Weidmueller BL 3.50/08/270F SN OR BX

Request a price

BL 3.50/08/270F SN OR BX

SKU: 1639990000.0 Category: Brand:

PCB plug-in connector, female plug, 3.50 mm, Number of poles: 8, 270°, Clamping yoke connection, Clamping range, max. : 1.5 mm², Box

Technical Specifications:

Depth 22.45 mm
Depth (inches) 0.884 inch
Height 12 mm
Height (inches) 0.472 inch
Width 35 mm
Width (inches) 1.378 inch
Net weight 8 g
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Product family OMNIMATE Signal – series BL/SL 3.50
Type of connection Field connection
Wire connection method Clamping yoke connection
Pitch in mm (P) 3.5 mm
Pitch in inches (P) 0.138 “
Conductor outlet direction 270°
Number of poles 8
L1 in mm 24.5 mm
L1 in inches 0.965 “
Number of rows 1
Pin series quantity 1
Rated cross-section 1.5 mm²
Touch-safe protection acc. to DIN VDE 57 106 Safe from finger touch
Touch-safe protection acc. to DIN VDE 0470 IP20 plugged/ IP10 unplugged
Protection degree IP20 when fully mounted
Volume resistance ≤5 mΩ
Can be coded Yes
Stripping length 6 mm
Clamping screw M 2
Screwdriver blade 0.4 x 2.5
Screwdriver blade standard DIN 5264
Plugging cycles 25
Plugging force/pole, max. 7 N
Pulling force/pole, max. 5 N
Tightening torque Torque type: Wire connection Usage information: Tightening torque: min.: 0.2 Nm max.: 0.25 Nm Torque type: Screw flange Usage information: Tightening torque: min.: 0.15 Nm max.: 0.2 Nm
Insulating material PBT
Colour orange
Colour chart (similar) RAL 2000
Insulating material group IIIa
Comparative Tracking Index (CTI) ≥ 200
Insulation strength ≥ 108 Ω
UL 94 flammability rating V-0
Contact material Cu-alloy
Contact surface tinned
Layer structure of plug contact 4…8 µm Sn hot-dip tinned
Storage temperature, min. -40 °C
Storage temperature, max. 70 °C
Operating temperature, min. -50 °C
Operating temperature, max. 100 °C
Temperature range, installation, min. -30 °C
Temperature range, installation, max. 100 °C
Clamping range, min. 0.08 mm²
Clamping range, max. 1.5 mm²
Wire connection cross section AWG, min. AWG 28
Wire connection cross section AWG, max. AWG 14
Solid, min. H05(07) V-U 0.2 mm²
Solid, max. H05(07) V-U 1.5 mm²
Flexible, min. H05(07) V-K 0.2 mm²
Flexible, max. H05(07) V-K 1.5 mm²
w. plastic collar ferrule, DIN 46228 pt 4, min. 0.2 mm²
w. plastic collar ferrule, DIN 46228 pt 4, max. 1.5 mm²
w. wire end ferrule, DIN 46228 pt 1, min. 0.2 mm²
w. wire end ferrule, DIN 46228 pt 1, max. 1.5 mm²
Plug gauge in accordance with EN 60999 a x b; ø 2.4 mm x 1.5 mm
Clampable conductor Cross-section for conductor connection: Type: fine-wired nominal: 0.5 mm² wire end ferrule: Stripping length: nominal: 8 mm Recommended wire-end ferrule: 0409500000 Stripping length: nominal: 6 mm Recommended wire-end ferrule: 0282600000 Cross-section for conductor connection: Type: fine-wired nominal: 0.75 mm² wire end ferrule: Stripping length: nominal: 8 mm Recommended wire-end ferrule: 0409600000 Stripping length: nominal: 6 mm Recommended wire-end ferrule: 0282700000 Cross-section for conductor connection: Type: fine-wired nominal: 1 mm² wire end ferrule: Stripping length: nominal: 8 mm Recommended wire-end ferrule: 0409700000 Stripping length: nominal: 6 mm Recommended wire-end ferrule: 0372600000 Cross-section for conductor connection: Type: fine-wired nominal: 0.25 mm² wire end ferrule: Stripping length: nominal: 8 mm Recommended wire-end ferrule: 9025740000 Stripping length: nominal: 5 mm Recommended wire-end ferrule: 9018910000 Cross-section for conductor connection: Type: fine-wired nominal: 0.34 mm² wire end ferrule: Stripping length: nominal: 8 mm Recommended wire-end ferrule: 9025750000
Reference text The outside diameter of the plastic collar should not be larger than the pitch (P) Length of ferrules is to be chosen depending on the product and the rated voltage.
tested acc. to standard IEC 60664-1 IEC 61984
Rated current, min. number of poles (Tu=20°C) 12 A
Rated current, max. number of poles (Tu=20°C) 10 A
Rated current, min. number of poles (Tu=40°C) 10 A
Rated current, max. number of poles (Tu=40°C) 8 A
Rated voltage for surge voltage class / pollution degree II/2 320 V
Rated voltage for surge voltage class / pollution degree III/2 160 V
Rated voltage for surge voltage class / pollution degree III/3 160 V
