Fuse terminal, Screw connection, black, 4 mm², 10 A, 250 V, Number of connections: 2, Number of levels: 1, TS 35, TS 32

Technical Specifications:

Depth 53.5 mm
Depth (inches) 2.106 inch
Height 81.6 mm
Height (inches) 3.213 inch
Width 9.1 mm
Width (inches) 0.358 inch
Net weight 20.275 g
Storage temperature -25 °C…55 °C
Ambient temperature -5 °C…40 °C
Continuous operating temp., min. -50 °C
Continuous operating temp., max. 120 °C
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 7cI
REACH SVHC No SVHC above 0.1 wt%
Material Wemid
Colour black
UL 94 flammability rating V-0
Version Screw connection Fuse isolator with LED One end without connector
End cover plate required Yes
Number of potentials 1
Number of levels 1
Number of clamping points per level 2
Number of potentials per tier 1
Levels cross-connected internally No
PE connection No
Rail TS 35 TS 32
N-function No
PE function No
PEN function No
Wire connection cross section, finely stranded with wire-end ferrules DIN 46228/1, 2 clampable wires, max. 1.5 mm²
Wire connection cross section, finely stranded with wire-end ferrules DIN 46228/1, 2 clampable wires, min. 0.5 mm²
Wire connection cross section, finely stranded, two clampable wires, min. 0.5 mm²
Wire cross-section, finely stranded, two clampable wires, max. 1.5 mm²
Number of similar terminals 1
Open sides right
Type of mounting Snap-on
Connection type, additional connection Screw connection
Blade size 0.6 x 3.5 mm
Clampable conductor Connection specification: Screw connection Cross-section for conductor connection: Type: solid, H05(07) V-U min.: 0.5 mm² max.: 6 mm² nominal: 4 mm² wire end ferrule: Stripping length: min.: 11 mm max.: 11 mm nominal: 11 mm Tightening torque: min.: 0.5 Nm max.: 0.8 Nm Connection specification: Screw connection Cross-section for conductor connection: Type: stranded, H07V-R min.: 1.5 mm² max.: 6 mm² nominal: 4 mm² wire end ferrule: Stripping length: min.: 11 mm max.: 11 mm nominal: 11 mm Tightening torque: min.: 0.5 Nm max.: 0.8 Nm Connection specification: Screw connection Cross-section for conductor connection: Type: flexible, H05(07) V-K min.: 0.5 mm² max.: 6 mm² nominal: 4 mm² wire end ferrule: Stripping length: min.: 11 mm max.: 11 mm nominal: 11 mm Tightening torque: min.: 0.5 Nm max.: 0.8 Nm
Clamping range, max. 6 mm²
Clamping range, min. 0.5 mm²
Clamping screw M 3
Connection cross-section, stranded, max. 6 mm²
Connection cross-section, stranded, min. 1.5 mm²
Connection direction on side
Gauge to IEC 60947-1 A3
Number of connections 2
Stripping length 10 mm
Tightening torque, max. 0.8 Nm
Tightening torque, min. 0.5 Nm
Torque level with DMS electric screwdriver 2
Type of connection Screw connection
Type of connection 2 Screw connection
Wire connection cross section AWG, max. AWG 10
Wire connection cross section AWG, min. AWG 22
Wire connection cross section, finely stranded, max. 6 mm²
Wire connection cross section, finely stranded, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max. 4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min. 0.5 mm²
Wire connection cross-section, solid core, max. 6 mm²
Wire connection cross-section, solid core, min. 0.5 mm²
Certificate No. (CSA) 200039-1575489
Wire cross section max. (CSA) 10 AWG
Wire cross section min. (CSA) 30 AWG
TS 35 offset 25 mm
Type of voltage for indicator AC/DC
Cartridge fuse 6.3 x 32 mm (1/4 x 1 1/4″)
Display Red LED
Fuse holder (cartridge holder) Pivoting
Operating voltage, max. 250 V
Power loss for overload and short-circuit protection for a composite arrangement 1.6 W at 1.0 A @ 41°C
Power loss for short-circuit protection only for a composite arrangement 2.5 W at 2.5 A @ 68°C
Power loss for short-circuit protection only for an individual arrangement 4.0 W at 10 A @ 55°C
Type of voltage for indicator AC/DC
Rail TS 35 TS 32
Standards IEC 60947-7-3
Wire connection cross section AWG, max. AWG 10
Wire connection cross section AWG, min. AWG 22
Rated cross-section 4 mm²
Rated voltage 250 V
Rated voltage to adjoining terminal 500 V
Rated DC voltage 250 V
Rated current 10 A
Current at maximum wires 10 A
Standards IEC 60947-7-3
Volume resistance according to IEC 60947-7-x 1 mΩ
Rated impulse withstand voltage 6 V
Power loss in accordance with IEC 60947-7-x 1.02 W
Certificate No. (cURus) E60693
Conductor size Factory wiring max. (cURus) 10 AWG
Conductor size Factory wiring min. (cURus) 30 AWG
Conductor size Field wiring max. (cURus) 10 AWG
Conductor size Field wiring min. (cURus) 30 AWG
Product information The voltage depends on the selected fuse element or the selected indicator light