Supply terminal, Tension-clamp connection, 16 mm², 800 V, 76 A, blue
Technical Specifications:
| Depth | 50.5 mm |
| Depth (inches) | 1.988 inch |
| Depth including DIN rail | 51.5 mm |
| Height | 61.5 mm |
| Height (inches) | 2.421 inch |
| Width | 14 mm |
| Width (inches) | 0.551 inch |
| Net weight | 24.904 g |
| Storage temperature | -25 °C…55 °C |
| Ambient temperature | -5 °C…40 °C |
| Continuous operating temp., min. | -50 °C |
| Continuous operating temp., max. | 120 °C |
| RoHS Compliance Status | Compliant without exemption |
| REACH SVHC | No SVHC above 0.1 wt% |
| Material | Wemid |
| Colour | blue |
| UL 94 flammability rating | V-0 |
| Version | Tension-clamp connection for plug-in cross-connector in closed state |
| End cover plate required | No |
| Number of potentials | 1 |
| Number of levels | 1 |
| Number of clamping points per level | 1 |
| Levels cross-connected internally | No |
| PE connection | No |
| Rail | TS 35 |
| Explosion-tested version | No |
| Number of similar terminals | 1 |
| Open sides | closed |
| Type of mounting | Snap-on |
| Connection type, additional connection | Tension-clamp connection |
| Blade size | 1.0 x 5.5 mm |
| Clamping range, max. | 25 mm² |
| Clamping range, min. | 1.5 mm² |
| Connection cross-section, stranded, max. | 25 mm² |
| Connection cross-section, stranded, min. | 16 mm² |
| Connection direction | Inclined / angled |
| Gauge to IEC 60947-1 | A7 |
| Number of connections | 1 |
| Stripping length | 18 mm |
| Type of connection | Tension-clamp connection |
| Wire connection cross section AWG, max. | AWG 4 |
| Wire connection cross section AWG, min. | AWG 14 |
| Wire connection cross section, finely stranded, max. | 16 mm² |
| Wire connection cross section, finely stranded, min. | 1.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max. | 16 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min. | 1.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. | 16 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. | 1.5 mm² |
| Wire connection cross-section, solid core, max. | 10 mm² |
| Wire connection cross-section, solid core, min. | 1.5 mm² |
| Certificate No. (CSA) | 200039-1152892 |
| Current size C (CSA) | 65 A |
| Voltage size C (CSA) | 600 V |
| Wire cross section max. (CSA) | 4 AWG |
| Wire cross section min. (CSA) | 14 AWG |
| Rail | TS 35 |
| Standards | In accordance with IEC 60947-7-1 |
| Wire connection cross section AWG, max. | AWG 4 |
| Wire connection cross section AWG, min. | AWG 14 |
| Rated cross-section | 16 mm² |
| Rated voltage | 800 V |
| Rated DC voltage | 800 V |
| Rated current | 76 A |
| Current at maximum wires | 76 A |
| Standards | In accordance with IEC 60947-7-1 |
| Volume resistance according to IEC 60947-7-x | 0.42 mΩ |
| Rated impulse withstand voltage | 6 kV |
| Power loss in accordance with IEC 60947-7-x | 2.43 W |
| Pollution severity | 3 |
| Certificate No. (UR) | E60693 |
| Conductor size Factory wiring max. (UR) | 4 AWG |
| Conductor size Factory wiring min. (UR) | 14 AWG |
| Conductor size Field wiring max. (UR) | 4 AWG |
| Conductor size Field wiring min. (UR) | 14 AWG |
| Current size C (UR) | 65 A |
| Voltage size C (UR) | 600 V |





Reviews