Rated impulse voltage for surge voltage class/ pollution degree II/2 2.5 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2 2.5 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3 2.5 kV
Short-time withstand current resistance 3 x 1s with 100 A
Institute (CSA) CSA
Certificate No. (CSA) 154685-1318353
Rated voltage (Use group B / CSA) 300 V
Rated voltage (Use group D / CSA) 300 V
Rated current (Use group B / CSA) 10 A
Rated current (Use group D / CSA) 10 A
Wire cross-section, AWG, min. AWG 28
Wire cross-section, AWG, max. AWG 14
Reference to approval values Specifications are maximum values, details – see approval certificate.
Institute (UR) UR
Certificate No. (UR) E60693
Rated voltage (Use group B / UL 1059) 300 V
Rated voltage (Use group D / UL 1059) 300 V
Rated current (Use group B / UL 1059) 8 A
Rated current (Use group D / UL 1059) 8 A
Wire cross-section, AWG, min. AWG 28
Wire cross-section, AWG, max. AWG 14
Reference to approval values Specifications are maximum values, details – see approval certificate.
Packaging Box
VPE length 349 mm
VPE width 142 mm
VPE height 31 mm
Test Durability of markings Standard: DIN EN 61984 section 7.3.2 / 09.02 taking pattern from DIN EN 60068-2-70 / 07.96 Test: mark of origin, type identification, approval marking SEV, approval marking CSA Evaluation: available Test: durability Evaluation: passed
Test Misengagement (Non-interchangeability) Standard: DIN EN 61984 section 6.3 and 6.9.1 / 09.02, DIN IEC 60512 part 7 section 5 / 05.94 Test: 180° turned with coding elements Evaluation: passed
Test Clampable cross section Standard: DIN EN 60999-1 section 7 and 9.1 / 12.00, DIN EN 60947-1 section 8.2.4.5.1 / 12.99 Conductor type: Type of conductor and conductor cross-section: solid 0.2 mm² Type of conductor and conductor cross-section: stranded 0.2 mm² Type of conductor and conductor cross-section: solid 1.5 mm² Type of conductor and conductor cross-section: stranded 1.5 mm² Type of conductor and conductor cross-section: AWG 28/1 Type of conductor and conductor cross-section: AWG 28/19 Type of conductor and conductor cross-section: AWG 16/1 Type of conductor and conductor cross-section: AWG 16/19 Evaluation: passed
Test for damage to and accidental loosening of conductors Standard: DIN EN 60999-1 section 9.4 / 12.00 Requirement: 0.2 kg Conductor type: Type of conductor and conductor cross-section: AWG 28/1 Type of conductor and conductor cross-section: AWG 28/19 Evaluation: passed Requirement: 0.3 kg Conductor type: Type of conductor and conductor cross-section: 2 × AWG 24/1 Type of conductor and conductor cross-section: 2 × AWG 24/19 with wire end ferrule Evaluation: passed Requirement: 0.4 kg Conductor type: Type of conductor and conductor cross-section: solid 1.5 mm² Type of conductor and conductor cross-section: stranded 1.5 mm² Type of conductor and conductor cross-section: AWG 16/7 Evaluation: passed
Pull-out test Standard: DIN EN 60999-1 section 9.5 / 12.00 Requirement: ≥5 N Conductor type: Type of conductor and conductor cross-section: AWG 28/1 Type of conductor and conductor cross-section: AWG 28/19 Evaluation: passed Requirement: ≥10 N Conductor type: Type of conductor and conductor cross-section: 2 × AWG 24/1 Type of conductor and conductor cross-section: 2 × AWG 24/19 with wire end ferrule Evaluation: passed Requirement: ≥40 N Conductor type: Type of conductor and conductor cross-section: H05V-U1.5 Type of conductor and conductor cross-section: H05V-K1.5 Type of conductor and conductor cross-section: AWG 16/7 Evaluation: passed
IPC conformity Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 “Class 2”. Further claims on the products can be evaluated on request.
Notes Additional variants on request Gold-plated contact surfaces on request Max. outer diameter of the conductor: 2.9 mm Max. outer diameter of the conductor: 2.9 mm Wire end ferrule without plastic collar to DIN 46228/1 Wire end ferrule with plastic collar to DIN 46228/4 P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. In accordance with IEC 61984, OMNIMATE-connectors are connectors without breaking capacity (COC). During designated use, connectors are not allowed to be engaged or disengaged when live or under load Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months

Reviews