Weidmueller ZDUB 2.5-2/2AN/DM

Request a price

ZDUB 2.5-2/2AN/DM

SKU: 1704350000.0 Category: Brand:

Z-series, Feed-through terminal, Rated cross-section: 2.5 mm², Tension-clamp connection, dark beige, Direct mounting

Technical Specifications:

Depth 24 mm
Depth (inches) 0.945 inch
Height 33.5 mm
Height (inches) 1.319 inch
Width 5.1 mm
Width (inches) 0.201 inch
Net weight 3.72 g
Storage temperature -25 °C…55 °C
Ambient temperature -5 °C…40 °C
Continuous operating temp., min. -50 °C
Continuous operating temp., max. 120 °C
RoHS Compliance Status Compliant without exemption
REACH SVHC No SVHC above 0.1 wt%
Product Carbon Footprint Cradle to gate: 0.043 kg CO2 eq.
Material Wemid
Colour dark beige
UL 94 flammability rating V-0
Certificate No. (ATEX) DEMKO16ATEX1808U
Certificate No. (IECEX) IECEXULD16.0036U
Max. voltage (ATEX) 550 V
Current (ATEX) 21 A
Wire cross section max. (ATEX) 2.5 mm²
Max. voltage (IECEX) 550 V
Current (IECEX) 21 A
Wire cross section max. (IECEX) 2.5 mm²
Marking EN 60079-7 Ex eb II C Gb
Ex 2014/34/EU label II 2 G D
Version Tension-clamp connection can only be bridged at the clamping point One end without connector
End cover plate required Yes
Number of potentials 1
Number of levels 1
Number of clamping points per level 2
Number of potentials per tier 1
Levels cross-connected internally No
PE connection No
Rail TS 35
Explosion-tested version Yes
Installation advice Direct mounting
Open sides right
Type of mounting Direct mounting
Connection type, additional connection Tension-clamp connection
Blade size 0.6 x 3.5 mm
Clamping range, max. 4 mm²
Clamping range, min. 0.13 mm²
Connection cross-section, stranded, max. 4 mm²
Connection cross-section, stranded, min. 0.5 mm²
Connection direction top
Gauge to IEC 60947-1 A2
Number of connections 2
Stripping length 10 mm
Tube length for wire-end ferrule with plastic collar DIN 46228/4 Tube length: min.: 6 mm max.: 10 mm Cross-section for conductor connection: nominal: 0.5 mm² Tube length: min.: 6 mm max.: 10 mm Cross-section for conductor connection: nominal: 0.75 mm² Tube length: min.: 6 mm max.: 10 mm Cross-section for conductor connection: nominal: 1 mm² Tube length: min.: 8 mm max.: 10 mm Cross-section for conductor connection: nominal: 1.5 mm² Tube length: nominal: 8 mm Cross-section for conductor connection: nominal: 2.5 mm²
Tube length for wire-end ferrule without plastic collar DIN 46228/1 Tube length: nominal: 10 mm Cross-section for conductor connection: nominal: 0.5 mm² Tube length: nominal: 10 mm Cross-section for conductor connection: nominal: 0.75 mm² Tube length: nominal: 10 mm Cross-section for conductor connection: nominal: 1 mm² Tube length: nominal: 10 mm Cross-section for conductor connection: nominal: 1.5 mm² Tube length: nominal: 10 mm Cross-section for conductor connection: nominal: 2.5 mm²
Type of connection Tension-clamp connection
Wire connection cross section AWG, max. AWG 12
Wire connection cross section AWG, min. AWG 26
Wire connection cross section, finely stranded, max. 2.5 mm²
Wire connection cross section, finely stranded, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max. 1.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 0.5 mm²
Wire connection cross-section, solid core, max. 4 mm²
Wire connection cross-section, solid core, min. 0.5 mm²
Certificate No. (CSA) 12400-379
Current size C (CSA) 25 A
Voltage size C (CSA) 600 V
Wire cross section max. (CSA) 12 AWG
Wire cross section min. (CSA) 26 AWG
TS 15 offset 17 mm
Installation advice Direct mounting
Rail TS 35
Standards IEC 60947-7-1
Wire connection cross section AWG, max. AWG 12
Wire connection cross section AWG, min. AWG 26
Rated cross-section 2.5 mm²
Rated voltage 800 V
Rated DC voltage 800 V
Rated current 24 A
Current at maximum wires 30 A
Standards IEC 60947-7-1
Volume resistance according to IEC 60947-7-x 1.33 mΩ
Rated impulse withstand voltage 8 kV
Power loss in accordance with IEC 60947-7-x 0.77 W
Pollution severity 3
Certificate No. (cURus) E60693
Conductor size Factory wiring max. (cURus) 12 AWG
Conductor size Factory wiring min. (cURus) 26 AWG
Conductor size Field wiring max. (cURus) 12 AWG
Conductor size Field wiring min. (cURus) 26 AWG
Current size C (cURus) 20 A
Voltage size C (cURus) 600 V