Weidmueller LL 6.35/11/90V 5.0SN BK BX

Request a price

LL 6.35/11/90V 5.0SN BK BX

SKU: 1356940000.0 Category: Brand:

Printed circuit board terminals, 6.35 mm, Number of poles: 11, 90°, Solder pin length (l): 5 mm, tinned, black, Clamping yoke connection, Clamping range, max. : 6 mm², Box

Technical Specifications:

Depth 15.85 mm
Depth (inches) 0.624 inch
Height 33.5 mm
Height (inches) 1.319 inch
Height of lowest version 28.5 mm
Width 70.45 mm
Width (inches) 2.774 inch
Net weight 31.28 g
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Product family OMNIMATE Signal – series LL
Wire connection method Clamping yoke connection
Mounting onto the PCB THT solder connection
Conductor outlet direction 90°
Pitch in mm (P) 6.35 mm
Pitch in inches (P) 0.25 “
Number of poles 11
Pin series quantity 1
Fitted by customer No
Number of rows 1
Max. adjacent poles per row 24
Solder pin length (l) 5 mm
Solder pin dimensions 1.0 x 0.6 mm
Solder eyelet hole diameter (D) 1.3 mm
Solder eyelet hole diameter tolerance (D) + 0,1 mm
Number of solder pins per pole 1
Screwdriver blade 0.8 x 4.0 PZ 1
Screwdriver blade standard DIN 5264
Tightening torque, min. 0.5 Nm
Tightening torque, max. 0.6 Nm
Clamping screw M 3
Stripping length 8 mm
L1 in mm 63.5 mm
L1 in inches 2.5 “
Touch-safe protection acc. to DIN VDE 0470 IP 20
Touch-safe protection acc. to DIN VDE 57 106 Safe from finger touch
Protection degree IP20
Insulating material Wemid (PA)
Colour black
Colour chart (similar) RAL 9011
Insulating material group I
Comparative Tracking Index (CTI) ≥ 600
UL 94 flammability rating V-0
Contact material Cu-alloy
Contact surface tinned
Coating 4-6 μm SN
Tinning type matt
Layer structure of solder connection 2…4 µm Ni / 4…6 µm Sn matt
Storage temperature, min. -40 °C
Storage temperature, max. 70 °C
Operating temperature, min. -50 °C
Operating temperature, max. 120 °C
Temperature range, installation, min. -25 °C
Temperature range, installation, max. 120 °C
Clamping range, min. 0.18 mm²
Clamping range, max. 6 mm²
Wire connection cross section AWG, min. AWG 26
Wire connection cross section AWG, max. AWG 10
Solid, min. H05(07) V-U 0.18 mm²
Solid, max. H05(07) V-U 6 mm²
Stranded, min. H07V-R 0.22 mm²
Stranded, max. H07V-R 4 mm²
Flexible, min. H05(07) V-K 0.22 mm²
Flexible, max. H05(07) V-K 4 mm²
w. plastic collar ferrule, DIN 46228 pt 4, min. 0.5 mm²
w. plastic collar ferrule, DIN 46228 pt 4, max. 2.5 mm²
w. wire end ferrule, DIN 46228 pt 1, min. 0.5 mm²
w. wire end ferrule, DIN 46228 pt 1, max. 4 mm²
Plug gauge in accordance with EN 60999 a x b; ø 3.6 mm x 3.1 mm; 2.7 mm
Clampable conductor Cross-section for conductor connection: Type: fine-wired nominal: 0.5 mm² wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 0690700000 Cross-section for conductor connection: Type: fine-wired nominal: 0.75 mm² wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9021040000 Cross-section for conductor connection: Type: fine-wired nominal: 1 mm² wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 0463000000 Cross-section for conductor connection: Type: fine-wired nominal: 1.5 mm² wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9019120000 Stripping length: nominal: 7 mm Recommended wire-end ferrule: 0372700000 Cross-section for conductor connection: Type: fine-wired nominal: 2.5 mm² wire end ferrule: Stripping length: nominal: 7 mm Recommended wire-end ferrule: 0373000000 Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9019160000
Reference text Length of ferrules is to be chosen depending on the product and the rated voltage. The outside diameter of the plastic collar should not be larger than the pitch (P)
tested acc. to standard IEC 60664-1 IEC 61984
Rated current, min. number of poles (Tu=20°C) 32 A
Rated current, max. number of poles (Tu=20°C) 32 A
Rated current, min. number of poles (Tu=40°C) 32 A
Rated current, max. number of poles (Tu=40°C) 32 A
Rated voltage for surge voltage class / pollution degree II/2 1,000 V
Rated voltage for surge voltage class / pollution degree III/2 1,000 V
Rated voltage for surge voltage class / pollution degree III/3 800 V
Rated impulse voltage for surge voltage class/ pollution degree II/2 8 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2 8 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3 8 kV
Short-time withstand current resistance 3 x 1s with 120 A
Institute (CSA) CSA
Certificate No. (CSA) 200039-1202191
Rated voltage (Use group B / CSA) 600 V
Rated voltage (Use group C / CSA) 600 V
Rated voltage (Use group D / CSA) 600 V
Rated current (Use group B / CSA) 30 A
Rated current (Use group C / CSA) 30 A
Rated current (Use group D / CSA) 5 A
Wire cross-section, AWG, min. AWG 26
Wire cross-section, AWG, max. AWG 10
Reference to approval values Specifications are maximum values, details – see approval certificate.
Institute (cURus) CURUS
Certificate No. (cURus) E60693
Rated voltage (Use group B / UL 1059) 600 V
Rated voltage (Use group C / UL 1059) 600 V
Rated voltage (Use group D / UL 1059) 600 V
Rated current (Use group B / UL 1059) 30 A
Rated current (Use group C / UL 1059) 30 A
Rated current (Use group D / UL 1059) 5 A
Wire cross-section, AWG, min. AWG 26
Wire cross-section, AWG, max. AWG 10
Reference to approval values Specifications are maximum values, details – see approval certificate.
Packaging Box
VPE length 411 mm
VPE width 161 mm
VPE height 39 mm
Test Clampable cross section Standard: IEC 60999-1 section 7 and 9.1 / 11.99, IEC 60947-1 section 8.2.4.5.1 / 03.11
IPC conformity Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 “Class 2”. Further claims on the products can be evaluated on request.
Notes Additional variants on request Rated current related to rated cross-section & min. No. of poles. Wire end ferrule without plastic collar to DIN 46228/1 Wire end ferrule with plastic collar to DIN 46228/4 P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months

Reviews

There are no reviews yet.

Be the first to review “Weidmueller LL 6.35/11/90V 5.0SN BK BX”

Your email address will not be published. Required fields are marked *