Dragline cable, M12 X-type IP 67 straight male, M12 X-type IP 67 straight male, Cat.6 (ISO/IEC 11801), PUR, 7.5 m
Technical Specifications:
| Length | 7.5 m |
| Length (inches) | 295.276 inch |
| Net weight | 383 g |
| Operating temperature | -40 °C…80 °C |
| Installation temperature | -30 °C…70 °C |
| RoHS Compliance Status | Compliant |
| REACH SVHC | Lead 7439-92-1 |
| Arrangement of wire cores | Twisted pair |
| Colour sequence or wires – wire pairs | white – blue, white – orange, white – green, white – brown |
| Complete shielding | Shielding braid made from copper wiring |
| Copper diameter | 0.55 µm |
| Cross-section | 4*2*AWG 26/19 – 4*2*0.128 mm² |
| Insulation | PP |
| Insulation cross-section | 0.98 mm |
| Material sheath | PUR |
| Number of wires | 8 |
| Sheath diameter, max. | 7.8 mm |
| Sheathing colour | green (RAL 6018) |
| Shielding | S/FTP |
| Strands | 19 |
| Wire material | Stranded tin-plated copper wire |
| Wire pair shielding | Aluminium foil |
| Category | Cat.6 (ISO/IEC 11801) |
| Characteristic impedance | 100 ± 15 Ω at 1–100 MHz |
| Loop resistance | 280 Ω/km |
| Signal propagation time | 5.34 ns/m |
| Test voltage wire-wire-shield | 700 Vrms, 50 Hz, 1 min |
| Transfer impedance | max. 30 mΩ/m at 10 MHz |
| Transmission rate | 10 Gbit/s |
| Abrasion resistance | very good |
| Halogen | halogen-free |
| Min. bending radius, once only | 4 x cable diameter |
| Min. bending radius, repetitive | 7.5 x cable diameter |
| Pulling force | ≤ 100 N |
| Resistance to oils | in accordance with IEC 60811-2-1; acc. to CSA 22.2, 4 days/100°C |
| Resistance to spread of flame | in accordance with IEC 60332-1-2 in accordance with UL 1581 VW-1 and CSA FT1 |
| UV-resistant | Yes |
| Plug left | M12, X-coded, IP67, male contact, straight, plug, Plastic, shielded |
| Plug right | M12, X-coded, IP67, male contact, straight, plug, Plastic, shielded |





Reviews