Weidmueller MCZ PT100/3 CLP -40C…100C

Request a price

MCZ PT100/3 CLP -40C…100C

SKU: 8604430000.0 Category: Brand:

Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA

Technical Specifications:

Depth 63.2 mm
Depth (inches) 2.488 inch
Width 6 mm
Width (inches) 0.236 inch
Length 91 mm
Length (inches) 3.583 inch
Net weight 28.3 g
Storage temperature -25 °C…85 °C
Operating temperature -25 °C…50 °C
SIL in compliance with IEC 61508 None
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 6c, 7a, 7cI
REACH SVHC Lead 7439-92-1
SCIP c2a21576-d875-4548-ae68-5e7f85ddf0c7
Number of inputs 1
Sensor PT100 (3 wire)
Sensor supply 0.8 mA / 9…30 V DC
Temperature input range -40…+100 °C
Load impedance current ≤ 600 Ω
Number of outputs 1
Output current 4…20 mA (current loop) at 9…30V DC
Accuracy Typ.: 0.2 %, máx. 0.5 % v. FSR
Configuration none
Linearity Yes
Long-term drift 0
Nominal power consumption 2 VA
Operating altitude ≤ 2000 m
Protection degree IP20
Rail TS 35
Step response time 10 ms
Temperature coefficient max. ± 250 ppm/K
Voltage supply Output loop powered max. 30 V/ min. 9 V + (20 mA x RL)
EMC standards EN 61000-6
Galvanic isolation Without isolation
Pollution severity 2
Rated voltage 50 V
Surge voltage category I
Type of connection Tension-clamp connection
Clamping range, rated connection 1.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 1.5 mm²
Wire connection cross section AWG, min. AWG 26
Wire connection cross section AWG, max. AWG 16
Wire cross-section, solid, min. 0.5 mm²
Wire cross-section, solid, max. 1.5 mm²
Wire cross-section, solid, min. (AWG) AWG 26
Wire cross-section, solid, max. (AWG) AWG 16
Wire connection cross section, finely stranded, min. 0.5 mm²
Wire connection cross section, finely stranded, max. 1.5 mm²
Wire cross-section, finely stranded, min. (AWG) AWG 26
Wire cross-section, finely stranded, max. (AWG) AWG 16
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min. 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max. 1.5 mm²
Long specification PT100 temperature measuring transformer, output-loop powered,3-wire connection technologyRTD measuring transformer in 6 mm width, 4…20 mA output-loop poweredwithout electrical isolation, for transmitting PT100 2-/3-wire signals.Input temperature range -40…+100 °C.Add-on housing for TS35 rail mountingDimensions: L/W/H 91/ 6/ 63.2 mmTension-clamp connection / Nominal cross-section 1.5 mm2Protection degree: IP 20 Input PT100, 2-/3-wireOutput 4…20 mALoad resistance Transmission error Auxiliary power via 4…20 mA current loopAmbient temperature range 0°C…+50 °C< 0,2 % v. E.Isolation no electrical isolationApprovals cURus, CSATypeMCZ PT100/3 CLP -40C…+100C
Short specification PT100 temperature measuring transformer, output-loop powered, 3-wire connection technologyRTD measuring transformer in 6 mm width, 4…20 mA output-loop powered without electrical isolation, for transmitting PT100 2-/3-wire signals. Input temperature range -40…+100 °C.

Reviews

There are no reviews yet.

Be the first to review “Weidmueller MCZ PT100/3 CLP -40C…100C”

Your email address will not be published. Required fields are marked *