OMNIMATE Power – series PGK, Feed-through terminal, Rated cross-section: 4 mm², Wemid (PA), Direct mounting, Feed-through (bushing)
Technical Specifications:
| Height | 24.3 mm |
| Height (inches) | 0.957 inch |
| Height of lowest version | 24.3 mm |
| Width | 5.1 mm |
| Width (inches) | 0.201 inch |
| Length | 5.1 mm |
| Length (inches) | 0.201 inch |
| Net weight | 6.342 g |
| RoHS Compliance Status | Compliant without exemption |
| REACH SVHC | No SVHC above 0.1 wt% |
| Product family | OMNIMATE Power – series PGK |
| Wire connection method | PUSH IN without actuator |
| Conductor outlet direction | 180° |
| Number of poles | 1 |
| Pin series quantity | 1 |
| Fitted by customer | Yes |
| Screwdriver blade | 0.4 x 2.5 |
| Stripping length | 12 mm |
| Touch-safe protection acc. to DIN VDE 0470 | IP 20 |
| Protection degree | IP20 |
| Type of connection 1 | PUSH IN |
| Type of connection 2 | PUSH IN |
| Insulating material | Wemid (PA) |
| Colour | black |
| Colour chart (similar) | RAL 9011 |
| UL 94 flammability rating | V-0 |
| Contact material | Cu-alloy |
| Contact surface | tinned |
| Storage temperature, min. | -40 °C |
| Storage temperature, max. | 70 °C |
| Operating temperature, min. | -50 °C |
| Operating temperature, max. | 120 °C |
| Temperature range, installation, min. | -25 °C |
| Temperature range, installation, max. | 120 °C |
| Clamping range, min. | 0.5 mm² |
| Clamping range, max. | 4 mm² |
| Wire connection cross section AWG, min. | AWG 24 |
| Wire connection cross section AWG, max. | AWG 10 |
| Solid, min. H05(07) V-U | 0.5 mm² |
| Solid, max. H05(07) V-U | 4 mm² |
| Flexible, min. H05(07) V-K | 0.5 mm² |
| Flexible, max. H05(07) V-K | 4 mm² |
| w. plastic collar ferrule, DIN 46228 pt 4, min. | 0.5 mm² |
| w. plastic collar ferrule, DIN 46228 pt 4, max. | 2.5 mm² |
| w. wire end ferrule, DIN 46228 pt 1, min. | 0.5 mm² |
| w. wire end ferrule, DIN 46228 pt 1, max. | 4 mm² |
| Clampable conductor | Cross-section for conductor connection: Type: fine-wired nominal: 0.5 mm² wire end ferrule: Stripping length: nominal: 14 mm Recommended wire-end ferrule: 1076980000 Cross-section for conductor connection: Type: fine-wired nominal: 1 mm² wire end ferrule: Stripping length: nominal: 15 mm Recommended wire-end ferrule: 9025930000 Cross-section for conductor connection: Type: fine-wired nominal: 1.5 mm² wire end ferrule: Stripping length: nominal: 15 mm Recommended wire-end ferrule: 9019140000 Stripping length: nominal: 12 mm Recommended wire-end ferrule: 9004060000 Cross-section for conductor connection: Type: fine-wired nominal: 0.75 mm² wire end ferrule: Stripping length: nominal: 14 mm Recommended wire-end ferrule: 9025910000 Cross-section for conductor connection: Type: fine-wired nominal: 2.5 mm² wire end ferrule: Stripping length: nominal: 14 mm Recommended wire-end ferrule: 9019170000 Stripping length: nominal: 12 mm Recommended wire-end ferrule: 0186100000 Cross-section for conductor connection: Type: fine-wired nominal: 4 mm² wire end ferrule: Stripping length: nominal: 12 mm Recommended wire-end ferrule: 0244100000 |
| Reference text | Length of ferrules is to be chosen depending on the product and the rated voltage. The outside diameter of the plastic collar should not be larger than the pitch (P) |
| tested acc. to standard | IEC 60664-1 |
| Rated current, min. number of poles (Tu=20°C) | 32 A |
| Rated current, max. number of poles (Tu=20°C) | 32 A |
| Rated voltage for surge voltage class / pollution degree III/3 | 500 V |
| Rated impulse voltage for surge voltage class/ contamination degree III/3 | 6 kV |
| Institute (CSA) | CSA |
| Certificate No. (CSA) | 200039-70000589 |
| Rated voltage (Use group B / CSA) | 300 V |
| Rated voltage (Use group C / CSA) | 150 V |
| Rated voltage (Use group D / CSA) | 300 V |
| Rated current (Use group B / CSA) | 30 A |
| Rated current (Use group C / CSA) | 30 A |
| Rated current (Use group D / CSA) | 10 A |
| Wire cross-section, AWG, min. | AWG 24 |
| Wire cross-section, AWG, max. | AWG 10 |
| Reference to approval values | Specifications are maximum values, details – see approval certificate. |
| Institute (cURus) | CURUS |
| Certificate No. (cURus) | E60693 |
| Rated voltage (Use group B / UL 1059) | 300 V |
| Rated voltage (Use group C / UL 1059) | 150 V |
| Rated voltage (Use group D / UL 1059) | 300 V |
| Rated current (Use group B / UL 1059) | 30 A |
| Rated current (Use group C / UL 1059) | 30 A |
| Rated current (Use group D / UL 1059) | 10 A |
| Wire cross-section, AWG, min. | AWG 24 |
| Wire cross-section, AWG, max. | AWG 10 |
| Reference to approval values | Specifications are maximum values, details – see approval certificate. |
| Packaging | Box |
| VPE length | 186 mm |
| VPE width | 118 mm |
| VPE height | 90 mm |
| Notes | End plate required Clearance and creepage distances to other components must be devised in accordance with the relevant application standard. This can be achieved in the device by full encapsulation or by the use of additional spacer plates. Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. Colours: SW = black; GN/YL = green/yellow; GY = grey Additional variants on request Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months |