Printed circuit board terminals, 5.00 mm, Number of poles: 22, 180°, Solder pin length (l): 3.2 mm, tinned, orange, Clamping yoke connection, Clamping range, max. : 6 mm², Box

Technical Specifications:

Depth 17.1 mm
Depth (inches) 0.673 inch
Height 14.2 mm
Height (inches) 0.559 inch
Height of lowest version 11 mm
Width 110 mm
Width (inches) 4.331 inch
Net weight 31.79 g
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Product family OMNIMATE Signal – series LL
Wire connection method Clamping yoke connection
Property, clamping point WireReady
Mounting onto the PCB THT solder connection
Conductor outlet direction 180°
Pitch in mm (P) 5 mm
Pitch in inches (P) 0.197 “
Number of poles 22
Pin series quantity 1
Fitted by customer Yes
Number of rows 1
Max. adjacent poles per row 24
Solder pin length (l) 3.2 mm
Solder pin dimensions 0.75 x 0.9 mm
Solder eyelet hole diameter (D) 1.3 mm
Solder eyelet hole diameter tolerance (D) + 0,1 mm
Number of solder pins per pole 1
Screwdriver blade 0.6 x 3.5
Screwdriver blade standard DIN 5264
Tightening torque, min. 0.5 Nm
Tightening torque, max. 0.6 Nm
Clamping screw M 3
Stripping length 6 mm
L1 in mm 105 mm
L1 in inches 4.137 “
Touch-safe protection acc. to DIN VDE 0470 IP 20
Touch-safe protection acc. to DIN VDE 57 106 Safe from finger touch
Protection degree IP20
Volume resistance 1.20 mΩ
Insulating material Wemid (PA)
Colour orange
Colour chart (similar) RAL 2000
Insulating material group I
Comparative Tracking Index (CTI) ≥ 600
UL 94 flammability rating V-0
Contact material Copper alloy
Contact surface tinned
Coating 4-6 μm SN
Tinning type matt
Layer structure of solder connection 4…6 µm Sn matt
Storage temperature, min. -40 °C
Storage temperature, max. 70 °C
Operating temperature, min. -50 °C
Operating temperature, max. 120 °C
Temperature range, installation, min. -25 °C
Temperature range, installation, max. 120 °C
Clamping range, min. 0.13 mm²
Clamping range, max. 6 mm²
Wire connection cross section AWG, min. AWG 26
Wire connection cross section AWG, max. AWG 12
Solid, min. H05(07) V-U 0.5 mm²
Solid, max. H05(07) V-U 6 mm²
Flexible, min. H05(07) V-K 0.5 mm²
Flexible, max. H05(07) V-K 4 mm²
w. plastic collar ferrule, DIN 46228 pt 4, min. 0.5 mm²
w. plastic collar ferrule, DIN 46228 pt 4, max. 2.5 mm²
w. wire end ferrule, DIN 46228 pt 1, min. 0.5 mm²
w. wire end ferrule, DIN 46228 pt 1, max. 2.5 mm²
Plug gauge in accordance with EN 60999 a x b; ø 2.8 mm x 2.4 mm; 3.0 mm
Clampable conductor Cross-section for conductor connection: Type: fine-wired nominal: 0.5 mm² wire end ferrule: Stripping length: nominal: 8 mm Recommended wire-end ferrule: 0409500000 Stripping length: nominal: 6 mm Recommended wire-end ferrule: 0282600000 Cross-section for conductor connection: Type: fine-wired nominal: 0.75 mm² wire end ferrule: Stripping length: nominal: 8 mm Recommended wire-end ferrule: 0409600000 Stripping length: nominal: 6 mm Recommended wire-end ferrule: 0282700000 Cross-section for conductor connection: Type: fine-wired nominal: 1 mm² wire end ferrule: Stripping length: nominal: 8 mm Recommended wire-end ferrule: 0409700000 Stripping length: nominal: 6 mm Recommended wire-end ferrule: 0372600000
Reference text Length of ferrules is to be chosen depending on the product and the rated voltage. The outside diameter of the plastic collar should not be larger than the pitch (P)
tested acc. to standard IEC 60664-1 IEC 61984
Rated current, min. number of poles (Tu=20°C) 32.5 A
