Weidmueller ZDK 4-2 PE

Request a price

ZDK 4-2 PE

SKU: 8671050000.0 Category: Brand:

Z-series, PE terminal, Rated cross-section: 4 mm², Tension-clamp connection, green

Technical Specifications:

Depth 60 mm
Depth (inches) 2.362 inch
Depth including DIN rail 61 mm
Height 77.6 mm
Height (inches) 3.055 inch
Width 6.1 mm
Width (inches) 0.24 inch
Net weight 21.595 g
Storage temperature -25 °C…55 °C
Ambient temperature -5 °C…40 °C
Continuous operating temp., min. -60 °C
Continuous operating temp., max. 130 °C
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Material Wemid
Colour Green/yellow
UL 94 flammability rating V-0
Version Tension-clamp connection With PE connection One end without connector
End cover plate required Yes
Number of levels 2
Number of clamping points per level 2
Levels cross-connected internally Yes
PE connection Yes
PEN function No
Explosion-tested version No
Open sides right
Type of mounting TS 35
Connection type, additional connection Tension-clamp connection
Blade size 0.6 x 3.5 mm
Clamping range, max. 6 mm²
Clamping range, min. 0.13 mm²
Connection cross-section, stranded, max. 6 mm²
Connection direction Inclined / angled
Gauge to IEC 60947-1 A3
Number of connections 4
Stripping length 10 mm
Tube length for twin wire-end ferrule Tube length: min.: 8 mm max.: 12 mm Cross-section for conductor connection: nominal: 0.5 mm² Tube length: min.: 8 mm max.: 12 mm Cross-section for conductor connection: nominal: 0.75 mm²
Tube length for wire-end ferrule with plastic collar DIN 46228/4 Tube length: min.: 8 mm max.: 10 mm Cross-section for conductor connection: nominal: 0.5 mm² Tube length: min.: 6 mm max.: 12 mm Cross-section for conductor connection: nominal: 0.75 mm² Tube length: min.: 6 mm max.: 12 mm Cross-section for conductor connection: nominal: 1 mm² Tube length: min.: 8 mm max.: 12 mm Cross-section for conductor connection: nominal: 1.5 mm² Tube length: min.: 8 mm max.: 12 mm Cross-section for conductor connection: nominal: 2.5 mm² Tube length: min.: 10 mm max.: 12 mm Cross-section for conductor connection: nominal: 4 mm²
Tube length for wire-end ferrule without plastic collar DIN 46228/1 Tube length: nominal: 10 mm Cross-section for conductor connection: nominal: 0.5 mm² Tube length: nominal: 10 mm Cross-section for conductor connection: nominal: 0.75 mm² Tube length: nominal: 10 mm Cross-section for conductor connection: nominal: 1 mm² Tube length: min.: 10 mm max.: 12 mm Cross-section for conductor connection: nominal: 1.5 mm² Tube length: min.: 10 mm max.: 12 mm Cross-section for conductor connection: nominal: 2.5 mm² Tube length: nominal: 12 mm Cross-section for conductor connection: nominal: 4 mm²
Type of connection Tension-clamp connection
Wire connection cross section AWG, max. AWG 12
Wire connection cross section AWG, min. AWG 26
Wire connection cross section, finely stranded, max. 4 mm²
Wire connection cross section, finely stranded, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max. 4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 4 mm²
Wire connection cross-section, solid core, max. 6 mm²
Wire connection cross-section, solid core, min. 0.5 mm²
Certificate No. (CSA) 200039-1236167
Wire cross section max. (CSA) 10 AWG
Wire cross section min. (CSA) 26 AWG
Standards IEC 60947-7-2
Wire connection cross section AWG, max. AWG 12
Wire connection cross section AWG, min. AWG 26
Rated cross-section 4 mm²
Rated voltage 800 V
Rated voltage to adjoining terminal 800 V
Rated DC voltage 800 V
Rated current 32 A
Standards IEC 60947-7-2
Volume resistance according to IEC 60947-7-x 1 mΩ
Rated impulse withstand voltage 8 kV
Rated impulse withstand voltage to adjacent terminal 8 kV
Power loss in accordance with IEC 60947-7-x 1.02 W
Pollution severity 3
Certificate No. (UR) E60693
Conductor size Factory wiring max. (UR) 10 AWG
Conductor size Factory wiring min. (UR) 26 AWG
Conductor size Field wiring max. (UR) 10 AWG
Conductor size Field wiring min. (UR) 26 AWG

Reviews

There are no reviews yet.

Be the first to review “Weidmueller ZDK 4-2 PE”

Your email address will not be published. Required fields are marked *