Printed circuit board terminals, 5.08 mm, Number of poles: 3, 180°, Solder pin length (l): 1.5 mm, black, PUSH IN with actuator, Clamping range, max. : 1.5 mm², Tube
Technical Specifications:
| Depth | 7.8 mm |
| Depth (inches) | 0.307 inch |
| Height | 15.5 mm |
| Height (inches) | 0.61 inch |
| Height of lowest version | 14 mm |
| Width | 14.36 mm |
| Width (inches) | 0.565 inch |
| Net weight | 2.244 g |
| Continuous operating temp., max. | 120 °C |
| RoHS Compliance Status | Compliant without exemption |
| REACH SVHC | No SVHC above 0.1 wt% |
| Product family | OMNIMATE Signal – series LSF |
| Wire connection method | PUSH IN with actuator |
| Mounting onto the PCB | THT/THR solder connection |
| Conductor outlet direction | 180° |
| Pitch in mm (P) | 5.08 mm |
| Pitch in inches (P) | 0.2 “ |
| Number of poles | 3 |
| Pin series quantity | 1 |
| Number of rows | 1 |
| Solder pin length (l) | 1.5 mm |
| Solder pin dimensions | 0.35 x 0.8 mm |
| L1 in mm | 10.16 mm |
| L1 in inches | 0.4 “ |
| Protection degree | IP30 when fully mounted |
| Insulating material | LCP GF |
| Colour | black |
| Colour chart (similar) | RAL 9011 |
| Moisture Level (MSL) | 1 |
| UL 94 flammability rating | V-0 |
| Contact material | Cu-alloy |
| Layer structure of solder connection | 4…6 µm Sn matt |
| Storage temperature, min. | -40 °C |
| Storage temperature, max. | 70 °C |
| Operating temperature, min. | -50 °C |
| Operating temperature, max. | 120 °C |
| Clamping range, min. | 0.13 mm² |
| Clamping range, max. | 1.5 mm² |
| Solid, min. H05(07) V-U | 0.2 mm² |
| Solid, max. H05(07) V-U | 1.5 mm² |
| Flexible, min. H05(07) V-K | 0.2 mm² |
| Flexible, max. H05(07) V-K | 1.5 mm² |
| w. plastic collar ferrule, DIN 46228 pt 4, min. | 0.25 mm² |
| w. plastic collar ferrule, DIN 46228 pt 4, max. | 0.75 mm² |
| w. wire end ferrule, DIN 46228 pt 1, min. | 0.25 mm² |
| w. wire end ferrule, DIN 46228 pt 1, max. | 1.5 mm² |
| Clampable conductor | Cross-section for conductor connection: nominal: 0.25 mm² wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9025760000 Cross-section for conductor connection: nominal: 0.34 mm² wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9025770000 Cross-section for conductor connection: nominal: 0.5 mm² wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 0690700000 Cross-section for conductor connection: nominal: 0.75 mm² wire end ferrule: Stripping length: nominal: 10 mm Recommended wire-end ferrule: 9021040000 Cross-section for conductor connection: nominal: 1 mm² wire end ferrule: Stripping length: nominal: 12 mm Recommended wire-end ferrule: 9019100000 Cross-section for conductor connection: nominal: 1.5 mm² wire end ferrule: Stripping length: nominal: 12 mm Recommended wire-end ferrule: 9028350000 |
| Reference text | Length of ferrules is to be chosen depending on the product and the rated voltage. The outside diameter of the plastic collar should not be larger than the pitch (P) |
| Rated current, max. number of poles (Tu=20°C) | 17.5 A |
| Rated current, min. number of poles (Tu=40°C) | 17.5 A |
| Rated voltage for surge voltage class / pollution degree II/2 | 630 V |
| Rated voltage for surge voltage class / pollution degree III/2 | 630 V |
| Rated impulse voltage for surge voltage class/ pollution degree II/2 | 4 kV |
| Rated impulse voltage for surge voltage class/ pollution degree III/2 | 6 kV |
| Institute (CSA) | CSA |
| Certificate No. (CSA) | 200039-1664286 |
