Weidmueller LMF 7.50/12/180 3.5SN OR BX

Request a price

LMF 7.50/12/180 3.5SN OR BX

SKU: 2774640000.0 Category: Brand:

Printed circuit board terminals, 7.50 mm, Number of poles: 12, 180°, Solder pin length (l): 3.5 mm, tinned, orange, PUSH IN with actuator, Box

Technical Specifications:

Depth 14.8 mm
Depth (inches) 0.583 inch
Height 22.7 mm
Height (inches) 0.894 inch
Width 90.2 mm
Width (inches) 3.551 inch
Net weight 11 g
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Product family OMNIMATE Signal – series LMF
Wire connection method PUSH IN with actuator
Mounting onto the PCB THT solder connection
Conductor outlet direction 180°
Pitch in mm (P) 7.5 mm
Pitch in inches (P) 0.295 “
Number of poles 12
Pin series quantity 2
Number of rows 1
Solder pin length (l) 3.5 mm
Solder pin dimensions 0.6 x 0.8 mm
Stripping length 10 mm
Touch-safe protection acc. to DIN VDE 0470 IP 20
Touch-safe protection acc. to DIN VDE 57 106 Safe from finger touch
Insulating material Wemid (PA)
Colour orange
Colour chart (similar) RAL 2000
Comparative Tracking Index (CTI) ≥ 600
UL 94 flammability rating V-0
Contact material Cu-alloy
Contact surface tinned
Coating 4-6 μm SN
Layer structure of solder connection 4…8 µm Sn matt
Storage temperature, min. -40 °C
Storage temperature, max. 70 °C
Operating temperature, min. -50 °C
Operating temperature, max. 120 °C
Wire connection cross section AWG, min. AWG 24
Wire connection cross section AWG, max. AWG 12
Solid, min. H05(07) V-U 0.5 mm²
Solid, max. H05(07) V-U 2.5 mm²
Flexible, min. H05(07) V-K 0.25 mm²
Flexible, max. H05(07) V-K 2.5 mm²
w. wire end ferrule, DIN 46228 pt 1, min. 0.25 mm²
w. wire end ferrule, DIN 46228 pt 1, max. 2.5 mm²
Reference text Length of ferrules is to be chosen depending on the product and the rated voltage. The outside diameter of the plastic collar should not be larger than the pitch (P)
tested acc. to standard IEC 60664-1 IEC 61984
Rated current, min. number of poles (Tu=20°C) 24 A
Rated current, max. number of poles (Tu=20°C) 19 A
Rated current, min. number of poles (Tu=40°C) 21 A
Rated current, max. number of poles (Tu=40°C) 24 A
Rated voltage for surge voltage class / pollution degree II/2 1,000 V
Rated voltage for surge voltage class / pollution degree III/2 600 V
Rated voltage for surge voltage class / pollution degree III/3 500 V
Rated impulse voltage for surge voltage class/ pollution degree II/2 6 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2 6 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3 6 kV
Short-time withstand current resistance 3 x 1s with 120 A
Rated voltage (Use group B / CSA) 300 V
Rated voltage (Use group D / CSA) 300 V
Rated current (Use group B / CSA) 20 A
Rated current (Use group D / CSA) 10 A
Wire cross-section, AWG, min. AWG 24
Wire cross-section, AWG, max. AWG 12
Rated voltage (Use group B / UL 1059) 300 V
Rated voltage (Use group D / UL 1059) 300 V
Rated current (Use group B / UL 1059) 20 A
Rated current (Use group D / UL 1059) 10 A
Wire cross-section, AWG, min. AWG 24
Wire cross-section, AWG, max. AWG 12
Packaging Box
VPE length 338 mm
VPE width 130 mm
VPE height 27 mm
Test Durability of markings Standard: IEC 61984 section 6.2 and 7.3.2 / 10.11 Test: mark of origin, type identification, approval marking UL, approval marking CSA, durability Evaluation: available
Test Clampable cross section Conductor type: Type of conductor and conductor cross-section: solid 0.2 mm² Type of conductor and conductor cross-section: solid 2.5 mm² Type of conductor and conductor cross-section: stranded 0.2 mm² Type of conductor and conductor cross-section: flexible 4 mm² Type of conductor and conductor cross-section: AWG 12/7 Type of conductor and conductor cross-section: AWG 24/11 Evaluation: passed
Test for damage to and accidental loosening of conductors Standard: IEC 60999-1 section 9.4 / 11.99 Requirement: 0.2 kg Conductor type: Type of conductor and conductor cross-section: solid 0.2 mm² Type of conductor and conductor cross-section: stranded 0.2 mm² Evaluation: passed Requirement: 0.7 kg Conductor type: Type of conductor and conductor cross-section: solid 2.5 mm² Evaluation: passed Requirement: 0,9 kg Conductor type: Type of conductor and conductor cross-section: flexible 4 mm² Evaluation: passed
Pull-out test Standard: IEC 60999-1 section 9.5 / 11.99 Requirement: ≥10 N Conductor type: Type of conductor and conductor cross-section: solid 0.2 mm² Type of conductor and conductor cross-section: stranded 0.2 mm² Evaluation: passed Requirement: ≥50 N Conductor type: Type of conductor and conductor cross-section: solid 2.5 mm² Evaluation: passed Requirement: ≥ 60 N Conductor type: Type of conductor and conductor cross-section: flexible 4 mm² Evaluation: passed
IPC conformity Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 “Class 2”. Further claims on the products can be evaluated on request.
Notes Additional variants on request Rated current related to rated cross-section & min. No. of poles. Wire end ferrule without plastic collar to DIN 46228/1 Wire end ferrule with plastic collar to DIN 46228/4 P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. The test point can only be used as potential-pickup point. Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months