PCB plug-in connector, female plug, 3.50 mm, Number of poles: 4, 180°, PUSH IN with actuator, Clamping range, max. : 1.5 mm², Box

Technical Specifications:

Depth 29.9 mm
Depth (inches) 1.177 inch
Height 17.25 mm
Height (inches) 0.679 inch
Width 13.9 mm
Width (inches) 0.547 inch
Net weight 3.376 g
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Product Carbon Footprint Cradle to gate: 0.044 kg CO2eq.
Product family OMNIMATE Signal – series B2C/S2C 3.50 – 2-row
Type of connection Field connection
Wire connection method PUSH IN with actuator
Pitch in mm (P) 3.5 mm
Pitch in inches (P) 0.138 “
Conductor outlet direction 180°
Number of poles 4
L1 in mm 3.5 mm
L1 in inches 0.138 “
Number of rows 1
Pin series quantity 2
Rated cross-section 15 mm²
Touch-safe protection acc. to DIN VDE 57 106 Safe from finger touch
Touch-safe protection acc. to DIN VDE 0470 IP20 plugged
Protection degree IP20 when fully mounted
Can be coded Yes
Stripping length 10 mm
Screwdriver blade 0.4 x 2.5
Screwdriver blade standard DIN 5264
Plugging cycles 25
Plugging force/pole, max. 5 N
Pulling force/pole, max. 5 N
Insulating material PA 66 GF 30
Colour black
Colour chart (similar) RAL 9011
Insulating material group II
Comparative Tracking Index (CTI) ≥ 600
Insulation strength ≥ 108 Ω
UL 94 flammability rating V-0
Contact material Copper alloy
Contact surface tinned
Layer structure of plug contact 2…5 µm Sn hot-dip tinned
Storage temperature, min. -40 °C
Storage temperature, max. 70 °C
Operating temperature, min. -50 °C
Operating temperature, max. 120 °C
Temperature range, installation, min. -40 °C
Temperature range, installation, max. 120 °C
Clamping range, min. 0.14 mm²
Clamping range, max. 1.5 mm²
Wire connection cross section AWG, min. AWG 30
Wire connection cross section AWG, max. AWG 16
Solid, min. H05(07) V-U 0.14 mm²
Solid, max. H05(07) V-U 1.5 mm²
Flexible, min. H05(07) V-K 0.14 mm²
Flexible, max. H05(07) V-K 1.5 mm²
w. plastic collar ferrule, DIN 46228 pt 4, min. 0.14 mm²
w. plastic collar ferrule, DIN 46228 pt 4, max. 1 mm²
w. wire end ferrule, DIN 46228 pt 1, min. 0.14 mm²
w. wire end ferrule, DIN 46228 pt 1, max. 1.5 mm²
Clampable conductor Cross-section for conductor connection: nominal: 0.14 mm² wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9028240000 Cross-section for conductor connection: nominal: 0.25 mm² wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9025780000 Cross-section for conductor connection: nominal: 0.34 mm² wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9025790000 Cross-section for conductor connection: nominal: 0.5 mm² wire end ferrule: Stripping length: nominal: 12 mm Recommended wire-end ferrule: 9028270000 Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9004050000 Cross-section for conductor connection: nominal: 0.75 mm² wire end ferrule: Stripping length: nominal: 12 mm Recommended wire-end ferrule: 9028290000 Stripping length: nominal: 10 mm Recommended wire-end ferrule: 0542500000 Cross-section for conductor connection: nominal: 1 wire end ferrule: Stripping length: nominal: 12 mm Recommended wire-end ferrule: 9028320000 Stripping length: nominal: 10 mm Recommended wire-end ferrule: 0282800000 Cross-section for conductor connection: nominal: 1.5 mm² wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 0186500000
Reference text The outside diameter of the plastic collar should not be larger than the pitch (P) Length of ferrules is to be chosen depending on the product and the rated voltage.
tested acc. to standard IEC 60664-1 IEC 61984
Rated current, min. number of poles (Tu=20°C) 13.4 A
Rated current, max. number of poles (Tu=20°C) 10 A
Rated current, min. number of poles (Tu=40°C) 12 A
Rated current, max. number of poles (Tu=40°C) 9 A
Rated voltage for surge voltage class / pollution degree II/2 320 V
Rated voltage for surge voltage class / pollution degree III/2 160 V
Rated voltage for surge voltage class / pollution degree III/3 160 V
Rated impulse voltage for surge voltage class/ pollution degree II/2 2.5 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2 2.5 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3 2.5 kV
Short-time withstand current resistance 3 x 1s with 80 A
Institute (CSA) CSA
Certificate No. (CSA) 200039-1121690
Rated voltage (Use group B / CSA) 300 V
Rated voltage (Use group C / CSA) 50 V
Rated voltage (Use group D / CSA) 300 V
Rated current (Use group B / CSA) 9.5 A
Rated current (Use group C / CSA) 9.5 A
Rated current (Use group D / CSA) 9.5 A
Wire cross-section, AWG, min. AWG 30
Wire cross-section, AWG, max. AWG 16
Reference to approval values Specifications are maximum values, details – see approval certificate.