| Rated voltage (Use group B / CSA) | 300 V |
| Rated voltage (Use group D / CSA) | 300 V |
| Rated current (Use group B / CSA) | 10 A |
| Rated current (Use group D / CSA) | 10 A |
| Wire cross-section, AWG, min. | AWG 28 |
| Wire cross-section, AWG, max. | AWG 14 |
| Reference to approval values | Specifications are maximum values, details – see approval certificate. |
| Institute (cURus) | CURUS |
| Certificate No. (cURus) | E60693 |
| Rated voltage (Use group B / UL 1059) | 300 V |
| Rated voltage (Use group D / UL 1059) | 300 V |
| Rated current (Use group B / UL 1059) | 12 A |
| Rated current (Use group D / UL 1059) | 10 A |
| Wire cross-section, AWG, min. | AWG 28 |
| Wire cross-section, AWG, max. | AWG 14 |
| Reference to approval values | Specifications are maximum values, details – see approval certificate. |
| Packaging | Tube |
| VPE length | 557 mm |
| VPE width | 21 mm |
| VPE height | 15 mm |
| Test Durability of markings | Standard: DIN EN 60512-1-1 / 01.03 Test: mark of origin, type identification, pitch, approval marking UL, durability Evaluation: available |
| Test Clampable cross section | Standard: DIN EN 60999-1 section 7 and 9.1 / 12.00, DIN EN 60947-1 section 8.2.4.5.1 / 12.02 Conductor type: Type of conductor and conductor cross-section: solid 0.14 mm² Type of conductor and conductor cross-section: stranded 0.14 mm² Type of conductor and conductor cross-section: solid 1.5 mm² Type of conductor and conductor cross-section: stranded 1.5 mm² Type of conductor and conductor cross-section: AWG 24/1 Type of conductor and conductor cross-section: AWG 24/19 Type of conductor and conductor cross-section: AWG 16/1 Type of conductor and conductor cross-section: AWG 16/19 Evaluation: passed |
| Test for damage to and accidental loosening of conductors | Standard: DIN EN 60999-1 section 9.4 / 12.00 Requirement: 0.2 kg Conductor type: Type of conductor and conductor cross-section: AWG 28/1 Type of conductor and conductor cross-section: AWG 28/19 Evaluation: passed Requirement: 0.3 kg Conductor type: Type of conductor and conductor cross-section: stranded 0.25 mm² Type of conductor and conductor cross-section: solid 0.5 mm² Evaluation: passed Requirement: 0.4 kg Conductor type: Type of conductor and conductor cross-section: solid 1.5 mm² Type of conductor and conductor cross-section: stranded 1.5 mm² Type of conductor and conductor cross-section: AWG 16/1 Type of conductor and conductor cross-section: AWG 16/19 Evaluation: passed |
| Pull-out test | Standard: DIN EN 60999-1 section 9.5 / 12.00 Requirement: ≥10 N Conductor type: Type of conductor and conductor cross-section: AWG 24/1 Type of conductor and conductor cross-section: AWG 24/19 Evaluation: passed Requirement: ≥20 N Conductor type: Type of conductor and conductor cross-section: stranded 0.25 mm² Type of conductor and conductor cross-section: H05V-U0.5 Evaluation: passed Requirement: ≥40 N Conductor type: Type of conductor and conductor cross-section: H07V-U1.5 Type of conductor and conductor cross-section: H07V-K1.5 Type of conductor and conductor cross-section: AWG 16/1 Type of conductor and conductor cross-section: AWG 16/19 Evaluation: passed |
| IPC conformity | Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 “Class 2”. Further claims on the products can be evaluated on request. |
| Notes | Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months |





Reviews
There are no reviews yet.