamping range, rated connection | 2.5 mm² |
| Clamping range, min. | 0.5 mm² |
| Clamping range, max. | 2.5 mm² |
| Wire connection cross section AWG, min. | AWG 26 |
| Wire connection cross section AWG, max. | AWG 12 |
| Product information | The universally configurable DC isolating amplifier ACT20P-PRO DCDC II isolates and converts analogue signals. An analogue input signal (current or voltage) is linearly converted into an analogue output signal (current or voltage) and galvanically isolated. The power supply is galvanically isolated from the input and output (3-way isolation). Properties universal wide-range voltage supply universally configurable via DIP switch or via the LED display using control buttons Active or passive signal output Operating status display on a front panel LED Galvanic 3-way isolation between input, output and supply. |





Reviews
There are no reviews yet.