Weidmueller FP BOX ON/OFF W/O AUX

Request a price

FP BOX ON/OFF W/O AUX

SKU: 2921380000.0 Category: Brand:

FieldPower® power distribution box, 3-phase AC, IP65, in complete state, glass-fibre reinforced polycarbonate, Insulation displacement connection (IDC), PUSH IN, Maintenance switch

Technical Specifications:

Depth 164 mm
Depth (inches) 6.457 inch
Width 104 mm
Width (inches) 4.094 inch
Net weight 894 g
Storage temperature -40 °C…55 °C
Operating temperature -40 °C…45 °C
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 6c
REACH SVHC Lead 7439-92-1 Potassium perfluorobutane sulfonate 29420-49-3
SCIP 7645f3b1-6db9-495d-9e21-ab1d894aff05
Connection data – contact element power bus Wire connection method: Insulation displacement connection (IDC) Blade size of operating tool: 0.6 x 3.5 mm Number of poles: 5 Conductor connection cross-section, solid, max.: 6 mm² Conductor connection cross-section, solid, min.: 1.5 mm² Conductor connection cross-section, stranded, max.: 6 mm² Conductor connection cross-section, stranded, min.: 2.5 mm² Conductor connection cross-section, finely stranded, max.: 6 mm² Conductor connection cross-section, finely stranded, min.: 2.5 mm² Conductor connection cross-section, finest stranded, max.: 6 mm² Conductor connection cross-section, finest stranded, min.: 2.5 mm²
Connection data – contact element Branch / Feed-in Wire connection method: PUSH IN Blade size of operating tool: 0.6 x 3.5 mm Stripping length: 14 mm Number of poles: 5 Conductor connection cross-section, solid, max.: 6 mm² Conductor connection cross-section, solid, min.: 0.5 mm² Conductor connection cross-section, stranded, max.: 6 mm² Conductor connection cross-section, stranded, min.: 0.5 mm² Conductor connection cross-section, finely stranded, max.: 10 mm² Conductor connection cross-section, finely stranded, min.: 0.5 mm² Conductor connection cross-section, finest stranded, max.: 6 mm² Conductor connection cross-section, finest stranded, min.: 0.5 mm² Conductor connection cross-section with wire end ferrule: Type of wire end ferrule: 12 mm with plastic collar Standard: DIN 46228/1 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: 12 mm with plastic collar Standard: DIN 46228/4 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: 8 mm with plastic collar Standard: DIN 46228/1 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: 8 mm with plastic collar Standard: DIN 46228/4 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: Twin wire-end ferrules Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm²
Insulating material Polycarbonate
Enclosure material glass-fibre reinforced polycarbonate
Silicone No
Colour black
Protection degree IP65 in complete state
UL 94 flammability rating 5VA
Torque for lid screws 2 Nm
Lid attachment TX20 screws
lockable Yes
Type of mounting Screw mounting Fixing lugs
Installation advice Lid screws included
Function Maintenance switch
With cable gland No
Can be coded Yes Coded on PE
Voltage type 3-phase AC
Number of poles 5
Number of connections / pole 1
Wire connection method Insulation displacement connection (IDC) PUSH IN
Rated data acc. to IEC for contact element Voltage type: AC Number of phases: 3 Standard: IEC 60947-7-1, IEC 60947-7-2 Rated voltage: 800 V Rated impulse withstand voltage: 8 kV Rated current (3 loaded poles): 41 A Rated current (4 loaded poles): 25 A
Rated data acc. to IEC for plug-in connector Voltage type: AC Number of phases: 3 Standard: IEC 60947-7-1, IEC 60947-7-2, IEC 61984 Rated voltage: 690 V Rated impulse withstand voltage: 8 kV Rated current (3 loaded poles): 32 A Rated current (4 loaded poles): 25 A
Rated data acc. to UL for contact element Standard: UL 1059 Note: for use with UL-listed TC-ER cables Conductor connection cross-section, AWG, max.: AWG 10 Conductor connection cross-section, AWG, min.: AWG 14 Rated voltage: 600 V Rated current: 30 A
Rated data acc. to UL for plug-in connector Standard: UL 1059 Note: for use with UL-listed TC-ER cables Conductor connection cross-section, AWG, max.: AWG 12 Conductor connection cross-section, AWG, min.: AWG 16 Rated voltage: 600 V Rated current: 20 A
Standards not UL approved
Clamping range, plug, max. 10 mm²
Clamping range, plug, min. 0.75 mm²
Pollution severity 3
Power rating AC-23A 7.5 kW
Rated current AC-23A 16 A
Rated short-term current resistance ICW 500 A rms for 1 Second
Switch according to standard IEC 60947-3
Switch type ABB OT16FT3
Terminals – torque 0.8 Nm
Wire connection cross section AWG, max. AWG 8
Wire connection cross section AWG, min. AWG 18

Reviews

There are no reviews yet.

Be the first to review “Weidmueller FP BOX ON/OFF W/O AUX”

Your email address will not be published. Required fields are marked *