Frequency signal converter, Limit value monitoring, Frequency, PWM, analogue V / mA, Transistor (Alarm)
Technical Specifications:
| Depth | 113.7 mm |
| Depth (inches) | 4.476 inch |
| Height | 117.2 mm |
| Height (inches) | 4.614 inch |
| Width | 12.5 mm |
| Width (inches) | 0.492 inch |
| Net weight | 999 g |
| Storage temperature | -40 °C…85 °C |
| Operating temperature | -40 °C…60 °C |
| Humidity | 0…95 % (no condensation) |
| SIL in compliance with IEC 61508 | None |
| RoHS Compliance Status | Compliant with exemption |
| RoHS Exemption (if applicable/known) | 7a, 7cI |
| REACH SVHC | Lead 7439-92-1 |
| SCIP | 2f6dd957-421a-46db-a0c2-cf1609156924 |
| Frequency range, max. | 200,000 Hz |
| Frequency range, min. | 0 Hz |
| Input frequency | 0,01 Hz…200 kHz |
| Input voltage | Threshold voltage (NPN / PNP Sensor): 3 V…43.5 V (configurable) Hysterisis level: ≥0.5 V |
| Number of inputs | 1 |
| Sensor | NPN / PNP transistor (trig-level low: ≤4 V high: ≥7 V ) NAMUR sensor, according to EN60947-5-6 switch with or without RS, RP 2-wire transmitter (without own power supply) 3 wire NPN/PNP-transistor frequency generator PDM |
| Sensor supply | 18 V ±15 % 8.2 V ±15% (@ NAMUR sensor) |
| Pulse duty factor | 0–-100% push/pull or push, parameterisable |
| PWM measurement, gate time | 20 ms … 20 s |
| PWM measurement, step response time | 20 ms … 20 s + 20 ms |
| Alarm function | configurable Top and bottom limit values, window range Short circuit at input Alarm delay: 0…10 s Hysteresis adjustable |
| Hysteresis | 1…20 % |
| Number of digital outputs | 1 |
| Rated switching current | 100 mA |
| Rated switching voltage | 24 VDC ±30% |
| Switch-on delay | 0…180 s |
| Type | NPN-Transitor Switching frequency 5 kHz |
| Load resistance current | ≤ 600 Ω |
| Load resistance voltage | ≥ 1 kΩ |
| Number of analogue outputs | 1 |
| Output current | -20…+20 mA ± 10mA 0(4)…20 mA configurable downscale (3.5 mA) ⁄ upscale (23 mA) @ error |
| Output voltage | 0…5 V 0(1)…5 V 0(2)…10 V -5…+5 V -10…+10 V |
| Signal output | direct or inverted |
| Transmit function | linear, √X, X1, X1.5, X2, X2.5, 1-X direct or inverted -5…+5 % of output span (TRIM) |
| Type (analogue output) | Voltage and current output (configurable) |
| Accuracy | ≤0.05 % of span |
| Configuration | with push-buttons and display |
| Long-term drift | ≤±0.05% of the measurement range / year |
| Nominal power consumption | 1 VA |
| Operating altitude | ≤ 2000 m |
| Power consumption | ≤ 2.6 W |
| Protection degree | IP20 |
| Rail | TS 35 |
| Step response time | 40 ms + period |
| Temperature coefficient | ≤ 0.02 % / °C ≤ 100 ppm/K of final value |
| Voltage supply | 24…230 V DC ±15% 24…230 V AC ±15% @48…62 Hz |
| EMC standards | EN 61326-1 |
| Galvanic isolation | 4-way isolator; |
| Impulse withstand voltage | 5 kV (1.2/50 µs) |
| Insulation voltage | 4 kVeff / 1 min. |
| Pollution severity | 2 |
| Rated voltage | 600 V |
| Surge voltage category | II |
| Safety category | No |
| Type of connection | Screw connection |
| Stripping length, rated connection | 8 mm |
| Tightening torque, min. | 0.4 Nm |
| Tightening torque, max. | 0.6 Nm |
| Wire connection cross section, finely stranded, min. | 0.2 mm² |
| Wire connection cross section, finely stranded, max. | 2 mm² |
| Wire cross-section, finely stranded, min. (AWG) | AWG 24 |
| Wire cross-section, finely stranded, max. (AWG) | AWG 14 |