Rated current, max. number of poles (Tu=20°C) 26 A
Rated current, min. number of poles (Tu=40°C) 27.5 A
Rated current, max. number of poles (Tu=40°C) 22 A
Rated voltage for surge voltage class / pollution degree II/2 500 V
Rated voltage for surge voltage class / pollution degree III/2 320 V
Rated voltage for surge voltage class / pollution degree III/3 250 V
Rated impulse voltage for surge voltage class/ pollution degree II/2 4 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2 4 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3 4 kV
Short-time withstand current resistance 3 x 1s with 120 A
Rated voltage (Use group B / CSA) 300 V
Rated voltage (Use group D / CSA) 300 V
Rated current (Use group B / CSA) 20 A
Rated current (Use group D / CSA) 10 A
Wire cross-section, AWG, min. AWG 26
Wire cross-section, AWG, max. AWG 12
Institute (UR) UR
Certificate No. (UR) E60693
Rated voltage (Use group B / UL 1059) 300 V
Rated voltage (Use group D / UL 1059) 300 V
Rated current (Use group B / UL 1059) 20 A
Rated current (Use group D / UL 1059) 10 A
Wire cross-section, AWG, min. AWG 26
Wire cross-section, AWG, max. AWG 12
Reference to approval values Specifications are maximum values, details – see approval certificate.
Packaging Box
VPE length 338 mm
VPE width 130 mm
VPE height 20 mm
Test Durability of markings Test: mark of origin, type identification, type of material, approval marking UL, approval marking CSA, durability Evaluation: available
Test Clampable cross section Standard: IEC 60999-1 section 7 and 9.1 / 11.99, IEC 60947-1 section 8.2.4.5.1 / 03.11 Conductor type: Type of conductor and conductor cross-section: solid 0,13 mm², flexible 0,13 mm², solid 4 mm², flexible 4 mm², AWG 26/1, AWG 26/19, AWG 12/1, AWG 12/19
Test for damage to and accidental loosening of conductors Standard: IEC 60999-1 section 9.4 / 11.99 Requirement: 0.2 kg Conductor type: Type of conductor and conductor cross-section: AWG 26/1 Type of conductor and conductor cross-section: AWG 26/19 Evaluation: passed Requirement: 0.3 kg Conductor type: Type of conductor and conductor cross-section: H05V-U0.5 Type of conductor and conductor cross-section: H05V-K0.5 Evaluation: passed Requirement: 0.9 kg Conductor type: Type of conductor and conductor cross-section: H07V-U4.0 Type of conductor and conductor cross-section: H07V-K4.0 Type of conductor and conductor cross-section: AWG 12/1 Type of conductor and conductor cross-section: AWG 12/19 Evaluation: passed
Pull-out test Standard: IEC 60999-1 section 9.5 / 11.99 Requirement: ≥10 N Conductor type: Type of conductor and conductor cross-section: AWG 26/1 Type of conductor and conductor cross-section: AWG 26/19 Evaluation: passed Requirement: ≥20 N Conductor type: Type of conductor and conductor cross-section: H05V-U0.5 Type of conductor and conductor cross-section: H05V-K0.5 Evaluation: passed Requirement: ≥60 N Conductor type: Type of conductor and conductor cross-section: H07V-U4.0 Type of conductor and conductor cross-section: H07V-K4.0 Type of conductor and conductor cross-section: AWG 12/1 Type of conductor and conductor cross-section: AWG 12/19 Evaluation: passed
IPC conformity Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 “Class 2”. Further claims on the products can be evaluated on request.
Notes Rated current related to rated cross-section & min. No. of poles. Wire end ferrule without plastic collar to DIN 46228/1 Wire end ferrule with plastic collar to DIN 46228/4 P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months