Z-series, Feed-through terminal, Rated cross-section: 2.5 mm², Tension-clamp connection, dark beige
Technical Specifications:
| Depth | 34.5 mm |
| Depth (inches) | 1.358 inch |
| Depth including DIN rail | 35 mm |
| Height | 71.5 mm |
| Height (inches) | 2.815 inch |
| Width | 5.1 mm |
| Width (inches) | 0.201 inch |
| Net weight | 7.46 g |
| Storage temperature | -25 °C…55 °C |
| Ambient temperature | -5 °C…40 °C |
| Continuous operating temp., min. | -50 °C |
| Continuous operating temp., max. | 120 °C |
| RoHS Compliance Status | Compliant without exemption |
| REACH SVHC | No SVHC above 0.1 wt% |
| Material | Wemid |
| Colour | dark beige |
| UL 94 flammability rating | V-0 |
| Version | 2 tension-clamp connections – 1 plug-in connection pluggable |
| End cover plate required | Yes |
| Number of potentials | 1 |
| Number of levels | 1 |
| Number of clamping points per level | 3 |
| Number of potentials per tier | 1 |
| Levels cross-connected internally | No |
| PE connection | No |
| Rail | TS 35 |
| PE function | No |
| Explosion-tested version | No |
| Open sides | right |
| Type of mounting | Snap-on |
| Conductor cross-section, flexible plus plastic collar DIN 46228/1, further connection, max. | 2.5 mm² |
| Connection type, additional connection | pluggable |
| Blade size | 0.6 x 3.5 mm |
| Clamping range, max. | 4 mm² |
| Clamping range, min. | 0.13 mm² |
| Connection cross-section, stranded, max. | 4 mm² |
| Connection cross-section, stranded, min. | 0.5 mm² |
| Connection direction | top |
| Gauge to IEC 60947-1 | A2 |
| Number of connections | 3 |
| Stripping length | 10 mm |
| Tube length for wire-end ferrule with plastic collar DIN 46228/4 | Tube length: min.: 6 mm max.: 10 mm Cross-section for conductor connection: nominal: 0.5 mm² Tube length: min.: 6 mm max.: 12 mm Cross-section for conductor connection: nominal: 0.75 mm² Tube length: min.: 6 mm max.: 12 mm Cross-section for conductor connection: nominal: 1 mm² Tube length: min.: 8 mm max.: 12 mm Cross-section for conductor connection: nominal: 1.5 mm² Tube length: min.: 8 mm max.: 12 mm Cross-section for conductor connection: nominal: 2.5 mm² |
| Tube length for wire-end ferrule without plastic collar DIN 46228/1 | Tube length: nominal: 10 mm Cross-section for conductor connection: nominal: 0.5 mm² Tube length: nominal: 10 mm Cross-section for conductor connection: nominal: 0.75 mm² Tube length: nominal: 10 mm Cross-section for conductor connection: nominal: 1 mm² Tube length: min.: 10 mm max.: 12 mm Cross-section for conductor connection: nominal: 1.5 mm² Tube length: min.: 10 mm max.: 12 mm Cross-section for conductor connection: nominal: 2.5 mm² |
| Type of connection | Tension-clamp connection |
| Type of connection 2 | Plug-in connection |
| Wire connection cross section AWG, max. | AWG 26 |
| Wire connection cross section AWG, min. | AWG 12 |
| Wire connection cross section, finely stranded, max. | 4 mm² |
| Wire connection cross section, finely stranded, min. | 0.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max. | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min. | 0.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. | 0.5 mm² |
| Wire connection cross-section, solid core, max. | 4 mm² |
| Wire connection cross-section, solid core, min. | 0.5 mm² |
| Certificate number (cCSAus) | 154685-1460993 |
| Current size C (cCSAus) | 20 A |
| Current size D (cCSAus) | 5 A |
| Voltage size C (cCSAus) | 300 V |
| Voltage size D (cCSAus) | 600 V |
| Wire cross section max. (cCSAusX) | 12 AWG |
| Wire cross section min. (cCSAusX) | 26 AWG |
| Rail | TS 35 |
| Standards | In accordance with IEC 60947-7-1 |
| Wire connection cross section AWG, max. | AWG 26 |
| Wire connection cross section AWG, min. | AWG 12 |
| Rated cross-section | 2.5 mm² |
| Rated voltage | 500 V |
| Max. voltage of clamp support & pluggable system | 690 V |
| Rated DC voltage | 500 V |
| Rated current | 24 A |
| Current at maximum wires | 24 A |
| Standards | In accordance with IEC 60947-7-1 |
| Volume resistance according to IEC 60947-7-x | 1.33 mΩ |
| Rated impulse withstand voltage | 6 kV |
| Power loss in accordance with IEC 60947-7-x | 0.77 W |
| Pollution severity | 3 |
| Surge voltage category | III |
| Certificate No. (cURus) | E60693 |
| Conductor size Factory wiring max. (cURus) | 12 AWG |
| Conductor size Factory wiring min. (cURus) | 26 AWG |
| Conductor size Field wiring max. (cURus) | 12 AWG |
| Conductor size Field wiring min. (cURus) | 26 AWG |
| Current size C (cURus) | 20 A |
| Current size D (cURus) | 5 A |
| Voltage size C (cURus) | 300 V |
| Voltage size D (cURus) | 600 V |





Reviews