Weidmueller LUF 10.00/03/90V 5.0SN BK BX

Request a price

LUF 10.00/03/90V 5.0SN BK BX

SKU: 2453700000.0 Category: Brand:

Printed circuit board terminals, 10.00 mm, Number of poles: 3, 90°, Solder pin length (l): 5 mm, black, PUSH IN with actuator, Clamping range, max. : 16 mm², Box

Technical Specifications:

Depth 26.45 mm
Depth (inches) 1.041 inch
Height 47.03 mm
Height (inches) 1.852 inch
Height of lowest version 42.03 mm
Width 31.58 mm
Width (inches) 1.243 inch
Net weight 31.6 g
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Product family OMNIMATE Power – series LU
Wire connection method PUSH IN with actuator
Mounting onto the PCB THT solder connection
Conductor outlet direction 90°
Pitch in mm (P) 10 mm
Pitch in inches (P) 0.394 “
Number of poles 3
Pin series quantity 1
Fitted by customer No
Number of rows 1
Solder pin length (l) 5 mm
Solder pin dimensions d = 1.2 mm Octagonal
Solder eyelet hole diameter (D) 1.6 mm
Solder eyelet hole diameter tolerance (D) + 0,1 mm
Number of solder pins per pole 2
Screwdriver blade 0.8 x 4.0
Stripping length 18 mm
L1 in mm 20 mm
L1 in inches 0.787 “
Touch-safe protection acc. to DIN VDE 0470 IP20 plugged/ IP10 unplugged
Touch-safe protection acc. to DIN VDE 57 106 touch-safe with connected connectors from 6 mm²
Protection degree IP20
Insulating material Wemid (PA)
Colour black
Colour chart (similar) RAL 9011
Insulating material group I
Comparative Tracking Index (CTI) ≥ 600
UL 94 flammability rating V-0
Contact base material E-Cu
Contact material Cu-alloy
Storage temperature, min. -40 °C
Storage temperature, max. 70 °C
Operating temperature, min. -40 °C
Operating temperature, max. 120 °C
Clamping range, min. 0.5 mm²
Clamping range, max. 16 mm²
Solid, min. H05(07) V-U 0.5 mm²
Solid, max. H05(07) V-U 16 mm²
Stranded, min. H07V-R 6 mm²
Stranded, max. H07V-R 25 mm²
Flexible, min. H05(07) V-K 0.5 mm²
Flexible, max. H05(07) V-K 25 mm²
w. plastic collar ferrule, DIN 46228 pt 4, min. 0.5 mm²
w. plastic collar ferrule, DIN 46228 pt 4, max. 16 mm²
w. wire end ferrule, DIN 46228 pt 1, min. 0.5 mm²
w. wire end ferrule, DIN 46228 pt 1, max. 16 mm²
Plug gauge in accordance with EN 60999 a x b; ø 5.3mm (B6)
Clampable conductor Cross-section for conductor connection: Type: fine-wired nominal: 2.5 mm² wire end ferrule: Stripping length: nominal: 20 mm Recommended wire-end ferrule: 9019180000 Stripping length: nominal: 18 mm Recommended wire-end ferrule: 9004090000 Cross-section for conductor connection: Type: fine-wired nominal: 4 mm² wire end ferrule: Stripping length: nominal: 20 mm Recommended wire-end ferrule: 9019210000 Stripping length: nominal: 18 mm Recommended wire-end ferrule: 9004110000 Cross-section for conductor connection: Type: fine-wired nominal: 6 mm² wire end ferrule: Stripping length: nominal: 20 mm Recommended wire-end ferrule: 0565700000 Stripping length: nominal: 18 mm Recommended wire-end ferrule: 9004130000 Cross-section for conductor connection: Type: fine-wired nominal: 10 mm² wire end ferrule: Stripping length: nominal: 21 mm Recommended wire-end ferrule: 0565800000 Stripping length: nominal: 18 mm Recommended wire-end ferrule: 0379300000 Cross-section for conductor connection: Type: fine-wired nominal: 16 mm² wire end ferrule: Stripping length: nominal: 21 mm Recommended wire-end ferrule: 0566000000 Stripping length: nominal: 18 mm Recommended wire-end ferrule: 0375200000 Cross-section for conductor connection: Type: fine-wired nominal: 1.5 mm² wire end ferrule: Stripping length: nominal: 20 mm Recommended wire-end ferrule: 0565600000 Stripping length: nominal: 18 mm Recommended wire-end ferrule: 9004070000
Reference text Length of ferrules is to be chosen depending on the product and the rated voltage. The outside diameter of the plastic collar should not be larger than the pitch (P)
tested acc. to standard IEC 60947-7-4
Rated current, min. number of poles (Tu=20°C) 92 A
Rated current, max. number of poles (Tu=20°C) 80 A
Rated current, min. number of poles (Tu=40°C) 82 A
Rated current, max. number of poles (Tu=40°C) 76 A
Rated voltage for surge voltage class / pollution degree II/2 1,000 V
Rated voltage for surge voltage class / pollution degree III/2 690 V
