FieldPower® contact element, AC, IP20, Insulation displacement connection (IDC), PUSH IN, Number of poles : 5
Technical Specifications:
| Depth | 54 mm |
| Depth (inches) | 2.126 inch |
| Height | 139.5 mm |
| Height (inches) | 5.492 inch |
| Width | 61.5 mm |
| Width (inches) | 2.421 inch |
| Net weight | 196 g |
| Storage temperature | -40 °C…85 °C |
| Operating temperature | -40 °C…55 °C |
| RoHS Compliance Status | Compliant without exemption |
| REACH SVHC | No SVHC above 0.1 wt% |
| Connection data – contact element power bus | Wire connection method: Insulation displacement connection (IDC) Blade size of operating tool: 0.6 x 3.5 mm Number of poles: 5 Conductor connection cross-section, solid, max.: 6 mm² Conductor connection cross-section, solid, min.: 1.5 mm² Conductor connection cross-section, stranded, max.: 6 mm² Conductor connection cross-section, stranded, min.: 2.5 mm² Conductor connection cross-section, finely stranded, max.: 6 mm² Conductor connection cross-section, finely stranded, min.: 2.5 mm² Conductor connection cross-section, finest stranded, max.: 6 mm² Conductor connection cross-section, finest stranded, min.: 2.5 mm² |
| Connection data – contact element Branch / Feed-in | Wire connection method: PUSH IN Blade size of operating tool: 0.6 x 3.5 mm Number of poles: 5 Conductor connection cross-section, solid, max.: 6 mm² Conductor connection cross-section, solid, min.: 0.5 mm² Conductor connection cross-section, stranded, max.: 6 mm² Conductor connection cross-section, stranded, min.: 0.5 mm² Conductor connection cross-section, finely stranded, max.: 10 mm² Conductor connection cross-section, finely stranded, min.: 0.5 mm² Conductor connection cross-section, finest stranded, max.: 6 mm² Conductor connection cross-section, finest stranded, min.: 0.5 mm² Conductor connection cross-section with wire end ferrule: Type of wire end ferrule: 12 mm with plastic collar Standard: DIN 46228/1 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: 12 mm with plastic collar Standard: DIN 46228/4 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: 8 mm with plastic collar Standard: DIN 46228/1 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: 8 mm with plastic collar Standard: DIN 46228/4 Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² Type of wire end ferrule: Twin wire-end ferrules Cross-section, min.: 0.5 mm² Cross-section, max.: 6 mm² |
| Insulating material | Polyamide |
| Silicone | No |
| Colour | grey |
| Protection degree | IP20 |
| UL 94 flammability rating | V-0 |
| Can be coded | Yes |
| Voltage type | AC |
| Number of poles | 5 |
| Number of connections / pole | 1 |
| Wire connection method | Insulation displacement connection (IDC) PUSH IN |
| Type of connection 2 | FieldPower® plug PTS 4, PTDS4 |
| Rated data acc. to IEC for contact element | Voltage type: AC Number of phases: 3 Standard: IEC 60947-7-1, IEC 60947-7-2 Rated voltage: 800 V Rated impulse withstand voltage: 8 kV Rated current (3 loaded poles): 41 A Rated current (4 loaded poles): 25 A |
| Rated data acc. to UL for contact element | Standard: UL 1059 Note: for use with UL-listed TC-ER cables Conductor connection cross-section, AWG, max.: AWG 10 Conductor connection cross-section, AWG, min.: AWG 14 Rated voltage: 600 V Rated current: 30 A |