EX signal isolating converter, Ex-input: I,ϑ, Safe-output: 4-20mA, 2-channel, Input : Temperature, 4-20 mA, EX, Output : 4-20 mA, Safe
Technical Specifications:
| Depth | 113.6 mm |
| Depth (inches) | 4.472 inch |
| Height | 119.2 mm |
| Height (inches) | 4.693 inch |
| Width | 22.5 mm |
| Width (inches) | 0.886 inch |
| Net weight | 180 g |
| Storage temperature | -20 °C…85 °C |
| Operating temperature | -20 °C…60 °C |
| Humidity | 0…95 % (no condensation) |
| SIL PAPER | SIL certificate |
| SIL in compliance with IEC 61508 | 2 |
| MTBF | 111 a |
| RoHS Compliance Status | Compliant with exemption |
| RoHS Exemption (if applicable/known) | 7a, 7cI |
| REACH SVHC | Lead 7439-92-1 |
| SCIP | 2f6dd957-421a-46db-a0c2-cf1609156924 |
| Mounting position | horizontal or vertical |
| Rail | TS 35 |
| Type of mounting | Snap mounting support rail |
| Input current | 0…20 mA 4…20mA |
| Input resistance, current | 20 Ω + PTC 50 Ω |
| Line resistance in measuring circuit | ≤ 50 Ω |
| Sensor | 2-/3-/4-wire RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000 Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710 |
| Temperature input range | Configurable PT100: -200…+850 °C K: (-180…+1372 °C) L: (-200…+900 °C) N: (-180…+1300 °C) R: (-50…+1760 °C) S: (-50…+1760 °C) T: (-200…+400 °C) U: (-200…+600 °C) W3: (0…+2300 °C) W5: (0…+2300 °C) LR: (-200…+800 °C) PT200: -200…+850 °C PT1000: -200…+850 °C NI100: -60°C…+250 °C Ni120: -80 °C…+320 °C NI1000: -60°C…+250 °C B: +100…+1820 °C E: (-100…+1000 °C) J: (-100…+1200 °C) |
| Type | intrinsically safe circuit RTD, TC, DC (mA) |
| Influence of load resistance | ≤ 0.01% of span / 100 Ω |
| Load impedance current | ≤ 600 Ω |
| Output current | 0…23 mA, configurable: 0…20 / 4…20 / 20…0 / 20…4 mA configurable downscale (3.5 mA) ⁄ upscale (23 mA) @ error |
| Output signal limit | 3.8…20.5 mA / 0…20.5 mA (dependent on range) |
| Type | active (as current source) or passive (as current sink) |
| Alarm function | Line interruption at the input Short circuit at input No supply voltage Device error |
| Continuous current | ≤ 0.5 A AC / 0.3 A DC (safe zone) ≤ 0,5 A AC / 1 A DC (zone 2) |
| Nominal switching voltage | ≤ 125 V AC / 110 V DC (safe area)≤ 32 V AC / 32 V DC (zone 2) |
| Power rating | ≤ 62.5 VA / 32 W (safe area)≤ 16 VA / 32 W (Zone 2) |
| Type | Status relay 1 NC (voltage-free) |
| Configuration | With FDT/DTM software Requires configuration adapter 8978580000 CBX200 USB |
| Humidity | 0…95 % (no condensation) |
| Operating altitude | ≤ 2000 m |
| Power consumption | ≤ 1.4 W |
| Protection degree | IP20 |
| Step response time | ≤ 400 ms (with current) ≤ 1 s (with temperature) |
| Type of connection | Screw connection |
| Voltage supply | 19.2…31.2 V DC |
| EMC standards | EN 61326-1 |
| Insulation voltage | 2.6 kV (input / output) |
| Rated voltage | 300 V |
| Standards | EN 61010-1 |
| Current I0 | 18.4 mA |
| Installation location | Device installed in safe area, zone 2 |
| Marking | II (1) G [Ex ia Ga] IIC/IIB/IIA II (1) D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I |
| Power P0 | 40 mW |
| Voltage U0 | 8.7 V DC |
| Description of the “safe state” | analogue Output ≤ 3.6 mA or output ≥ 21 mA |
| Device type | B |