Rated voltage for surge voltage class / pollution degree III/3 1,000 V
Rated impulse voltage for surge voltage class/ pollution degree II/2 6 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2 6 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3 8 kV
Rated voltage (Use group B / CSA) 600 V
Rated voltage (Use group C / CSA) 600 V
Rated voltage (Use group D / CSA) 600 V
Rated current (Use group B / CSA) 58 A
Rated current (Use group C / CSA) 58 A
Rated current (Use group D / CSA) 5 A
Wire cross-section, AWG, min. AWG 18
Wire cross-section, AWG, max. AWG 6
Institute (cURus) CURUS
Certificate No. (cURus) E60693
Rated voltage (Use group B / UL 1059) 600 V
Rated voltage (Use group C / UL 1059) 600 V
Rated voltage (Use group D / UL 1059) 600 V
Rated current (Use group B / UL 1059) 58 A
Rated current (Use group C / UL 1059) 58 A
Rated current (Use group D / UL 1059) 5 A
Wire cross-section, AWG, min. AWG 18
Wire cross-section, AWG, max. AWG 6
Reference to approval values Specifications are maximum values, details – see approval certificate.
Packaging Box
VPE length 278 mm
VPE width 169 mm
VPE height 49 mm
Test Durability of markings Standard: IEC 60947-1 section 8.2.4.5.1 / 06.07, IEC 60512-1-1:2002-02 Test: mark of origin, type identification, pitch, durability, stripping length Evaluation: available
Test Clampable cross section Standard: IEC 60999-1 section 7 and 9.1 / 11.99, IEC 60947-1 section 8.2.4.5.1 / 03.11 Conductor type: Type of conductor and conductor cross-section: solid 0.5 mm² Type of conductor and conductor cross-section: stranded 0.5 mm² Type of conductor and conductor cross-section: solid 16 mm² Type of conductor and conductor cross-section: stranded 16 mm² Type of conductor and conductor cross-section: H07V-U16 Type of conductor and conductor cross-section: H07V-U6 Type of conductor and conductor cross-section: H07V-K16 Type of conductor and conductor cross-section: AWG 4 Evaluation: passed
Test for damage to and accidental loosening of conductors Standard: IEC 60999-1 section 9.4 / 11.99 Requirement: 0.3 kg Conductor type: Type of conductor and conductor cross-section: AWG 20/1 Type of conductor and conductor cross-section: AWG 20/19 Type of conductor and conductor cross-section: H05V-U0.5 Type of conductor and conductor cross-section: H05V-K0.5 Evaluation: passed Requirement: 2.9 kg Conductor type: Type of conductor and conductor cross-section: H07V-U16 Type of conductor and conductor cross-section: H07V-K16 Evaluation: passed Requirement: 4,5 kg Conductor type: Type of conductor and conductor cross-section: AWG 4/7 Type of conductor and conductor cross-section: AWG 4/19 Evaluation: passed
Pull-out test Standard: IEC 60999-1 section 9.5 / 11.99 Requirement: ≥20 N Conductor type: Type of conductor and conductor cross-section: AWG 20/1 Type of conductor and conductor cross-section: AWG 20/19 Type of conductor and conductor cross-section: H05V-U0.5 Type of conductor and conductor cross-section: H05V-K0.5 Evaluation: passed Requirement: ≥100 N Conductor type: Type of conductor and conductor cross-section: H07V-U16 Type of conductor and conductor cross-section: H07V-K16 Evaluation: passed Requirement: ≥ 135 N Conductor type: Type of conductor and conductor cross-section: AWG 4/7 Type of conductor and conductor cross-section: AWG 4/19 Evaluation: passed
IPC conformity Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 “Class 2”. Further claims on the products can be evaluated on request.
Notes Additional variants on request Rated current related to rated cross-section & min. No. of poles. Wire end ferrule without plastic collar to DIN 46228/1 Wire end ferrule with plastic collar to DIN 46228/4 P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. The test point can only be used as potential-pickup point. The single-position PCB terminal block can be used for voltages up to 1500 V (DC) and 1000 V (AC). The relevant device standard and the appropriate required clearances and creepage distances should be observed in the application Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months

Reviews

There are no reviews yet.

Be the first to review “Weidmueller LUF 10.00/03/90V 5.0SN BK BX”

Your email address will not be published. Required fields are marked *