Current monitoring, Input current: 0…1 A AC/ 0…5 A AC/ 0…10 A AC, Output : 0-20 mA, 0-10 V
Technical Specifications:
| Depth | 92.4 mm |
| Depth (inches) | 3.638 inch |
| Width | 22.5 mm |
| Width (inches) | 0.886 inch |
| Length | 72 mm |
| Length (inches) | 2.835 inch |
| Net weight | 76.9 g |
| Storage temperature | -20 °C…70 °C |
| Operating temperature | 0 °C…70 °C |
| Humidity at operating temperature | 0…95 % (no condensation) |
| SIL in compliance with IEC 61508 | None |
| MTTF | 533 a |
| RoHS Compliance Status | Compliant with exemption |
| RoHS Exemption (if applicable/known) | 7a, 7cI |
| REACH SVHC | Lead 7439-92-1 |
| SCIP | b25f3b7c-b874-4a4e-a8b2-4f423a7e2a65 |
| Input current | 0…1 A AC/ 0…5 A AC/ 0…10 A AC |
| Input frequency | 50…60Hz |
| Number of inputs | 1 |
| Load impedance current | ≤ 600 Ω |
| load impedance voltage | ≥ 1 kΩ |
| Number of outputs | 1 |
| Offset current | max. 100 µA |
| Offset voltage | max. 0.05 V |
| Output current | 0(4)…20 mA |
| Output signal limit | Approx. 13 V or 24 mA |
| Output voltage, note | 0…10 V |
| Max. switching voltage, AC | 0 V |
| Rated switching current | 0.1 A |
| Accuracy | 0.5 % FSR |
| Configuration | DIP switch |
| Current consumption | 40 mA @ IOUT = 20 mA |
| Nominal power consumption | 1.5 VA |
| Protection degree | IP20 |
| Rail | TS 35 |
| Step response time | typ. 700 ms |
| Temperature coefficient | ≤ 200 ppm/K |
| Voltage supply | 24 V DC ± 10 % |
| EMC standards | EN 55011 EN 61000-6 |
| Galvanic isolation | 2-way isolator |
| Impulse withstand voltage | 6 kV |
| Insulation voltage | 4 kVeff / 5 s |
| Pollution severity | 2 |
| Rated voltage | 300 V |
| Surge voltage category | III |
| Wire connection method | Screw connection |
| Type of connection | Screw connection |
| Clamping range, rated connection | 2.5 mm² |
| Clamping range, min. | 0.5 mm² |
| Clamping range, max. | 2.5 mm² |
| Product information | This product will soon be replaced by a new product.Please do not use with new systems. Please contact our technical support. |
| Long specification | Monitoring component for AC currents up to 10A with standard signal outputand electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents0…1 A / 0…5 A / 0…10 A. Standardised analogue current/voltage signalsare available on the output side. Input and output ranges can be adjusted via DIP switches.The 24 VDC power is supplied over the output circuit.The input and outputs are designed with 6 kV of electrical isolation.Add-on housing for TS35 rail mountingDimensions: L/W/H 72/ 22.5/ 92.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20 Input 0…1 A / 0…5 A / 0…10 A AC switchable 50 / 60 HzVoltage of measuring circuit 250 V ACOutput 0(4)…20 mA / 0…10 VLoad resistance 1 kOhm / voltageTransmission error < 0,5% v. E. Temperature coefficient 200 ppm / KStep response time typ. 700 msAuxiliary power 24 VDC +/- 10 % via output circuitAmbient temperature range 0 °C…+50 °C Secure isolation EN 50178, 2-way isolation up to 6 kVTest voltage 4 kV input against outputRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULusType WAS1 CMA 1/5/10A ac |
| Short specification | Monitoring component for AC currents up to 10A with standard signal output and electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents 0…1 A / 0…5 A / 0…10 A. Standardised analogue current/voltage signals are available on the output side. Input and output ranges can be adjusted via DIP switches. The 24 VDC power is supplied over the output circuit. The input and outputs are designed with 6 kV of electrical isolation.n> |





Reviews
There are no reviews yet.