| Diagnostic test interval | 30 s |
| Tproof | 3 a |
| Total failure rate for safe detected failures (λSD) | 0 FIT |
| Hardware fault tolerance (HFT) | 0 |
| Safety category | SIL 2 |
| Safe Failure Fraction (SFF) | 90 % |
| Mean Time To Repair (MTTR) | 24 h |
| Total failure rate for safe undetected failures (λSU) | 234 FIT |
| Total failure rate for dangerous detected failures (λDD) | 367 FIT |
| Total failure rate for dangerous undetected failures (λDU) | 61 FIT |
| Probability of outage PFH | 6.1 x 10-8 h-1 |
| Demand mode | High |
| Demand rate | 3,000 s |
| Demand response time | Signal input: <0.5 s (opto output) Temperature input: <1.1 s (opto output) |
| Average Probability of Failure on Demand (PFDavg) | 3.96 x 10-4 (Tproof = 1 year) 6.5 x 10-4 (Tproof = 2 years) 1.41 x 10-4 (Tproof = 5 years) |
| Type of connection | Screw connection |
| Tightening torque, min. | 0.4 Nm |
| Tightening torque, max. | 0.6 Nm |
| Clamping range, rated connection | 2.5 mm² |
| Clamping range, min. | 0.25 mm² |
| Clamping range, max. | 2.5 mm² |
| Wire connection cross section AWG, min. | AWG 26 |
| Wire connection cross section AWG, max. | AWG 12 |
| Time interval | 3 years |
| Long specification | Ex temperature transducer for RTD-/ TC temperature signals and DC current signals, 2-channel2-channel temperature transducer in 22.5 mm width with external power supply, for capturing and isolating RTD- / TC sensors and DC current signals 0(4)…20 mA from the Ex Zones 0, 1, 2. The outputs can be operated as either an active 0(4)…20 mA signal or as a passive 4…20 mA current loop. Status and error messages are available via a relay contact (NO). The component can be configured using standard FDT/DTM software. Add-on housing for TS35 rail mounting Dimensions: L/W/H 119.2/ 22.5/ 113.6Screw connection/ Nominal cross-section 2.5 mm2Protection degree: IP 20 Input / channel RTD: PT100, PT500, PT1000, Ni100, Ni120, Ni1000 TC- Type: B, E, J, K, N, R, S, T, U, L 0(4)…20 mA Output / channel active 0(4)…20 mA / 20..4 mA configurable passive 4…20 mA current loop 3.5…26 V DC Load / channel < 600 Ohm Accuracy < 0,1 % v.E. Temperature coefficient < 0,01% v.E./°C (Tu) Alarm output relay 1 NO contact 250 V AC / 30 V DC @ 2A safe zone 32 V AC @ 0.5 A/ 32 VDC @ 1 A Zone 2Auxiliary power 19…31.2 V DC Power loss approx. 3 W Ambient temperature range -20 °C…+60 °C Secure isolation EN 61010, 3-way isolation up to 2.6 kV AC/DC of all circuits against each otherWorking voltage 300 V AC/DC at overvoltage category II and pollution degree 2 Approvals cULus, ATEX IECEX, FM ATEX marking II 3 G ExnA nC IIC T4 ATEX characteristic data U0 = 8.7 V DC I0 = 18.4 mA DC P0 = 40 mW Type ACT20X-2HTI-2SAO-S |
| Short specification | Ex- temperature transducer for RTD-/ TC temperature signals and DC current signals, 2-channel2-channel temperature transducer in 22.5 mm width with external power supply,for capturing and isolating RTD/TC sensor and DC current signals (0(4)…20 mA) from Ex zones 0,1,2. The outputs can be operated in the safe zone either as an active signal (0(4)…20 mA) or as a passive 4…20 mA current loop. Status and error messages are available via a relay contact (NO).The component can be configured using standard FDT/DTM software. |