Weidmueller FP PRO TOP3 24/20 2PIOL

Request a price

FP PRO TOP3 24/20 2PIOL

SKU: 2743460000.0 Category: Brand:

FieldPower® power supply unit, IP65, in closed state, in complete state, 20A, 24 V, DC, IDC terminal, PUSH IN, M12 A-coded (IO-Link)

Technical Specifications:

Depth 220 mm
Depth (inches) 8.661 inch
Height 196 mm
Height (inches) 7.717 inch
Width 196 mm
Width (inches) 7.717 inch
Net weight 4,256 g
Storage temperature -10 °C…60 °C
Operating temperature -25 °C…45 °C
Operating temperature range -25…50 ℃
Start-up ≥ -40 °C
Humidity 35…85%, non condensing and non freezing
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 6c, 7a, 7cI
REACH SVHC Lead 7439-92-1 Potassium perfluorobutane sulfonate 29420-49-3
SCIP 7645f3b1-6db9-495d-9e21-ab1d894aff05
AC current consumption 1,5 A @ 400 V DC / 2 A @ 320 V AC
AC input voltage range 3 x 320…3 x 575 V AC / 2 x 360…2 x 575 V AC
DC input voltage range 450…800 V DC (max. 500 V DC acc. to UL508)
Frequency range AC 45…65 Hz
Input fuse (internal) 5 A F (6.3 x 32 mm)
Inrush current Max. 10 A
Recommended back-up fuse 3 – 5 A, Char C
Surge protection Varistor
Wire connection method IDC terminal PUSH IN
Adjustable rated current No
Nominal output current for Unom 20 A @ 60 °C
Output current 20A
Output power 480 W
Output voltage 24 V
Output voltage type DC
Output voltage, max. 28.8 V
Output voltage, min. 22.5 V
Output voltage, note (adjustable via potentiometer)
Rated output voltage 24 V DC ± 1 %
Surge protection Varistor
Switch-on delay 1 s
Triggering characteristic see characteristic curve
Wire connection method IDC terminal PUSH IN
Humidity 35…85%, non condensing and non freezing
Installation advice Lid screws included
Protection degree IP65 in closed state in complete state
Short-circuit protection Yes internal
Standards UL 508
Surge voltage category III II
Surge voltage category III II
AC current consumption 1,5 A @ 400 V DC / 2 A @ 320 V AC
AC input voltage range 3 x 320…3 x 575 V AC / 2 x 360…2 x 575 V AC
DC input voltage range 450…800 V DC (max. 500 V DC acc. to UL508)
Frequency range AC 45…65 Hz
Recommended back-up fuse 3 – 5 A, Char C
Surge protection Varistor
Inrush current Max. 10 A
Input fuse (internal) 5 A F (6.3 x 32 mm)
Adjustable rated current No
Output current 20A
Output power 480 W
Output voltage 24 V
Output voltage type DC
Output voltage, max. 28.8 V
Output voltage, min. 22.5 V
Output voltage, note (adjustable via potentiometer)
Switch-on delay 1 s
Triggering characteristic see characteristic curve
Rated output voltage 24 V DC ± 1 %
Nominal output current for Unom 20 A @ 60 °C
Connection data – contact element power bus Wire connection method: Insulation displacement connection (IDC) Blade size of operating tool: 0.6 x 3.5 mm Number of poles: 5 Conductor connection cross-section, solid, max.: 6 mm² Conductor connection cross-section, solid, min.: 1.5 mm² Conductor connection cross-section, stranded, max.: 6 mm² Conductor connection cross-section, stranded, min.: 2.5 mm² Conductor connection cross-section, finely stranded, max.: 6 mm² Conductor connection cross-section, finely stranded, min.: 2.5 mm² Conductor connection cross-section, finest stranded, max.: 6 mm² Conductor connection cross-section, finest stranded, min.: 2.5 mm²
Connection data – contact element Branch / Feed-in Wire connection method: PUSH IN Blade size of operating tool: 0.6 x 3.5 mm Stripping length: 14 mm Number of poles: 5 Conductor connection cross-section, solid, max.: 6 mm² Conductor connection cross-section, solid, min.: 0.5 mm² Conductor connection cross-section, stranded, max.: 6 mm² Conductor connection cross-section, stranded, min.: 0.5 mm² Conductor connection cross-section, finely stranded, max.: 10 mm² Conductor connection cross-section, finely stranded, min.: 0.5 mm² Conductor connection cross-section, finest stranded, max.: 6 mm² Conductor connection cross-section, finest stranded, min.: 0.5 mm² Conductor connection cross-section with wire end ferrule: Type of wire end ferrule: 12 mm with plastic collar Standard: DIN 46228/1 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: 12 mm with plastic collar Standard: DIN 46228/4 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: 8 mm with plastic collar Standard: DIN 46228/1 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: 8 mm with plastic collar Standard: DIN 46228/4 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: Twin wire-end ferrules Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm²
Rated data acc. to IEC for contact element Voltage type: AC, DC Standard: IEC 60947-7-1, IEC 60947-7-2 Rated voltage: 800 V Rated impulse withstand voltage: 8 kV Rated current (3 loaded poles): 41 A Rated current (4 loaded poles): 25 A
Rated data acc. to IEC for fuse plug Voltage type: AC Number of phases: 3 Standard: IEC 61984, IEC 60947-7-3 Rated voltage: 36 V Rated impulse withstand voltage: 6 kV Rated current: 12 A
Rated data acc. to IEC for plug-in connector Voltage type: DC Standard: IEC 60947-7-1, IEC 60947-7-2, IEC 61984 Rated voltage: 690 V Rated impulse withstand voltage: 8 kV Rated current (3 loaded poles): 32 A Rated current (4 loaded poles): 25 A
Rated data acc. to UL for contact element Standard: UL 1059 Note: for use with UL-listed TC-ER cables Conductor connection cross-section, AWG, max.: AWG 10 Conductor connection cross-section, AWG, min.: AWG 14 Rated voltage: 600 V Rated current: 30 A
Rated data acc. to UL for fuse plug Rated voltage: 600 V Note: for use with UL-listed TC-ER cables Conductor connection cross-section, AWG, min.: AWG 16 Conductor connection cross-section, AWG, max.: AWG 12 Standard: UL 1059 Rated current: 20 A
Rated data acc. to UL for plug-in connector Standard: UL 1059 Note: for use with UL-listed TC-ER cables Conductor connection cross-section, AWG, max.: AWG 12 Conductor connection cross-section, AWG, min.: AWG 16 Rated voltage: 600 V Rated current: 20 A
Standards UL 508

Reviews

There are no reviews yet.

Be the first to review “Weidmueller FP PRO TOP3 24/20 2PIOL”

Your email address will not be published. Required fields are marked *