Institute (cURus) CURUS
Certificate No. (cURus) E60693
Rated voltage (Use group B / UL 1059) 300 V
Rated voltage (Use group C / UL 1059) 50 V
Rated voltage (Use group D / UL 1059) 300 V
Rated current (Use group B / UL 1059) 9.5 A
Rated current (Use group C / UL 1059) 9.5 A
Rated current (Use group D / UL 1059) 9.5 A
Wire cross-section, AWG, min. AWG 30
Wire cross-section, AWG, max. AWG 16
Reference to approval values Specifications are maximum values, details – see approval certificate.
Packaging Box
VPE length 350 mm
VPE width 135 mm
VPE height 40 mm
Test Durability of markings Standard: IEC 61984 section 6.2 and 7.3.2 / 10.11 taking pattern from IEC 60068-2-70 / 12.95 Test: mark of origin, type identification, pitch, type of material, date clock, approval marking UL, approval marking cULus Evaluation: available Test: durability Evaluation: passed
Test Misengagement (Non-interchangeability) Standard: IEC 61984 section 6.3 and 6.9.1 / 10.11, IEC 60512-13-5 / 02.06 Test: 180° turned without coding elements Evaluation: passed Test: 180° turned with coding elements Evaluation: passed Test: visual examination Evaluation: passed
Test Clampable cross section Standard: IEC 60999-1 section 7 and 9.1 / 11.99, IEC 60947-1 section 8.2.4.5.1 / 03.11 Conductor type: Type of conductor and conductor cross-section: solid 0.14 mm² Type of conductor and conductor cross-section: stranded 0.14 mm² Type of conductor and conductor cross-section: solid 1.5 mm² Type of conductor and conductor cross-section: stranded 1.5 mm² Type of conductor and conductor cross-section: AWG 26/1 Type of conductor and conductor cross-section: AWG 26/19 Type of conductor and conductor cross-section: AWG 16/1 Type of conductor and conductor cross-section: AWG 16/19 Evaluation: passed
Test for damage to and accidental loosening of conductors Standard: IEC 60999-1 section 9.4 / 11.99 Requirement: 0.2 kg Conductor type: Type of conductor and conductor cross-section: AWG 26/1 Type of conductor and conductor cross-section: AWG 26/19 Evaluation: passed Requirement: 0.3 kg Conductor type: Type of conductor and conductor cross-section: H05V-U0.75 Type of conductor and conductor cross-section: H05V-K0.75 Evaluation: passed Requirement: 0.4 kg Conductor type: Type of conductor and conductor cross-section: H07V-U1.5 Type of conductor and conductor cross-section: H07V-K1.5 Type of conductor and conductor cross-section: AWG 16/1 Type of conductor and conductor cross-section: AWG 16/19 Evaluation: passed
Pull-out test Standard: IEC 60999-1 section 9.5 / 11.99 Requirement: ≥10 N Conductor type: Type of conductor and conductor cross-section: AWG 26/1 Type of conductor and conductor cross-section: AWG 26/19 Evaluation: passed Requirement: ≥20 N Conductor type: Type of conductor and conductor cross-section: H05V-U0.75 Type of conductor and conductor cross-section: H05V-K0.75 Evaluation: passed Requirement: ≥40 N Conductor type: Type of conductor and conductor cross-section: H07V-U1.5 Type of conductor and conductor cross-section: H07V-K1.5 Type of conductor and conductor cross-section: AWG 16/1 Type of conductor and conductor cross-section: AWG 16/19 Evaluation: passed
IPC conformity Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 “Class 2”. Further claims on the products can be evaluated on request.
Notes Additional variants on request Gold-plated contact surfaces on request Rated current related to rated cross-section & min. No. of poles. Crimp shape A for wire-end ferrules with crimping tools PZ 1,5 (order no. 9005990000) or PZ 6/5 (order no. 9011460000) for larger wire cross-sections recommended. P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. Max. outer diameter of the conductor 2.6 mm In accordance with IEC 61984, OMNIMATE-connectors are connectors without breaking capacity (COC). During designated use, connectors are not allowed to be engaged or disengaged when live or under load Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months