Technical Specifications:

Depth 91 mm
Depth (inches) 3.583 inch
Height 104.5 mm
Height (inches) 4.114 inch
Width 72 mm
Width (inches) 2.835 inch
Net weight 680 g
Storage temperature -40 °C…85 °C
Operating temperature -40 °C…85 °C
Humidity 5 – 95% rel. humidity
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Ambient temperature (operational), max. 85 °C
Rated Voltage UN 240 V
VPR (N-PE) 900 V
MCOV (L/N-PE) 300 V
SCCR 150 kA
In 20 kA
Category SPD TYPE 1CA
Ambient temperature (operational), min. -40 °C
Certificate No. (cURus) E3542610000
MODE all modes
VPR (L-L) 1,800 V
VPR (L-N) 1,800 V
VPR (L-PE) 900 V
Voltage type AC
Connection type PUSH IN
Cross-section for connected wire, solid core, max. 1.5 mm²
Cross-section for connected wire, solid core, min. 0.14 mm²
Stripping length 8 mm
Colour orange black
Design Installation housing; 4TE Insta IP 20
Operating altitude ≤ 4000 m
Optical function display green = OK; red = arrester is defective – replace
Protection degree IP20 in installed state
Rail TS 35
Segment Power distribution
UL 94 flammability rating V-0
Version Surge protection with remote contact
Pollution severity 2
Surge voltage category III
Discharge current Imax (8/20µs) wire-PE 50 kA
Discharge current In (8/20µs) wire-PE 20 kA
Energy coordination (≤10 m) Type I Type II Type III
Follow-on current extinguishing capability Ifi Not available due for technical reasons
Frequency range, max. 60 Hz
Frequency range, min. 50 Hz
Fuse No Fuse neccessary ≤315 A gG 250 A gG @50 kA Isccr 315 A gG @25 kA Isccr
Integrated back-up fuse No
Leakage current at Un 0.6 mA
Lightning test current Iimp (10/350 µs) (L-PE) 12.5 kA
Low voltage network TN-C-S TN-S
Mains voltage 230 V / 400 V
Max. continuous voltage, Uc (AC) 300 V
Number of poles 3
Protection level Up at IN (L/N-PE) ≤ 1.5 kV
Rated voltage (AC) 230 V
Requirements category acc. to IEC 61643-11 Type I Type II
Requirements class, acc. to EN 61643-11 T1 T2
Response time ≤ 25 ns
Short-circuit current rating ISCCR 50 kA
Signalling contact 250 V 1A 1CO
Standards IEC61643-11, EN61643-11 UL 1449
Temporary surge voltage (over-voltage) – TOV 337 V
Voltage type AC
Stripping length 15 mm
Wire connection method Screw connection
Type of connection Screw connection
Stripping length, rated connection 15 mm
Tightening torque, min. 2 Nm
Tightening torque, max. 4.5 Nm
Clamping range, rated connection 16 mm²
Clamping range, min. 4 mm²
Clamping range, max. 35 mm²
Wire cross-section, solid, min. 1.5 mm²
Wire cross-section, solid, max. 35 mm²
Wire connection cross section, finely stranded, min. 1.5 mm²
Wire connection cross section, finely stranded, max. 25 mm²
Connection cross-section, stranded, min. 1.5 mm²
Connection cross-section, stranded, max. 35 mm²
Voltage type AC
Number of poles 3
Protection degree IP20 in installed state
Colour orange black
Time interval 5 years
Product information For use in DC applications, please use the fuse of SIBA Type NH2XL aR/aSF DC 1500 V